,� r=„ REScheck Software Version 4.6.5
Compliancele
Certificate
:„,
Project The Williams Residence O
F �Ey,y
RSA 0
Energy Code: 2015 IECC F� 1)
Location: Glens Falls, New York 1 t0
Construction Type: Single-family
Project Type: New Construction w
Orientation: Unspecified �iy .� a
Conditioned Floor Area: 240 ft2 `���� G$
Glazing Area 13% trito v
Climate Zone: 6 (7635 HDD)
Permit Date: 17 August, 2018
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
27 Carlton Drive
Queensbury, NY 12804
REVIEWED FOR
Compliance: Passes using UA trade-off
Compliance: 4.7%Better Than Code Maximum UA: 43 Your UA: 41
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Walls:Wood Frame, 16" o.c. 352 21.0 5.0 0.043 13
Orientation: Unspecified
36"x60" Window:Vinyl/Fiberglass Frame:Double Pane with Low-E 15 0.300 5
Orientation: Unspecified
36"x60"(2)Window: Vinyl/Fiberglass Frame:Double Pane with Low-E 30 0.300 9
Orientation: Unspecified
Ceiling 1: Flat Ceiling or Scissor Truss 240 49.0 0.0 0.026 6
Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 240 30.0 0.0 0.033 8
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application.The proposed building has been de igned to meet the 2015 IECC requirements in
REScheck Version 4.6.5 and to comply with the mandatory requirements lis in th EScheck Inspection Checklist.
47. 'Ike 1)' F11#47Z 7—
/7::-..' ' / AY3Ar
Name-Title Signatur -' Date
A C C D I EB FILE COPY
a OCT 11 2018
TOWN OF QUEENSSBB S Y
Proje TRIP Report date: 10/01/18
Data filename: C:\Users\jeb\Documents\Williams.rck Page 1 of 9
REScheck Software Version 4.6.5
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate [1]Does Not
[PR1]1 energy code compliance for the
building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.71 energy code compliance for ❑Not Observable
[PR3] lighting and mechanical systems.
Systems serving multiple Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling:
Manual J or other methods Btu/hr Btu/hr ❑Not Observable
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: The Williams Residence Report date: 10/01/18
Data filename: C:\Users\jeb\Documents\Williams.rck Page 2 of 9
Section
Foundation Inspection Complies? Comments/Assumptions
& Req.ID
303.2.1 A protective covering is installed to ❑Complies
[FO11]2 protect exposed exterior insulation ❑Does Not
and extends a minimum of 6 in. below
grade. ❑Not Observable
❑Not Applicable
403.9 Snow-and ice-melting system controls ❑Complies
[FO12]2 installed. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1�High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 I Low Impact(Tier 3)
Project Title: The Williams Residence Report date: 10/01/18
Data filename: C:\Users\jeb\Documents\Williams.rck Page 3 of 9
Section Plans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
• 402.5 ❑Not Observable
[FR2]1 ❑Not Applicable
303.1.3 U-factors of fenestration products i ❑Complies
[FR4]1 are determined in accordance ;- ❑Does Not
with the NFRC test procedure or 3
❑Not Observable
taken from the default table. ❑Not Applicable
402.4.1.1 Air barrier and thermal barrier f ❑Com lies
p
[FR23]1 installed per manufacturer's f; [` . ❑Does Not
instructions.
r ;.;,❑Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting i f ❑Does Not
AAMA/WDMA/CSA 101/1.5.2/A440 1 ' 'k`i El Not Observable
or has infiltration rates per NFRC
400 that do not exceed code Not Applicable
limits.
•402.4.5 IC-rated recessed lighting fixtures ❑Complies
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate <_2.0 cfm
leakage at 75 Pa. ['Not Observable
fi'" ❑Not Applicable
403.3.1 Supply and return ducts in attics ❑Complies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >=
R-6 where < 3 inches.Supply and ❑Not Observable
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.5 Building cavities are not used as LiComplies
[FR15]3 ducts or plenums. ElDoes Not
a ❑Not Observable
❑Not Applicable
403.4 HVAC piping conveying fluids R- R- ❑Complies
[FR17]2 above 105°F or chilled fluids ❑Does Not
below 55°F are insulated to >_R-
3 ❑Not Observable
❑Not Applicable
403.4.1 Protection of insulation on HVAC # � ❑Complies
[FR24]1 piping. 3 ❑Does Not
❑Not Observable
•
• ❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- ❑Complies
[FR18]2 >_R-3. ❑Does Not
❑Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are ❑Complies
[FR19]2 installed on all outdoor air 3 ❑Does Not
intakes and exhausts. 3
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1[High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: The Williams Residence Report date: 10/01/18
Data filename: C:\Users\jeb\Documents\Williams.rck Page 4 of 9
•
•
Section Plans Verified Field Verified
Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
303.1 All installed insulation is labeled ❑Complies
[IN13]2 or the installed R-values ❑Does Not
provided.
❑Not Observable
❑Not Applicable
402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values.
[IN1]1 ❑ Steel Steel ❑Not Observable
❑Not Applicable
303.2, Floor insulation installed per ❑Complies
402.2.7 manufacturer's instructions and ❑Does Not
[IN2]1 in substantial contact with the t;
underside of the subfloor, or floor ❑Not Observable
framing cavity insulation is in ❑Not Applicable
contact with the top side of ' ;4
sheathing, or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
402.1.1, Wall insulation R-value. If this is a R- R- '❑Complies 'See the Envelope Assemblies
402.2.5, mass wall with at least V2 of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall
[IN3]1 exterior,the exterior insulation Mass Mass❑ ❑Not Observable
requirement applies(FR10). [II Steel ❑ Steel ❑Not Applicable
303.2 Wall insulation is installed per � ,.❑Complies
[IN4]1 manufacturer's instructions. ❑
Does Not
3F r ❑Not Observable
, ,k �; ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: The Williams Residence Report date: 10/01/18
Data filename: C:\Users\jeb\Documents\Williams.rck Page 6 of 9
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2, ❑ Steel ❑ Steel
402.2.E ❑Not Observable
[FI1]1 ❑Not Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[F12]1 Blown insulation marked every
300 ft2. ❑Not Observable
❑Not Applicable
402.2.3 Vented attics with air permeable ❑Complies
[F122]2 insulation include baffle adjacent € = =❑Does Not
to soffit and eave vents that
extends over insulation. ❑Not Observable
' „❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies
[F13]1 insulation >_R-value of the •❑Does Not
•adjacent assembly.
❑Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies
[F117]1 'ach in Climate Zones 1-2, and ❑Does Not
•<=3 ach in Climate Zones 3-8. •❑Not Observable
❑Not Applicable
403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
[F14]1 cfm/100 ft2 across the system or ft2 ft2 .❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ❑Not Observable
tests,•verification may need to ❑Not Applicable
occur during Framing Inspection.
403.3.3 Ducts are pressure tested to cfm/100 cfm/100 :❑Complies
[FI27]1 determine air leakage with ft2 ft2 •❑Does Not
either: Rough-in test:Total
leakage measured with a ❑Not Observable
pressure differential of 0.1 inch ❑Not Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch •
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated i .-- ❑Complies
[FI24]1 by manufacturer at<=2%of getgroi-gpartuittritemiRmtp.-giz.,15,1:,:,;,:egiag.,:e..-soi!L_IDoes Not
design air flow.
❑Not Observable
El Not Applicable
403.1.1 Programmable thermostats
x � ' ❑Complies
[F19]2 installed for control of primary ❑Does Not
heating and cooling systems and
initially set by manufacturer to _ ❑Not Observable
code specifications. ❑Not Applicable
403.1.2 Heat pump thermostat installed ❑Complies
[F110]2 on heat pumps. _ `,-❑Does Not
❑Not Observable
❑Not Applicable
403.5.1 Circulating service hot water k ❑Complies
[FI11]2 systems have automatic or El Does Not
accessible manual controls. }
;.- ❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3)
Project Title: The Williams Residence Report date: 10/01/18
Data filename: C:\Users\jeb\Documents\Williams.rck Page 7 of 9
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.6.1 All mechanical ventilation system ❑Complies
[F125]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
• and air flow limits. ['Not Observable
❑Not Applicable
403.2 Hot water boilers supplying heat ❑Complies
[F126]2 through one-or two-pipe heating ❑Does Not
systems have outdoor setback
control to lower boiler water ❑Not Observable
temperature based on outdoor ❑Not Applicable
temperature.
403.5.1.1 Heated water circulation systems ❑Complies
[F128]2 have a circulation pump.The Does Not
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
p p pp y ❑Not Applicable
pipe. Gravity and thermos-
circulation systems aretenginaintat'aga:;4::::V00:402•214nRigii:517.0
not present. Controls for
circulating hot water system
pumps start the pump with signal x
for hot water demand within the 1 - _ x, ",
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems i,,,,,,� =` ❑Complies
[FI29]2 comply with IEEE 515.1 or UL ❑Does Not
515.Controls automatically
adjust the energy input to the ❑Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that ❑Complies
[FI30]2 have recirculation pumps that ❑Does Not
pump water from a heated water
supply pipe back to the heated ❑Not Observable
water source through a cold ElNot Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 104°F.
403.5.4 Drain water heat recovery units J ❑Complies
[FI31]2 tested in accordance with CSA ❑Does Not
B55.1. Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units < 3 psi for ❑Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent ❑Complies
[F16]1 fixtures or 75%of permanent ElDoes Not
fixtures have high efficacy lamps.
Does not apply to low-voltage ❑Not Observable
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have ': ❑Complies
[F123]3 no continuous pilot light. ❑Does Not
Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: The Williams Residence Report date: 10/01/18
Data filename: C:\Users\jeb\Documents\Williams.rck Page 8 of 9
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
401.3 Compliance certificate posted. UComplies
[Fl7]2 LiDoes Not
❑Not Observable
❑Not Applicable
303.3 Manufacturer manuals for • LJComplies
[F118]3 mechanical and water heating ❑Does Not
systems have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
•
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: The Williams Residence Report date: 10/01/18
Data filename: C:\Users\jeb\Documents\Williams.rck Page 9 of 9
he 2015 IECC Energy
Efficiency
Certificate
Insulation Rating R-Value
Above-Grade Wall 26.00
Below-Grade Wall 0.00
Floor 30.00
Ceiling / Roof 49.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.30
Door
Heating&Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments