inspection 03252019INSPECTION WORKSHEET (001593-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-000719-2017 Case Module:Permit
Inspection Date:Mon Mar 25, 2019 Inspection Status:Partial Pass
Inspector:Charles Dyer Inspection Type:Residential Final Inspection
Job Address:Parcel Number:40 Sunnyside E
Queensbury, NY 12804
290.6-1-62.2
Contact Type Company Name Name
Applicant Callahan, Paul
Primary Owner Callahan, Paul
Granted Permission Callahan, Paul
Architect Northern Design & Building Associates
Checklist Item Passed Comments
General Comments NO 3/13/19~ walk through for conditions of temporary C/O
1. Complete siding
2.Complete basement for insulation @ cavities of studs for
prescriptive method
3. Blower door test must be less than 3 (ach) air changes per
hour
4. Winter conditions- grade to be within 6/10
4 inch Building Number Address visible from road YES
Chimney Height / B Vent / Direct Vent Location YES
Fresh Air Intake YES
Fresh air supply 3' from grade YES
Mar 25, 2019 Page (1)
INSPECTION WORKSHEET (001593-2019)
Checklist Item Passed Comments
3" Plumbing Vent through roof minimum 18 inch YES
Outside Spigots have Air Gap YES
Roof Complete / Exterior Finish Complete NO Complete siding
Platform at all exterior doors YES
Handrail 4 or more risers YES Provide handrail @ front steps
Verified 3/25/18
Guards at stairs,decks,patios 30" + above grade YES
Guard at stairwell at 34" or more YES
Window guards req:<2' above floor/6' above
grade - quick release installed
YES
Guard at deck, porches 36" or more YES
Handrail Termination at Newell Post or Wall YES Call when ready
Verified stairs for guard and handrail 3/25/19
Interior/Exterior Railings 34 to 38 YES
4+ Deck Joist Ledger Connections-24" From
Ends
YES
Deck Ledger-Bolted per Code YES
Grade away from foundation: 6" down, 10' out NO Winter conditions
Mar 25, 2019 Page (2)
INSPECTION WORKSHEET (001593-2019)
Checklist Item Passed Comments
6" clearance to sill plate YES
Gas Shut-off Exposed & Regulator (18) Above
Grade
NO Propane
HVAC Vent Terminal 10' from Lot Line &
Openings
YES
Interior privacy/trim/doors/main entrance 36 YES
Bathroom / Kitchen Watertight YES
Low flow toilet 1.3 gal/flushing cycle -
showerhead/faucet
YES
Smoke Detectors: Carbon Monoxide YES
Smoke Detectors 3' from Kitchens & Baths R314 YES
Every level, Every bedroom YES
Outside every bedroom area YES
Inter Connected YES
Battery backup: _____YES
Attic Access 22 x 30 minimum YES Provide weather stripping at trim of access
Attic Access Insulation = Attic R- Value YES
Attic Access Gasketed NO
Mar 25, 2019 Page (3)
INSPECTION WORKSHEET (001593-2019)
Checklist Item Passed Comments
Bathroom Fans, if no window YES
Plumbing fixtures YES
Backflow Preventors where required YES
Foundation insulation to floor NO
Energy Sticker on Elec. Panel:R-Val. & Heating
Sys
NO
All Hot Water Systems: R-3 YES
Duct work sealed properly YES
Intake Openings YES
Blower Door Test Certification NO
HRV or ERV Installed per Bedroom Requirements YES
Emergency egress below grade YES
Furnace shut-off w/in 30 ft. or w/in line of site YES
Propane Tank: Proper Setback from Prop
Line/Struct
YES
Furnace Hot Water Heater operating YES
Relief Valve ,Heat Trap/Water Temp 110 deg or
less
YES
Mar 25, 2019 Page (4)
INSPECTION WORKSHEET (001593-2019)
Checklist Item Passed Comments
1/2" Gypsum or House Wall and Gable YES
20 Minute Fire Door/Self-Closing Hardware YES
Seals on Garage Doors, esp. Wood YES
Basement stairs closed rise greater than 4 inches YES
Basement Egress: 5s.f. window w/sill or Bilco
door
YES Door
Garage Floor Pitched YES
Gas Log In Sealed or Glass Enclosure YES
Fin Elect; Energy Saving Light Bulbs 50 Percent YES
Final Survey Plot Plan NO Provide final survey
Arc Fault Breaker Habitable Spaces YES
As Built Septic System NO Provide septic asbuilt
Buried Fuel Tanks anchored in flood zone NO
Truss ID Signage Installed at Electrical Meter NO Provide truss ID visible from driveway
OK to Issue Temporary C/O YES Ok to issue temp CO for conditions listed at note # 1 top of
page
OK to Issue C/O NO
Mar 25, 2019 Page (5)
Dyer, Charles (Inspector)