inspection 03132019INSPECTION WORKSHEET (001394-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-000719-2017Case Module:Permit
Inspection Date:Wed Mar 13, 2019Inspection Status:Partial Pass
Inspector:Charles DyerInspection Type:Residential Final Inspection
Job Address:40 Sunnyside EParcel Number:290.6-1-62.2
Queensbury, NY 12804
Contact TypeCompany NameName
ApplicantCallahan, Paul
Granted PermissionCallahan, Paul
ArchitectNorthern Design & Building Associates
Primary OwnerCallahan, Paul
Checklist ItemPassedComments
General CommentsNO3/13/19~ walk through for conditions of temporary C/O
1. Complete siding
2.Complete basement for insulation @ cavities of studs for
prescriptive method
3. Blower door test must be less than 3 (ach) air changes per
hour
4. Winter conditions- grade to be within 6/10
4 inch Building Number Address visible from roadYES
Chimney Height / B Vent / Direct Vent LocationYES
Fresh Air IntakeNO
Fresh air supply 3' from gradeYES
Mar 13, 2019Page (1)
INSPECTION WORKSHEET (001394-2019)
Checklist ItemPassedComments
3" Plumbing Vent through roof minimum 18 inchYES
Outside Spigots have Air GapNO
Roof Complete / Exterior Finish CompleteNO
Platform at all exterior doorsYES
Handrail 4 or more risersNOProvide handrail @ front steps
Guards at stairs,decks,patios 30" + above gradeNO
Guard at stairwell at 34" or moreNO
Window guards req:<2' above floor/6' aboveYES
grade - quick release installed
Guard at deck, porches 36" or moreNO
Handrail Termination at Newell Post or WallNOCall when ready
Interior/Exterior Railings 34 to 38NO
Wood deck: 2'+ from grade dia bracing required -NO
H/C ramp compliant
4+ Deck Joist Ledger Connections-24" FromNO
Ends
Deck Ledger-Bolted per CodeNO
Grade away from foundation 6 with 10 feetNOWinter conditions
Mar 13, 2019Page (2)
INSPECTION WORKSHEET (001394-2019)
Checklist ItemPassedComments
6 clearance to sill plateYES
Gas Shut-off Exposed & Regulator (18) AboveNO
Grade
HVAC Vent Terminal 10' from Lot Line &YES
Openings
Interior privacy/trim/doors/main entrance 36NO
Bathroom / Kitchen WatertightYES
Low flow toilet 1.3 gal/flushing cycle -YES
showerhead/faucet
Smoke Detectors: Carbon MonoxideYES
Smoke Detectors 3' from Kitchens & Baths R314YES
Every level, Every bedroomYES
Outside every bedroom areaYES
Inter ConnectedYES
Battery backup: _____YES
Attic Access 22 x 30 minimumYESProvide weather stripping at trim of access
Attic Access Insulation = Attic R- ValueYES
Attic Access GasketedNO
Mar 13, 2019Page (3)
INSPECTION WORKSHEET (001394-2019)
Checklist ItemPassedComments
Crawl Space Access 18 x 24NO
Bathroom Fans, if no windowYES
Plumbing fixturesYES
Backflow Preventors where requiredYES
Foundation insulation to floorNO
Energy Sticker on Elec. Panel:R-Val. & HeatingNO
Sys
All Hot Water Systems: R-3NO
Duct work sealed properlyYES
Intake OpeningsYES
Blower Door Test CertificationNO
HRV or ERV Installed per Bedroom RequirementsYES
Emergency egress below gradeYES
Furnace shut-off w/in 30 ft. or w/in line of siteYES
Propane Tank: Proper Setback from PropYES
Line/Struct
Furnace Hot Water Heater operatingYES
Mar 13, 2019Page (4)
INSPECTION WORKSHEET (001394-2019)
Checklist ItemPassedComments
Relief Valve ,Heat Trap/Water Temp 110 deg orNO
less
1/2" Gypsum or House Wall and GableYES
20 Minute Fire Door/Self-Closing HardwareYES
Seals on Garage Doors, esp. WoodYES
Basement stairs closed rise greater than 4 inchesNO
Basement Egress: 5s.f. window w/sill or BilcoYESDoor
door
Garage Floor PitchedYES
Gas Log In Sealed or Glass EnclosureYES
Fin Elect; Energy Saving Light Bulbs 50 PercentYES
Final Survey Plot PlanNO
Arc Fault Breaker Habitable SpacesNO
Flex Gas Pipe BondingNO
As Built Septic SystemNO
Sewer Dept. Inspection StickerNO
Flood Plain Certification, if requiredNO
Mar 13, 2019Page (5)
INSPECTION WORKSHEET (001394-2019)
Checklist ItemPassedComments
Fuel Tanks above flood plain elevationNO
Buried Fuel Tanks anchored in flood zoneNO
Truss ID Signage Installed at Electrical MeterNO
OK to Issue Temporary C/ONO
OK to Issue C/ONO
Dyer, Charles (Inspector)
Mar 13, 2019Page (6)