inspectionINSPECTION WORKSHEET (BINS-000970-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-000181-2017 Case Module:Permit Inspection Date:Fri Feb 15, 2019 Inspection Status:Partial Pass Inspector:Mark Smith Inspection Type:Building Framing Job Address:Parcel Number:21 Big Boom RD Queensbury, NY 12804 309.14-1-89.1 Contact Type Company Name Name Agent White, Richard Contractor Bette & Cring, LLC Applicant Bette & Cring, LLC Granted Permission Bette & Cring, LLC Architect Silvestri Architects, PC Primary Owner Exit 18 Development LLC Primary Owner Ed & Ed T Enterprises, LLC Engineer Hutchins Engineering Checklist Item Passed Comments Building Inspector Notes NO 2/11/19 Framing Not Approved - Preliminary Framing - Provide Dan Ryan's Inspection Report for the first floor framing inspection for walls and ceiling. - Provide floor and roof truss diagrams for framing inspections. - Engineer's approval on fastening of interior walls, corridor walls, and shear walls. Framer has used power actuated nails at all locations which is different from the approved plans. I spoke with Dan Ryan the engineer today while on site performing my inspection. Feb 15, 2019 Page (1) INSPECTION WORKSHEET (BINS-000970-2019) Checklist Item Passed Comments 2/15/19 Framing for first and second floor main hall ceiling approved. Third floor main hall ceiling not approved, it is still missing joist hangers.sound proofing insulation must be verified before sheet rock is installed. Framing NO 2/11/19 Framing Not Approved - Preliminary Framing - Provide Dan Ryan's Inspection Report for the first floor framing inspection for walls and ceiling. - Provide floor and roof truss diagrams for framing inspections. - Engineer's approval on fastening of interior walls, corridor walls, and shear walls. Framer has used power actuated nails at all locations which is different from the approved plans. I spoke with Dan Ryan the engineer today while on site performing my inspection. 2/15/19 first and second floor main hall ceiling only approved. Third floor is missing joist hangers. Sound proofing insulation must be verified before Sheetrock is installed. Truss Specification Provided NO Bracing Bridging NO Hurricane Clips/Uplift Screws/Nail Holes Filled NO Air Seal all Plates and Sills NO Air Seal All Registers at Floor NO Air Sealing all Joints Before Insulation NO Joist hangers NO Jack Posts Main Beams NO Exterior sheeting nailed properly NO Feb 15, 2019 Page (2) INSPECTION WORKSHEET (BINS-000970-2019) Checklist Item Passed Comments 12 O.C.NO Headroom 6 ft. 8 in.NO Notches Holes Bearing Walls NO Metal Strapping for Notches Top Plate NO Draft stopping 1,000 sq. ft. floor trusses NO Anchor Bolts 6 ft. or less on center NO Ice and water shield 24 inches from wall NO Soffits-Insulation Baffel NO Windows Habitable Space Bedrooms NO 24 in. (H)NO 20 in. (W)NO 5.7 sf above below grade NO 5.0 sf grade NO Design Professional Sign-off, if required NO Feb 15, 2019 Page (3) Smith, Mark (Inspector) INSPECTION WORKSHEET (BINS-000990-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-000181-2017 Case Module:Permit Inspection Date:Tue Feb 19, 2019 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Building Insulation Job Address:Parcel Number:21 Big Boom RD Queensbury, NY 12804 309.14-1-89.1 Contact Type Company Name Name Agent White, Richard Primary Owner Ed & Ed T Enterprises, LLC Granted Permission Bette & Cring, LLC Contractor Bette & Cring, LLC Primary Owner Exit 18 Development LLC Architect Silvestri Architects, PC Engineer Hutchins Engineering Applicant Bette & Cring, LLC Checklist Item Passed Comments Building Inspector Notes NO 2/19/19 Insulation Partial Approval- 3 1/2" Sound batts in corridor floors. - 1st Floor Corridor Ceiling North Wing only where 3 1/2" Sound Insulation is Installed before elevator. - 2nd Floor Corridor Ceiling at North & South Wings only where 3 1/2" Sound Insulation is installed. Window Sealing NO U Factors = .3 cfm for windows, .5 cfm for doors NO Feb 19, 2019 Page (1) INSPECTION WORKSHEET (BINS-000990-2019) Checklist Item Passed Comments Tyvek or Similar Exterior Sealant NO Proper Vent, Attic Vent NO Insulation Residential Check Commercial Check NO 2/19/19 Insulation Partial Approval- 3 1/2" Sound batts in corridor floors. - 1st Floor Corridor Ceiling North Wing only where 3 1/2" Sound Insulation is Installed before elevator. - 2nd Floor Corridor Ceiling at North & South Wings only where 3 1/2" Sound Insulation is installed. Blower Door Test NO Combustion Air Supply for Furnace NO Fresh air supply 3' from grade NO Duct Insulation - if required in unheated spaces NO Door / Window Sealed (No Insulation)NO Air Barrier behind Knee Walls NO Tub Shower R-20 with Vapor Barrier NO All Ductwork Sealed Return and Supply NO Duct Blaster Test for duct work, R-8 NO All Return Air Hard Duct Work NO House Wrap Taped at all Seams NO Feb 19, 2019 Page (2) O'Brien, John (Inspector) INSPECTION WORKSHEET (006386-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number: Inspection Date: Inspector: Case Module: Inspection Status: Inspection Type: CC-000181-2017 09/04/2018 John O'Brien Permit Passed Building Inspector Visit Job Address:Parcel Number:21 Big Boom RD Queensbury, NY 12804 309.14-1-89.1 Contact Type Company Name Name Primary Owner Exit 18 Development LLC , Primary Owner Ed & Ed T Enterprises, LLC , Agent White, Richard Contractor Bette & Cring, LLC , Architect Silvestri Architects, PC , Engineer Hutchins Engineering , Granted Permission Bette & Cring, LLC , Applicant Bette & Cring, LLC , Checklist Item Passed Comments Building Inspector Notes NO 9/4/18 As per my site visit I met Bette Cring project superintendent Fred Palma. Footings to begin next week the engineer Fred Dente will be on site this week to address soil compaction. I also discussed with Fred how to schedule inspections and giving at least 24 hours notice. I also explained to him if he will be pouring multiple days we will block a time slot for his inspection on those days. Fred provided the names of the subcontractors already hired for the project which are listed below. Subcontractors: Kingsley - Site Jag - Concrete Kohler - Framing Sep 04, 2018 Page (1) O'Brien, John (Inspector) INSPECTION WORKSHEET (BINS-007559-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-000181-2017Case Module:Permit Inspection Date:10/25/2018Inspection Status:Partial Pass Inspector:John O'BrienInspection Type:Building Foundation Job Address:21 Big Boom RDParcel Number:309.14-1-89.1 Queensbury, NY 12804 Contact TypeCompany NameName Primary OwnerEd & Ed T Enterprises, LLC\[Ed & Ed T Enterprises, LLC\] ApplicantBette & Cring, LLC\[Bette & Cring, LLC\] ArchitectSilvestri Architects, PC\[Silvestri Architects, PC\] EngineerHutchins Engineering\[Hutchins Engineering\] , ContractorBette & Cring, LLC\[Bette & Cring, LLC\] Primary OwnerExit 18 Development LLC\[Exit 18 Development LLC\] , AgentWhite, Richard Granted PermissionBette & Cring, LLC\[Bette & Cring, LLC\] Checklist ItemPassedComments Building Inspector NotesNO10/22/18 Foundation Walls Partial Approval - D7 to A4 10/25/18 Footings Partial Approval - Balance of North Front Elevation Footings - West Side Elevation Footings 10/25/18 Foundation Walls Partial Approval - Partial South Rear Elevation Frost Walls. 4 A.05 to 8 A0.5 10/25/18 Foundation Insulation & Backfill Partial Approval - C7 to A4 FootingsYESPartial only as per specs with 3 rows #5 continuous #4 J hooks tied in 32" OC 10/25/18 Footings Partial Approval - Balance of North Front Elevation Footings - West Side Elevation Footings PiersNO Monolithic SlabNO Foundation / WallpourYES10/22/18 Foundation Walls Partial Approval - D7 to A4 10/25/18 Foundation Walls Partial Approval - Partial South Rear Elevation Frost Walls. 4 A.05 to 8 A0.5 Oct 25, 2018Page (3) INSPECTION WORKSHEET (BINS-007559-2018) Checklist ItemPassedComments Reinforcement in PlaceYES10/25/18 Footings Partial Approval - Balance of North Front Elevation Footings - West Side Elevation Footings Reinforcement in PlaceYES10/25/18 Foundation Walls Partial Approval - Partial South Rear Elevation Frost Walls. 4 A.05 to 8 A0.5 Footing Dowels or Keyway in placeYES Foundation DampproofingNO Foundation WaterproofingNO Footing Drain Daylight or SumpNO Footing Drain Stone - 12 inch widthNO Footing Drain Stone - 6 inches above footingNO Footing Drain stone - 6 mil polyNO Backfill ApprovalNO10/25/18 Foundation Insulation & Backfill Partial Approval - C7 to A4 Plumbing Under SlabNO PVC / Cast / CopperNO Foundation Insulation Interior / ExteriorYES10/25/18 Foundation Insulation & Backfill Partial Approval - C7 to A4 Rough Grade 6 inch drop within 10 ft.NO Poly Under SlabNO O'Brien, John (Inspector) Oct 25, 2018Page (4) INSPECTION WORKSHEET (BINS-000232-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal CC-000181-2017Permit Case Number:Case Module: Wed Jan 9, 2019Partial Pass Inspection Date:Inspection Status: John O'BrienBuilding Foundation Inspector:Inspection Type: 21 Big Boom RD309.14-1-89.1 Job Address:Parcel Number: Queensbury, NY 12804 Contact TypeCompany NameName AgentWhite, Richard EngineerHutchins Engineering ArchitectSilvestri Architects, PC Granted PermissionBette & Cring, LLC Primary OwnerEd & Ed T Enterprises, LLC ApplicantBette & Cring, LLC Primary OwnerExit 18 Development LLC ContractorBette & Cring, LLC Checklist ItemPassedComments Jan 09, 2019Page (1) INSPECTION WORKSHEET (BINS-000232-2019) Checklist ItemPassedComments Building Inspector NotesNO10/22/18 Foundation Walls Partial Approval - D7 to A4 10/25/18 Footings Partial Approval - Balance of North Front Elevation Footings - West Side Elevation Footings 10/25/18 Foundation Walls Partial Approval - Partial South Rear Elevation Frost Walls. 4 A.05 to 8 A0.5 10/25/18 Foundation Insulation & Backfill Partial Approval - C7 to A4 11/14/18 Piers(Entry Canopy) & Interior Footings Not Ready! -Rescheduled for 1:00 PM tomorrow. 11/15/18 Entry Canopy Piers Approved 11/20/18 Interior Pier Footings & Floor Haunches Partial Approval. - Interior Pier Footings A9, A10, D9 and D10 - Interior Pier A.08/5 - Floor Haunches 12 thru 17 11/27/18 Interior Column Footings Partial Approval - 5 interior column Footings at 9, 10, & 11 lines 11/28/18 Interior Column and Pier Footings Partial Approval! - 2 Column Footings @ 8 Line - 2 Column Footings between 10.A & 11.A Lines - Pier Footing at 5 Line 12/4/18 Interior Footings & Monolithic Slab Partial Approval - Monolithic Slab to 8 line. - Interior Footings between 4 & 8 Lines - Exterior Footing @ 10A & E Line 1/3/19 Bond Beams Partial Approval - Elevator Shaft - Vertical Bars Verified at 48" oc - Bond beam Approved at 2nd floor (2-#4 bars continuous and corner bars installed) NOTE: Unable to verify bond beams with reinforcing in lieu of steel lintels at elevator door openings. The bond beams had already been grouted. The engineer will have to approve these locations not inspected by whatever means necessary to verify reinforcing was installed. The structural masonry (grout & reinforcing)needs to be inspected by the third party inspector also. Please make arrangements for future inspections. 1/7/19 Bond Beam Partial Approval - Second Floor elevator door openings and continuation of vertical reinforcing at 48" oc. 1/7/19 Bond Beam Partial Approval - Elevator Shaft Jan 09, 2019Page (2) INSPECTION WORKSHEET (BINS-000232-2019) Checklist ItemPassedComments - Bond beam Approved at 2nd floor 2 courses above elevator doors (2-#4 bars continuous and corner bars installed) 1/9/19 Bond Beams Approved - Elevator Complete FootingsYESPartial only as per specs with 3 rows #5 continuous #4 J hooks tied in 32" OC 10/25/18 Footings Partial Approval - Balance of North Front Elevation Footings - West Side Elevation Footings 10/30/18. Remainder of footings east wall rebar per plan 11/7/18 Elevator pit footing per plan 11/20/18 Interior Pier Footings & Floor Haunches Partial Approval. - Interior Pier Footings A9, A10, D9 and D10 - Interior Pier A.08/5 - Floor Haunches 12 thru 17 11/27/18 Interior Column Footings Partial Approval - 5 interior column Footings at 9, 10, & 11 lines 11/28/18 Interior Column and Pier Footings Partial Approval! - 2 Column Footings @ 8 Line - 2 Column Footings between 10.A & 11.A Lines - Pier Footing at 5 Line 12/4/18 Interior Footings & Monolithic Slab Partial Approval - Monolithic Slab to 8 line. - Interior Footings between 4 & 8 Lines - Exterior Footing @ 10A & E Line PiersYES11/15/18 Entry Canopy Piers Approved Monolithic SlabNO Jan 09, 2019Page (3) INSPECTION WORKSHEET (BINS-000232-2019) Checklist ItemPassedComments Reinforcement in PlaceYES10/25/18 Foundation Walls Partial Approval - Partial South Rear Elevation Frost Walls. 4 A.05 to 8 A0.5 11/15/18 Entry Canopy Piers Approved 1/3/19 Bond Beams Partial Approval - Elevator Shaft - Vertical Bars Verified at 48" oc - Bond beam Approved at 2nd floor (2-#4 bars continuous and corner bars installed) NOTE: Unable to verify bond beams with reinforcing in lieu of steel lintels at elevator door openings. The bond beams had already been grouted. The engineer will have to approve these locations not inspected by whatever means necessary to verify reinforcing was installed. The structural masonry (grout & reinforcing)needs to be inspected by the third party inspector also. Please make arrangements for future inspections. 1/7/19 Bond Beam Partial Approval - Second Floor elevator door openings and continuation of vertical reinforcing at 48" oc. 1/7/19 Bond Beam Partial Approval - Elevator Shaft - Bond beam Approved at 2nd floor 2 courses above elevator doors (2-#4 bars continuous and corner bars installed) 1/9/19 Bond Beams Approved - Elevator Complete Jan 09, 2019Page (4) INSPECTION WORKSHEET (BINS-000232-2019) Checklist ItemPassedComments Foundation / WallpourYES10/22/18 Foundation Walls Partial Approval - D7 to A4 10/25/18 Foundation Walls Partial Approval - Partial South Rear Elevation Frost Walls. 4 A.05 to 8 A0.5 10/30/18 7 to 11A rebar per plan 11/1/18. Front wall complete. East wall to laundry room 11/5/18 remainder of foundation wall 11/9/18 foundation wall for elevator pit 1/3/19 Bond Beams Partial Approval - Elevator Shaft - Vertical Bars Verified at 48" oc - Bond beam Approved at 2nd floor (2-#4 bars continuous and corner bars installed) NOTE: Unable to verify bond beams with reinforcing in lieu of steel lintels at elevator door openings. The bond beams had already been grouted. The engineer will have to approve these locations not inspected by whatever means necessary to verify reinforcing was installed. The structural masonry (grout & reinforcing)needs to be inspected by the third party inspector also. Please make arrangements for future inspections. 1/7/19 Bond Beam Partial Approval - Second Floor elevator door openings and continuation of vertical reinforcing at 48" oc. 1/7/19 Bond Beam Partial Approval - Elevator Shaft - Bond beam Approved at 2nd floor 2 courses above elevator doors (2-#4 bars continuous and corner bars installed) 1/9/19 Bond Beams Approved - Elevator Complete Jan 09, 2019Page (5) INSPECTION WORKSHEET (BINS-000232-2019) Checklist ItemPassedComments Reinforcement in PlaceYES10/25/18 Footings Partial Approval - Balance of North Front Elevation Footings - West Side Elevation Footings 11/1/18 rebar per plan 11/20/18 Interior Pier Footings & Floor Haunches Partial Approval. 12/7/18. Pier for canopy and for north end floor haunches - Interior Pier Footings A9, A10, D9 and D10 - Interior Pier A.08/5 - Floor Haunches 12 thru 17 11/27/18 Interior Column Footings Partial Approval - 5 interior column Footings at 9, 10, & 11 lines 11/28/18 Interior Column and Pier Footings Partial Approval! - 2 Column Footings @ 8 Line - 2 Column Footings between 10.A & 11.A Lines - Pier Footing at 5 Line 12/4/18 Interior Footings & Monolithic Slab Partial Approval - Monolithic Slab to 8 line. - Interior Footings between 4 & 8 Lines - Exterior Footing @ 10A & E Line Footing Dowels or Keyway in placeYES11/15/18 Entry Canopy Piers Approved Foundation DampproofingNO Foundation WaterproofingNO Footing Drain Daylight or SumpNO Footing Drain Stone - 12 inch widthNO Footing Drain Stone - 6 inches above footingNO Footing Drain stone - 6 mil polyNO Backfill ApprovalNO10/25/18 Foundation Insulation & Backfill Partial Approval - C7 to A4 Jan 09, 2019Page (6) INSPECTION WORKSHEET (BINS-000232-2019) Checklist ItemPassedComments Plumbing Under SlabNO11/9/18 plumbing under slab south side of building PVC / Cast / CopperNO Foundation Insulation Interior / ExteriorYES10/25/18 Foundation Insulation & Backfill Partial Approval - C7 to A4 10/29/18. Not ready 11/1/18 front entrance wall 11/5/18 remainder of front entrance wall interior 11/8/18 remainder of foundation insulation Rough Grade 6 inch drop within 10 ft.NO Poly Under SlabNO O'Brien, John (Inspector) Jan 09, 2019Page (7)