Loading...
ResCheck t ,� r=„ REScheck Software Version 4.6.5 Compliancele Certificate :„, Project The Williams Residence O F �Ey,y RSA 0 Energy Code: 2015 IECC F� 1) Location: Glens Falls, New York 1 t0 Construction Type: Single-family Project Type: New Construction w Orientation: Unspecified �iy .� a Conditioned Floor Area: 240 ft2 `���� G$ Glazing Area 13% trito v Climate Zone: 6 (7635 HDD) Permit Date: 17 August, 2018 Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 27 Carlton Drive Queensbury, NY 12804 REVIEWED FOR Compliance: Passes using UA trade-off Compliance: 4.7%Better Than Code Maximum UA: 43 Your UA: 41 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Walls:Wood Frame, 16" o.c. 352 21.0 5.0 0.043 13 Orientation: Unspecified 36"x60" Window:Vinyl/Fiberglass Frame:Double Pane with Low-E 15 0.300 5 Orientation: Unspecified 36"x60"(2)Window: Vinyl/Fiberglass Frame:Double Pane with Low-E 30 0.300 9 Orientation: Unspecified Ceiling 1: Flat Ceiling or Scissor Truss 240 49.0 0.0 0.026 6 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 240 30.0 0.0 0.033 8 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been de igned to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements lis in th EScheck Inspection Checklist. 47. 'Ike 1)' F11#47Z 7— /7::-..' ' / AY3Ar Name-Title Signatur -' Date A C C D I EB FILE COPY a OCT 11 2018 TOWN OF QUEENSSBB S Y Proje TRIP Report date: 10/01/18 Data filename: C:\Users\jeb\Documents\Williams.rck Page 1 of 9 REScheck Software Version 4.6.5 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate [1]Does Not [PR1]1 energy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.71 energy code compliance for ❑Not Observable [PR3] lighting and mechanical systems. Systems serving multiple Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods Btu/hr Btu/hr ❑Not Observable approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Williams Residence Report date: 10/01/18 Data filename: C:\Users\jeb\Documents\Williams.rck Page 2 of 9 Section Foundation Inspection Complies? Comments/Assumptions & Req.ID 303.2.1 A protective covering is installed to ❑Complies [FO11]2 protect exposed exterior insulation ❑Does Not and extends a minimum of 6 in. below grade. ❑Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system controls ❑Complies [FO12]2 installed. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1�High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 I Low Impact(Tier 3) Project Title: The Williams Residence Report date: 10/01/18 Data filename: C:\Users\jeb\Documents\Williams.rck Page 3 of 9 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, • 402.5 ❑Not Observable [FR2]1 ❑Not Applicable 303.1.3 U-factors of fenestration products i ❑Complies [FR4]1 are determined in accordance ;- ❑Does Not with the NFRC test procedure or 3 ❑Not Observable taken from the default table. ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier f ❑Com lies p [FR23]1 installed per manufacturer's f; [` . ❑Does Not instructions. r ;.;,❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting i f ❑Does Not AAMA/WDMA/CSA 101/1.5.2/A440 1 ' 'k`i El Not Observable or has infiltration rates per NFRC 400 that do not exceed code Not Applicable limits. •402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate <_2.0 cfm leakage at 75 Pa. ['Not Observable fi'" ❑Not Applicable 403.3.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >= R-6 where < 3 inches.Supply and ❑Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.5 Building cavities are not used as LiComplies [FR15]3 ducts or plenums. ElDoes Not a ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105°F or chilled fluids ❑Does Not below 55°F are insulated to >_R- 3 ❑Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC # � ❑Complies [FR24]1 piping. 3 ❑Does Not ❑Not Observable • • ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air 3 ❑Does Not intakes and exhausts. 3 ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1[High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Williams Residence Report date: 10/01/18 Data filename: C:\Users\jeb\Documents\Williams.rck Page 4 of 9 • • Section Plans Verified Field Verified Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 ❑ Steel Steel ❑Not Observable ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the t; underside of the subfloor, or floor ❑Not Observable framing cavity insulation is in ❑Not Applicable contact with the top side of ' ;4 sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- R- '❑Complies 'See the Envelope Assemblies 402.2.5, mass wall with at least V2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall [IN3]1 exterior,the exterior insulation Mass Mass❑ ❑Not Observable requirement applies(FR10). [II Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per � ,.❑Complies [IN4]1 manufacturer's instructions. ❑ Does Not 3F r ❑Not Observable , ,k �; ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Williams Residence Report date: 10/01/18 Data filename: C:\Users\jeb\Documents\Williams.rck Page 6 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel 402.2.E ❑Not Observable [FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [F12]1 Blown insulation marked every 300 ft2. ❑Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [F122]2 insulation include baffle adjacent € = =❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ' „❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]1 insulation >_R-value of the •❑Does Not •adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [F117]1 'ach in Climate Zones 1-2, and ❑Does Not •<=3 ach in Climate Zones 3-8. •❑Not Observable ❑Not Applicable 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F14]1 cfm/100 ft2 across the system or ft2 ft2 .❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ❑Not Observable tests,•verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 :❑Complies [FI27]1 determine air leakage with ft2 ft2 •❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch • w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated i .-- ❑Complies [FI24]1 by manufacturer at<=2%of getgroi-gpartuittritemiRmtp.-giz.,15,1:,:,;,:egiag.,:e..-soi!L_IDoes Not design air flow. ❑Not Observable El Not Applicable 403.1.1 Programmable thermostats x � ' ❑Complies [F19]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to _ ❑Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [F110]2 on heat pumps. _ `,-❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water k ❑Complies [FI11]2 systems have automatic or El Does Not accessible manual controls. } ;.- ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: The Williams Residence Report date: 10/01/18 Data filename: C:\Users\jeb\Documents\Williams.rck Page 7 of 9 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system ❑Complies [F125]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy • and air flow limits. ['Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F128]2 have a circulation pump.The Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable p p pp y ❑Not Applicable pipe. Gravity and thermos- circulation systems aretenginaintat'aga:;4::::V00:402•214nRigii:517.0 not present. Controls for circulating hot water system pumps start the pump with signal x for hot water demand within the 1 - _ x, ", occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems i,,,,,,� =` ❑Complies [FI29]2 comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [FI30]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold ElNot Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units J ❑Complies [FI31]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [F16]1 fixtures or 75%of permanent ElDoes Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ': ❑Complies [F123]3 no continuous pilot light. ❑Does Not Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Williams Residence Report date: 10/01/18 Data filename: C:\Users\jeb\Documents\Williams.rck Page 8 of 9 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 401.3 Compliance certificate posted. UComplies [Fl7]2 LiDoes Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for • LJComplies [F118]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Williams Residence Report date: 10/01/18 Data filename: C:\Users\jeb\Documents\Williams.rck Page 9 of 9 he 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 26.00 Below-Grade Wall 0.00 Floor 30.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.30 Door Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments