Loading...
BINS-007531-2018 10242018 INSPECTION WORKSHEET (BINS-007531-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0585-2018Case Module:Permit Inspection Date:10/24/2018Inspection Status:Failed Inspector:John O'BrienInspection Type:Building Framing Job Address:27 CARLTON DRParcel Number:296.17-1-28 Queensbury, NY 12804 Contact TypeCompany NameName ContractorWilliams, Thomas Primary OwnerWilliams, Thomas Granted PermissionWilliams, Nicole Primary OwnerWilliams, Nicole ApplicantWilliams, Nicole Checklist ItemPassedComments Building Inspector NotesNO10/24/18 Preliminary Framing Inspection Not Approved - Discussed the following items with the homeowner Mr. Williams. 1) Anchor the Floor System ledger boards with concrete expansion anchors as discussed along with pressure treated blocking under the ledger to existing concrete floor. For additional bearing. 2) Add collar ties to existing 2"x4" rafters 3) Fur out all exterior walls to accept R21 insulation 4) Complete Framing at front window including concrete anchors. Replace existing exterior sheathing at this location as discussed. 5) Once the items listed above are complete call for a framing recheck. Oct 24, 2018Page (1) INSPECTION WORKSHEET (BINS-007531-2018) Checklist ItemPassedComments FramingNO10/24/18 Preliminary Framing Inspection Not Approved - Discussed the following items with the homeowner Mr. Williams. 1) Anchor the Floor System ledger boards with concrete expansion anchors as discussed along with pressure treated blocking under the ledger to existing concrete floor. For additional bearing. 2) Add collar ties to existing 2"x4" rafters 3) Fur out all exterior walls to accept R21 insulation 4) Complete Framing at front window including concrete anchors. Replace existing exterior sheathing at this location as discussed. 5) Once the items listed above are complete call for a framing recheck. Attic Access 22 x 30 minimumNO Jack Studs HeadersNO Continuous Header for Garage Doors with StrapingNO Truss Specification ProvidedNO Bracing BridgingNO Hurricane Clips/Uplift Screws/Nail Holes FilledNO Air Seal all Plates and SillsNO Air Seal All Registers at FloorNO Air Sealing all Joints Before InsulationNO Joist hangersNO Jack Posts Main BeamsNO Exterior sheeting nailed properlyNO 12 O.C.NO Headroom 6 ft. 8 in.NO Notches Holes Bearing WallsNO Metal Strapping for Notches Top PlateNO Draft stopping 1,000 sq. ft. floor trussesNO Anchor Bolts 6 ft. or less on centerNO Ice and water shield 24 inches from wallNO Oct 24, 2018Page (2) INSPECTION WORKSHEET (BINS-007531-2018) Checklist ItemPassedComments Soffits-Insulation BaffelNO Windows Habitable Space BedroomsNO 24 in. (H)NO 20 in. (W)NO 5.7 sf above below gradeNO 5.0 sf gradeNO Design Professional Sign-off, if requiredNO O'Brien, John (Inspector) Oct 24, 2018Page (3)