spray foam
NORTH EAST SPRAY FOAM
Williams, Nicole J. ~ 27 Carlton Drive, Queensbury, NY
Williams, Nicole J.
Nov 19, 2018
Letter of Intent
North East Spray Foam will supply and install an Insulation System at Williams, Nicole J. ~ 27 Carlton Drive, Queensbury,
NY
North East Spray Foam will:
1.Prep all Surfaces
2.Mask all Finishes
3.Spray Insulation to a predetermined nominal depth
4.Trim all surfaces necessary, flush to receive other finishes
5.Remove masking and clean work area prior to departure
6.Dispose of all waste in provided receptacle
Notes:
l Prices include one mobilization, should additional mobilizations be required there will be an additional charge.
l Should we arrive and be unable to work, we will charge $150.00 per hour.
l This project is quoted non union/prevailing wage.
l Nominal fill as stated, means that although actual depth may vary within the cavity, mean depth will be approx. as stated.
This fill will meet all methods of installation as stated by the manufacturer.
l According to NYS Building Codes a vapor retarder may be necessary when using this product. Prices do not include a
vapor retarder unless otherwise stated in the contract.
l Ignition or the thermal barriers may be required at the discretion of your Code Enforcement Officer. If not included in
your quote, this will be the responsibility of others.
Supplied by Others:
1.Clear and Empty Space
2.Adequate Power and Lighting
3.Temperature of 55 degrees or greater.
4.Dumpster or other means of waste disposal
5.Reasonable and Safe Access to workplace
North East Spray Foam
7 Rocky Ridge
P.O. Box 471
Warrensburg, NY 12885
4 A Vatrano Road
Albany, NY 12205
---------------------------------------------------------------
518.623.7016
518.623.7015 fax
518.350.2941
518.694.0102 fax
888.472.2774
Initial ____
Bid: 503783
Page 1 of 3
NORTH EAST SPRAY FOAM
Williams, Nicole J. ~ 27 Carlton Drive, Queensbury, NY
Nov 19, 2018
COST:BOARD
FT:
• Closed Cell foam 5.5"
-Apply 5.5 inches of closed cell spray foam to the underside of the roof sheathing.
This is an R-38.1540 1540.00
• Sales Tax
-Warren County Sales Tax.107.80
BID TOTAL 1540 $1,647.80
Initial ____
Bid: 503783
Page 2 of 3
I hereby accept the above quote as a binding contract. I authorize North East Spray Foam to proceed with project specified.
Understanding that ten business days are necessary for proper performance, I would like to schedule this project to start, on
the date of __________________. By scheduling this date with North East Spray Foam I am directing them to proceed per
this proposal and have enclosed a material deposit of 50% of the proposed price. All balances are due on the day of
completion. If payment is not received within ten (10) days of the due date, the Customer will pay a finance charge of an
additional one and one-half percent per month on the past due amount. In the event that payment is not made when due, in
addition to the amount owed and finance charges, the Customer shall also be responsible for the payment of all costs
associated with the collection of the past due amounts including, but no limited to, attorney's fees, court costs and all other
expenses incurred. This agreement constitutes the entire understanding between the parties with respect to the matters set forth
herein and supersedes all prior agreements, arrangements and understandings relating to the subject matter hereof. There are
no representations, warranties, agreements, or understandings, oral or written, between the parties hereto relating to the subject
matter of this agreement except those which are fully expressed herein. When insulating and air sealing your home, mechanical
ventilation is recommended. Blower door test results can determine if mechanical ventilation is necessary. Blower Door Test is
available at a reduced cost upon request. Consult with your Building Analyst for specific details.
Total Board Feet: 1540
Owner / Customer: Williams, Nicole J.
Signed: __________________________________
Print: __________________________________
Date: __________________________________
Initial ____
Bid: 503783
Page 3 of 3
Jobsite Re-Entry & Re-Occupancy
Testing & Third Party Verification
The Evolution of Insulation
Icynene is a leader in pioneering water
blown spray foam insulation. Icynene’s
VOC research extends back to our
early days of product innovation to limit
VOC emissions and other environmental
concerns. Icynene’s product stewardship
has been built around comprehensive
worker training, third party product
testing, and involvement of leading
professionals in the field of occupational
health. Testing and research at the
University of Saskatchewan as early as
1993 show that, with minimal ventilation
(0.3 ACH) homes sprayed with Icynene
were suitable for re-occupancy in 24
hours.
Over the years, Icynene has developed
new products and has continued to
improve its existing products so that the
full line of Icynene spray foams meet the
most stringent VOC guidelines laid out by
the Collaborative for High Performance
Schools (CDPH Standard Method V1.1
[CA Section 01350]). Product certifications
can be found on the Berkeley Analytical
Website (www.berkeleyanalytical.com).
In 2013, a working committee of
the American Chemistry Council –
Center for the Polyurethanes Industry
(ACC-CPI) developed a new protocol
and measurement methods for assessing
emissions from spray foam insulation in a
room size chamber, Icynene was quick to
use this facility for the next phase in product
development. Since then, developments
have been fast and furious.
Four Phases of Testing & Evaluation
Icynene immediately enlisted the help of the
lead researcher on the ACC-CPI project
to carry out the studies on its products.
In addition, a leading PhD toxicologist
was hired to review all results and provide
checks and oversight on the findings.
PHASE I : Re-Entry Testing (12 hour)
PURPOSE: Investigate whether a
combination of natural ventilation (e.g.
open windows) together with a small fan
provides enough ventilation for worker
re-entry without protection in less than
24 hours.
FINDINGS: Ventilation rate of as little
as 1.0 ACH would allow workers to
re-enter the work space in as little as
12 hours after spray.
RELEVANCE: Findings meant crews
could spray a new home one day and
other trades could re-enter the space
the next morning.
PHASE II: Re-Entry Testing (4 hour)
PURPOSE: Focus on whether increased
ventilation rates can permit even faster
re-entry. Ventilation rates were increased
to 10ACH and emissions were again
measured and assessed.
FINDINGS: Results indicated that
after four (4) hours the work area was
suitable for re-entry by trades (with
ventilation rate of 10 ACH).
RELEVANCE: Findings meant that on
jobsites that operate around the clock
(e.g. commercial construction) spray
activities could be arranged so that
other trades could be brought into the
spray area in as little as 4 hours after
spray without needing PPE.
DEFINITIONS
Re-entry is entry into the work
zone without requirement for
PPE for the resumption of trades
work during a normal 8 hour
work day. Re-occupancy is the
permanent, 24-hours-per-day
return into the space by building
owners/occupants.
RE-ENTRY AND
RE-OCCUPANCY PERIODS
Times based upon ventilating
during and after a spray application.
Ventilation Rate
(Air Changes per
Hour)
Re-entry period
for sprayers,
helpers,
informed trade
workers &
contractors
At 0.3 ACH 24 hours
At 1.0 ACH 12 hours*
At 10.0 ACH 4 hours*
At 40.0 ACH 1 hour**
Ventilation Rate
(Air Changes per
Hour)
Re-occupancy
period for all
others
At 0.3 ACH 24 hours
At 1.0 ACH 24 hours
At 10.0 ACH 24 hours
At 40.0 ACH 2 hours**
* Twelve (12) and four (4) hour re-
entry for trades applies to all Icynene
products sold in the United States.
** One (1) hour re-entry and two (2)
hour re-occupancy applies only to
Low VOC products (Icynene Classic
Max and Icynene ProSeal).
The Evolution of Insulation
Icynene Inc. 6747 Campobello Road
Mississauga, Ontario L5N 2L7 Canada
Ph: 1.800.758.7325 • ICYNENE.COM
At this point, the team realized
that formulation changes might
be needed to allow re-occupancy
times to be reduced for permanent
building occupants (i.e. homeowners)
because requirements are naturally
much stricter for family re-occupancy
than for trades re-entry. Icynene
Formulation Chemists were brought in
to make adjustments to formulations
to eliminate the tiny concentration
of components (emissive catalysts)
that were preventing a reduction in
re-occupancy times.
PHASE III: Re-Entry and
Re-Occupancy Testing (4 hour)
PURPOSE: Review performance
of a combination of revised product
formulations and increased ventilation
rates. Ventilation rates were increased
to a rate of 40.0 ACH to help meet a
more stringent standard.
FINDINGS: VOC emissions were
low enough that, not only could
workers re-enter the space without
protection after four (4) hours,
the space could be permanently
reoccupied also.
FOLLOW UP: Concentrations of the
catalysts were at the lowest limits
of the measurement methodology.
The team had to employ other tests
to confirm that the low results were
really indicative of low emissions. The
team believed that the results were
encouraging enough that additional
testing might show spaces were
suitable in less than 4 hours.
PHASE IV: Re-Entry (1 hour) and
Re-Occupancy Testing (2 hour)
PURPOSE: Extend Phase III
testing and explore health concerns
pertaining to VOC emissions, fire
retardant emissions and unreacted
isocyanates.
FINDINGS: Testing confirmed that
with 40 ACH ventilation and with use of
Icynene’s ultra-low VOC products, the
work area was safe for re-occupancy
after two (2) hours and unprotected
trades can enter the work area after (1)
hour.
RELEVANCE: Confirmed that
homeowners do not have to vacate
their buildings overnight if a home
is sprayed during the day. Further,
it raises the possibility that Icynene
contractors can vacate jobsites within
hours after completing spray activities.
For more information, contact Icynene on 1-800-758-7325 .