inspection 08272018INSPECTION WORKSHEET (SEP-006182-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:
Inspection Date:
Inspector:
Case Module:
Inspection Status:
Inspection Type:
RC-000719-2017
08/27/2018
John O'Brien
Permit
Partial Pass
Septic
Job Address:Parcel Number:40 Sunnyside E
Queensbury, NY 12804
290.6-1-62.2
Contact Type Company Name Name
Architect Northern Design & Building Associates ,
Applicant Callahan, Paul
Granted Permission Callahan, Paul
Primary Owner Callahan, Paul
Checklist Item Passed Comments
Building Inspector Notes NO 8/27/18 Septic System Partial Approval
-Provide Engineer's As-Built and Final Approval
Soil Type: Loam YES
Soil Type: Clay YES
Type of Water: Municipal / Well Water YES Well
Waterline separation distance YES
Well separation distance YES
Well Casing Lengt: 50ft +/-YES
Absorbtion Fields: Total Length YES 300 ft
Length of Each Trench YES 6@50 ft
Depth of Trenches YES 24-30 inches
Size of Stone YES #2
Building to Tank YES 4 inch sch40
Tank to Distribution Box YES 4 inch sdr35 pvc
Distribution box to Field / Pit YES 4 inch pvc to 4 inch pvc perforated
Opening Sealed:YES
End Cap YES
InletOutlet Pipes & Baffles YES
Manholes 12 or less below grade YES
Locations / Separations YES
Foundation to Tank YES 10 ft +
Foundation to Absorption YES 21 ft
Engineer Report and As-Built YES 8/27/18 Septic System Partial Approval
-Provide Engineer's As-Built and Final Approval
Location of system on property YES Rear left side
System Use Status YES 8/27/18 Septic System Partial Approval
Aug 27, 2018 Page (1)
INSPECTION WORKSHEET (SEP-006182-2018)
Checklist Item Passed Comments
-Provide Engineer's As-Built and Final Approval
Aug 27, 2018 Page (2)
O'Brien, John (Inspector)