Case Number:RC-0585-2018Case Module:Permit
Inspection Date:10/24/2018Inspection Status:Failed
Inspector:John O'BrienInspection Type:Building Framing
Job Address:27 CARLTON DRParcel Number:296.17-1-28
Queensbury, NY 12804
Contact TypeCompany NameName
ContractorWilliams, Thomas
Primary OwnerWilliams, Thomas
Granted PermissionWilliams, Nicole
Primary OwnerWilliams, Nicole
ApplicantWilliams, Nicole
Checklist ItemPassedComments
Building Inspector NotesNO10/24/18 Preliminary Framing Inspection Not Approved
- Discussed the following items with the homeowner Mr.
Williams.
1) Anchor the Floor System ledger boards with concrete
expansion anchors as discussed along with pressure
treated blocking under the ledger to existing concrete
floor.
For additional bearing.
2) Add collar ties to existing 2"x4" rafters
3) Fur out all exterior walls to accept R21 insulation
4) Complete Framing at front window including concrete
anchors. Replace existing exterior sheathing at this
location as discussed.
5) Once the items listed above are complete call for a
framing recheck.
Oct 24, 2018Page (1)
INSPECTION WORKSHEET (BINS-007531-2018)
Checklist ItemPassedComments
FramingNO10/24/18 Preliminary Framing Inspection Not Approved
- Discussed the following items with the homeowner Mr.
Williams.
1) Anchor the Floor System ledger boards with concrete
expansion anchors as discussed along with pressure
treated blocking under the ledger to existing concrete
floor.
For additional bearing.
2) Add collar ties to existing 2"x4" rafters
3) Fur out all exterior walls to accept R21 insulation
4) Complete Framing at front window including concrete
anchors. Replace existing exterior sheathing at this
location as discussed.
5) Once the items listed above are complete call for a
framing recheck.
Attic Access 22 x 30 minimumNO
Jack Studs HeadersNO
Continuous Header for Garage Doors with StrapingNO
Truss Specification ProvidedNO
Bracing BridgingNO
Hurricane Clips/Uplift Screws/Nail Holes FilledNO
Air Seal all Plates and SillsNO
Air Seal All Registers at FloorNO
Air Sealing all Joints Before InsulationNO
Joist hangersNO
Jack Posts Main BeamsNO
Exterior sheeting nailed properlyNO
12 O.C.NO
Headroom 6 ft. 8 in.NO
Notches Holes Bearing WallsNO
Metal Strapping for Notches Top PlateNO
Draft stopping 1,000 sq. ft. floor trussesNO
Anchor Bolts 6 ft. or less on centerNO
Ice and water shield 24 inches from wallNO
Oct 24, 2018Page (2)
INSPECTION WORKSHEET (BINS-007531-2018)
Checklist ItemPassedComments
Soffits-Insulation BaffelNO
Windows Habitable Space BedroomsNO
24 in. (H)NO
20 in. (W)NO
5.7 sf above below gradeNO
5.0 sf gradeNO
Design Professional Sign-off, if requiredNO