inspection 01162018INSPECTION WORKSHEET (BINS-000307-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:Case Module:
RC-000719-2017Permit
Inspection Date:Inspection Status:
01/16/2018Partial Pass
Inspector:Inspection Type:
Charles DyerBuilding Foundation
Job Address:Parcel Number:
40 Sunnyside E290.6-1-62.2
Queensbury, NY 12804
Contact TypeCompany NameName
ArchitectNorthern Design & Building Associates,
Primary OwnerCallahan, Paul
Granted PermissionCallahan, Paul
ApplicantCallahan, Paul
Checklist ItemPassedComments
Building Inspector NotesNO1/10/18 Foundation Waterproofing, Foamboard , Foundation drainage,
and Backfill Approved
FootingsYESApproved 12/15/17
For garage 1/16/18 Approved
PiersNO
Monolithic SlabNO
Foundation / WallpourYESFor frost wall only- approved 12/18/17
Approved 12/20/17
Reinforcement in PlaceNO
Reinforcement in PlaceYES2 #4s continuous
Wall- 3 rows # 4
Footing Dowels or Keyway in placeYESWet sticking
Pins 36? oc
Foundation WaterproofingYES
Footing Drain Daylight or SumpYES
Footing Drain Stone - 12 inch widthYES
Footing Drain Stone - 6 inches above footingYES
Footing Drain stone - 6 mil polyYESFabric
Backfill ApprovalYES
Plumbing Under SlabNO
PVC / Cast / CopperNO
Foundation Insulation Interior / ExteriorNO
Rough Grade 6 inch drop within 10 ft.NO
Poly Under SlabYES
Dyer, Charles (Inspector)
Jan 16, 2018Page (1)