inspection 03132019INSPECTION WORKSHEET (001394-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-000719-2017Case Module:Permit Inspection Date:Wed Mar 13, 2019Inspection Status:Partial Pass Inspector:Charles DyerInspection Type:Residential Final Inspection Job Address:40 Sunnyside EParcel Number:290.6-1-62.2 Queensbury, NY 12804 Contact TypeCompany NameName ApplicantCallahan, Paul Granted PermissionCallahan, Paul ArchitectNorthern Design & Building Associates Primary OwnerCallahan, Paul Checklist ItemPassedComments General CommentsNO3/13/19~ walk through for conditions of temporary C/O 1. Complete siding 2.Complete basement for insulation @ cavities of studs for prescriptive method 3. Blower door test must be less than 3 (ach) air changes per hour 4. Winter conditions- grade to be within 6/10 4 inch Building Number Address visible from roadYES Chimney Height / B Vent / Direct Vent LocationYES Fresh Air IntakeNO Fresh air supply 3' from gradeYES Mar 13, 2019Page (1) INSPECTION WORKSHEET (001394-2019) Checklist ItemPassedComments 3" Plumbing Vent through roof minimum 18 inchYES Outside Spigots have Air GapNO Roof Complete / Exterior Finish CompleteNO Platform at all exterior doorsYES Handrail 4 or more risersNOProvide handrail @ front steps Guards at stairs,decks,patios 30" + above gradeNO Guard at stairwell at 34" or moreNO Window guards req:<2' above floor/6' aboveYES grade - quick release installed Guard at deck, porches 36" or moreNO Handrail Termination at Newell Post or WallNOCall when ready Interior/Exterior Railings 34 to 38NO Wood deck: 2'+ from grade dia bracing required -NO H/C ramp compliant 4+ Deck Joist Ledger Connections-24" FromNO Ends Deck Ledger-Bolted per CodeNO Grade away from foundation 6 with 10 feetNOWinter conditions Mar 13, 2019Page (2) INSPECTION WORKSHEET (001394-2019) Checklist ItemPassedComments 6 clearance to sill plateYES Gas Shut-off Exposed & Regulator (18) AboveNO Grade HVAC Vent Terminal 10' from Lot Line &YES Openings Interior privacy/trim/doors/main entrance 36NO Bathroom / Kitchen WatertightYES Low flow toilet 1.3 gal/flushing cycle -YES showerhead/faucet Smoke Detectors: Carbon MonoxideYES Smoke Detectors 3' from Kitchens & Baths R314YES Every level, Every bedroomYES Outside every bedroom areaYES Inter ConnectedYES Battery backup: _____YES Attic Access 22 x 30 minimumYESProvide weather stripping at trim of access Attic Access Insulation = Attic R- ValueYES Attic Access GasketedNO Mar 13, 2019Page (3) INSPECTION WORKSHEET (001394-2019) Checklist ItemPassedComments Crawl Space Access 18 x 24NO Bathroom Fans, if no windowYES Plumbing fixturesYES Backflow Preventors where requiredYES Foundation insulation to floorNO Energy Sticker on Elec. Panel:R-Val. & HeatingNO Sys All Hot Water Systems: R-3NO Duct work sealed properlyYES Intake OpeningsYES Blower Door Test CertificationNO HRV or ERV Installed per Bedroom RequirementsYES Emergency egress below gradeYES Furnace shut-off w/in 30 ft. or w/in line of siteYES Propane Tank: Proper Setback from PropYES Line/Struct Furnace Hot Water Heater operatingYES Mar 13, 2019Page (4) INSPECTION WORKSHEET (001394-2019) Checklist ItemPassedComments Relief Valve ,Heat Trap/Water Temp 110 deg orNO less 1/2" Gypsum or House Wall and GableYES 20 Minute Fire Door/Self-Closing HardwareYES Seals on Garage Doors, esp. WoodYES Basement stairs closed rise greater than 4 inchesNO Basement Egress: 5s.f. window w/sill or BilcoYESDoor door Garage Floor PitchedYES Gas Log In Sealed or Glass EnclosureYES Fin Elect; Energy Saving Light Bulbs 50 PercentYES Final Survey Plot PlanNO Arc Fault Breaker Habitable SpacesNO Flex Gas Pipe BondingNO As Built Septic SystemNO Sewer Dept. Inspection StickerNO Flood Plain Certification, if requiredNO Mar 13, 2019Page (5) INSPECTION WORKSHEET (001394-2019) Checklist ItemPassedComments Fuel Tanks above flood plain elevationNO Buried Fuel Tanks anchored in flood zoneNO Truss ID Signage Installed at Electrical MeterNO OK to Issue Temporary C/ONO OK to Issue C/ONO Dyer, Charles (Inspector) Mar 13, 2019Page (6)