ResCheck Y
N
REScheck Software Version 4.6.4
. Certificate o , tri
: Compliance Certi ca e o a
ac �
Project Bardin Project n i TI c a
.0
Energy Code: 2015 IECC L �PR 1 S Z�191 g IV 2
rii) EC IE 11 V
Location: Lake George, New Yorka ;p go
Construction Type: Single-family �� � ®� JE�NS � Q 0
Project Type: New Construction BUILDING CODES �, M
Conditioned Floor Area: 2,804 ft2 _
Glazing Area 18%
CD I
Climate Zone: 6 (7377 HDD) 71 N
Permit Date: N
Permit Number: - O
N
Construction Site: Owner/Agent: Designer/Contractor: ;-,, CO
Randy Bardin Frank Jelley
NY NY
518-796-5611
Compliance: Passes using UA trade-off
Compliance: 0.0%Better Than Code Maximum UA: 488 Your UA: 488
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Ceiling 1: Flat Ceiling or Scissor Truss 1,985 49.0 0.0 0.026 52
Wall 1:Wood Frame, 16"o.c. 3,420 21.0 0.0 0.057 159
Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 489 0.260 127
Door 1: Glass 135 0.260 35
Basement Wall 1: Solid Concrete or Masonry 1,089 21.0 0.0 0.043 47
Wall height: 8.7'
Depth below grade: 7.5'
Insulation depth: 8.7'
Basement Wall 2:Wood Frame 1,080 21.0 0.0 0.060 65
Wall height: 8.7'
Depth below grade: 0.0'
Insulation depth: 8.7'
Mud Room Floor:All-Wood Joist/Tru5s ver Unconditioned Space - 95 30.0 0.0 0.033 3
Compliance Statement: The pi,,
p d—��'b;)itld'ing•design described here is consistent with the building plans,specifications, and other
calculations submitted with t e`perfxifi application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.4 and/ o cgmply with,the mandatory requi ents li to in th EScheck Inspection Checklist.
Frank i QC/4/
Name-Title ' < ' Si nature date
i/1¼Project Title: Bardin Project ` , Report date: 06/06/18
Data filename: C:\FJ\Arch Design\Ba di', :. din Project.rck Page 1 of 9
REScheck Software Version 4.6.4
Irv. Inspection Checklist
Energy Code: 2015 IECC
Requirements: 97.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
#fi Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and ❑Complies Requirement will be met.
103.2 documentation demonstrate ❑Does Not
[PR1]1 energy code compliance for the
building envelope.Thermal ['Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ii❑Complies Requirement will be met.
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]1 lighting and mechanical systems. ❑Not Observable
Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies Requirement will be met.
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR212 on loads calculated per ACCA Cooling: Cooling:
Manual J or other methods ❑Not Observable
approved by the code official. Btu/hr Btu/hr ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Bardin Project Report date: 06/06/18
Data filename: C:\FJ\Arch Design\Bardin\Bardin Project.rck Page 2 of 9
Section Plans Verified Field Verified
Foundation Inspection Value Value Complies? Comments/Assumptions
&Req.ID
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
[FO4]1 insulation R-value.Where interior R_ R- ❑Does Not
table for values.
insulation is used,verification
may need to occur during ❑Not Observable
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies Requirement will be met.
[FO5]1 insulation installed per ❑Does Not
manufacturer's instructions.
['Not Observable
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ElComplies See the Envelope Assemblies
[FO6]1 insulation depth of burial or "'Does Not table for values.
distance from top of wall.
❑Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ' ❑Complies Exception: Requirement is
[FO1l]2 to protect exposed exterior ❑Does Not not applicable.
insulation and extends a
minimum of 6 in. below grade. [Not Observable
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies Exception: Requirement is
[FO12]2 controls installed. ❑Does Not not applicable.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Bardin Project Report date: 06/06/18
Data filename: C:\FJ\Arch Design\Bardin\Bardin Project.rck Page 3 of 9
Section Plans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.3.6, ❑Not Observable
402.5 ❑Not Applicable
[FR2]1
303.1.3 U-factors of fenestration products" ❑Complies Requirement will be met.
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or
taken from the default table. ❑Not Observable
❑Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies Requirement will be met.
[FR2311 installed per manufacturer's ❑Does Not
instructions.
❑Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies Requirement will be met.
[FR20]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC [Not Observable
400 that do not exceed code ❑Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies Requirement will be met.
[FR16]z sealed at housing/interior finish ❑Does Not
and labeled to indicate <_2.0 cfm
leakage at 75 Pa. ['Not Observable
❑Not Applicable
403.2.1 Supply and return ducts in attics ❑Complies Requirement will be met.
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >=
R-6 where< 3 inches.Supply and [Not Observable
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.3.5 Building cavities are not used as ❑Complies Requirement will be met.
[FR15]3 ducts or plenums. ❑Does Not
['Not Observable
❑Not Applicable
403.4 HVAC piping conveying fluids R- R- ❑Complies Requirement will be met.
[FR17J2 above 105°F or chilled fluids ❑Does Not
below 55°F are insulated to>_R-
_; [Not Observable
3.
❑Not Applicable
403.4.1 Protection of insulation on HVAC ❑Complies Requirement will be met.
[FR24]1 piping. ElDoes Not
❑Not Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- ❑Complies Requirement will be met.
[FR18]2 >_R 3. ❑Does Not
❑Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are ❑Complies Requirement will be met.
[FR19)2 installed on all outdoor air ❑Does Not
intakes and exhausts.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Bardin Project Report date: 06/06/18
Data filename: C:\FJ\Arch Design\Bardin\Bardin Project.rck Page 4 of 9
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Bardin Project Report date: 06/06/18
Data filename: C:\FJ\Arch Design\Bardin\Bardin Project.rck Page 5 of 9
Section Plans Verified Field Verified
Insulation Inspection Value Value Complies? Comments/Assumptions
&Req.ID,
303.1 All installed insulation is labeled ❑Complies Requirement will be met.
[IN13]2 or the installed R-values ❑Does Not
provided. ❑Not Observable
❑Not Applicable
402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values.
[INi]1 ❑ Steel ❑ Steel ❑Not Observable
❑Not Applicable
303.2, Floor insulation installed per ,❑Complies Requirement will be met.
402.2.7 manufacturer's instructions and ❑Does Not
[IN2]1 in substantial contact with the
underside of the subfloor, or floor ❑Not Observable
framing cavity insulation is in ❑Not Applicable
contact with the top side of
sheathing,or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
402.1.1, Wall insulation R-value. If this is a; R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least l of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable
[IN3]1 exterior,the exterior insulation
requirement applies(FR10). ❑ Steel ID Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies Requirement will be met.
[IN4]1 manufacturer's instructions. ❑Does Not
['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Bardin Project Report date: 06/06/18
Data filename: C:\FJ\Arch Design\Bardin\Bardin Project.rck Page 6 of 9
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
&Req.ID
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2, ❑ Steel ❑ Steel ['Not Observable
402.2.E ❑Not Applicable
PPlicable
303.1.1.1, Ceiling insulation installed per ❑Complies Requirement will be met.
303.2 manufacturer's instructions. ElDoes Not
[FI2]1 Blown insulation marked every
300 ft2. ['Not Observable
❑Not Applicable
402.2.3 Vented attics with air permeable ❑Complies Requirement will be met.
[FI22]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. [Not Observable
❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies Requirement will be met.
[FI3]i insulation >_R-value of the ElDoes Not
adjacent assembly.
❑Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50= ❑Complies Requirement will be met.
[FI17]1 ach in Climate Zones 1-2,and ElDoes Not
<=3 ach in Climate Zones 3-8.
[Not Observable
❑Not Applicable
402.4.2 Wood-burning fireplaces have ElComplies
[FI812 tight fitting flue dampers and ❑Does Not
outdoor air for combustion.
[Not Observable
❑Not Applicable
403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies Exception:All ducts and air
[FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not handlers are located within
<=3 cfm/100 ft2 without air ['Not Observable conditioned space.
handler @ 25 Pa. For rough-in
tests,verification may need to ❑Not Applicable
occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ElComplies Exception:All ducts and air
[FI27]1 determine air leakage with ft2 ft2 ElDoes Not handlers are located within
either: Rough-in test:Total ['Not Observable conditioned space.
leakage measured with a
pressure differential of 0.1 inch ❑Not Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated ElComplies Requirement will be met.
[FI24]1 by manufacturer at<=2%of ElDoes Not
design air flow.
❑Not Observable
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies Requirement will be met.
[FI9]2 installed for control of primary ❑Does Not
heating and cooling systems and
initially set by manufacturer to Not Observable
code specifications. ❑Not Applicable
403.1.2 Heat pump thermostat installed ElComplies Exception: Requirement is
[Fi10]2 on heat pumps. ElDoes Not not applicable.
❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Bardin Project Report date: 06/06/18
Data filename: C:\FJ\Arch Design\Bardin\Bardin Project.rck Page 7 of 9
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
&Req.ID
403.5.1 Circulating service hot water ❑Complies Requirement will be met.
[FI11]2 systems have automatic or ❑Does Not
accessible manual controls.
['Not Observable
❑Not Applicable
403.6.1 All mechanical ventilation system! ❑Complies Requirement will be met.
[F125]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air flow limits. Not Observable
❑Not Applicable
403.2 Hot water boilers supplying heat ❑Complies Exception: Requirement is
[FI26]2 through one-or two-pipe heating ❑Does Not not applicable.
systems have outdoor setback
control to lower boiler water ❑Not Observable
temperature based on outdoor ❑Not Applicable
temperature.
403.5.1.1 Heated water circulation systems ❑Complies Requirement will be met.
[FI28]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply ['Not Observable
pipe. Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy.Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems ❑Complies Exception: Requirement is
[FI29)2 comply with IEEE 515.1 or UL '❑Does Not not applicable.
515.Controls automatically
adjust the energy input to the ❑Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that ❑Complies Requirement will be met.
[F130]2 have recirculation pumps that ElDoes Not
pump water from a heated water
supply pipe back to the heated Not Observable
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 104°F.
403.5.4 Drain water heat recovery units ❑Complies Requirement will be met.
[F13112 tested in accordance with CSA ['Does Not
B55.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units< 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units< 2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies Requirement will be met.
[F16]1 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps.
Does not apply to low-voltage ['Not Observable
lighting. ❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Bardin Project Report date: 06/06/18
Data filename: C:\Fj\Arch Design\Bardin\Bardin Project.rck Page 8 of 9
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.lD
404.1.1 Fuel gas lighting systems have ❑Complies Requirement will be met.
[FI23]3 no continuous pilot light. ❑Does Not
❑Not Observable
❑Not Applicable
401.3 Compliance certificate posted. ❑Complies Requirement will be met.
[Fl7]2 ❑Does Not
❑Not Observable
❑Not Applicable
303.3 Manufacturer manuals for ❑Complies Requirement will be met.
[FI18]3 mechanical and water heating ❑Does Not
systems have been provided.
['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Bardin Project Report date: 06/06/18
Data filename: C:\FJ\Arch Design\Bardin\Bardin Project.rck Page 9 of 9
a
i20 IE
CI Efficie15ncyCC Energy Certificate
Insulation Rating R-Value
Above-Grade Wall 21.00
Below-Grade Wall 21.00
Floor 30.00
Ceiling/ Roof 49.00
Ductwork(unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.26
Door 0.26
Heating&Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments