Loading...
inspection 03252019INSPECTION WORKSHEET (001593-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-000719-2017 Case Module:Permit Inspection Date:Mon Mar 25, 2019 Inspection Status:Partial Pass Inspector:Charles Dyer Inspection Type:Residential Final Inspection Job Address:Parcel Number:40 Sunnyside E Queensbury, NY 12804 290.6-1-62.2 Contact Type Company Name Name Applicant Callahan, Paul Primary Owner Callahan, Paul Granted Permission Callahan, Paul Architect Northern Design & Building Associates Checklist Item Passed Comments General Comments NO 3/13/19~ walk through for conditions of temporary C/O 1. Complete siding 2.Complete basement for insulation @ cavities of studs for prescriptive method 3. Blower door test must be less than 3 (ach) air changes per hour 4. Winter conditions- grade to be within 6/10 4 inch Building Number Address visible from road YES Chimney Height / B Vent / Direct Vent Location YES Fresh Air Intake YES Fresh air supply 3' from grade YES Mar 25, 2019 Page (1) INSPECTION WORKSHEET (001593-2019) Checklist Item Passed Comments 3" Plumbing Vent through roof minimum 18 inch YES Outside Spigots have Air Gap YES Roof Complete / Exterior Finish Complete NO Complete siding Platform at all exterior doors YES Handrail 4 or more risers YES Provide handrail @ front steps Verified 3/25/18 Guards at stairs,decks,patios 30" + above grade YES Guard at stairwell at 34" or more YES Window guards req:<2' above floor/6' above grade - quick release installed YES Guard at deck, porches 36" or more YES Handrail Termination at Newell Post or Wall YES Call when ready Verified stairs for guard and handrail 3/25/19 Interior/Exterior Railings 34 to 38 YES 4+ Deck Joist Ledger Connections-24" From Ends YES Deck Ledger-Bolted per Code YES Grade away from foundation: 6" down, 10' out NO Winter conditions Mar 25, 2019 Page (2) INSPECTION WORKSHEET (001593-2019) Checklist Item Passed Comments 6" clearance to sill plate YES Gas Shut-off Exposed & Regulator (18) Above Grade NO Propane HVAC Vent Terminal 10' from Lot Line & Openings YES Interior privacy/trim/doors/main entrance 36 YES Bathroom / Kitchen Watertight YES Low flow toilet 1.3 gal/flushing cycle - showerhead/faucet YES Smoke Detectors: Carbon Monoxide YES Smoke Detectors 3' from Kitchens & Baths R314 YES Every level, Every bedroom YES Outside every bedroom area YES Inter Connected YES Battery backup: _____YES Attic Access 22 x 30 minimum YES Provide weather stripping at trim of access Attic Access Insulation = Attic R- Value YES Attic Access Gasketed NO Mar 25, 2019 Page (3) INSPECTION WORKSHEET (001593-2019) Checklist Item Passed Comments Bathroom Fans, if no window YES Plumbing fixtures YES Backflow Preventors where required YES Foundation insulation to floor NO Energy Sticker on Elec. Panel:R-Val. & Heating Sys NO All Hot Water Systems: R-3 YES Duct work sealed properly YES Intake Openings YES Blower Door Test Certification NO HRV or ERV Installed per Bedroom Requirements YES Emergency egress below grade YES Furnace shut-off w/in 30 ft. or w/in line of site YES Propane Tank: Proper Setback from Prop Line/Struct YES Furnace Hot Water Heater operating YES Relief Valve ,Heat Trap/Water Temp 110 deg or less YES Mar 25, 2019 Page (4) INSPECTION WORKSHEET (001593-2019) Checklist Item Passed Comments 1/2" Gypsum or House Wall and Gable YES 20 Minute Fire Door/Self-Closing Hardware YES Seals on Garage Doors, esp. Wood YES Basement stairs closed rise greater than 4 inches YES Basement Egress: 5s.f. window w/sill or Bilco door YES Door Garage Floor Pitched YES Gas Log In Sealed or Glass Enclosure YES Fin Elect; Energy Saving Light Bulbs 50 Percent YES Final Survey Plot Plan NO Provide final survey Arc Fault Breaker Habitable Spaces YES As Built Septic System NO Provide septic asbuilt Buried Fuel Tanks anchored in flood zone NO Truss ID Signage Installed at Electrical Meter NO Provide truss ID visible from driveway OK to Issue Temporary C/O YES Ok to issue temp CO for conditions listed at note # 1 top of page OK to Issue C/O NO Mar 25, 2019 Page (5) Dyer, Charles (Inspector)