Loading...
BINS-008159-2018 11192018 INSPECTION WORKSHEET (BINS-008159-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0585-2018Case Module:Permit Inspection Date:11/19/2018Inspection Status:Partial Pass Inspector:John O'BrienInspection Type:Building Framing Job Address:27 CARLTON DRParcel Number:296.17-1-28 Queensbury, NY 12804 Contact TypeCompany NameName ContractorWilliams, Thomas Primary OwnerWilliams, Nicole ApplicantWilliams, Nicole Granted PermissionWilliams, Nicole Primary OwnerWilliams, Thomas Checklist ItemPassedComments Building Inspector NotesNO10/24/18 Preliminary Framing Inspection Not Approved - Discussed the following items with the homeowner Mr. Williams. 1) Anchor the Floor System ledger boards with concrete expansion anchors as discussed along with pressure treated blocking under the ledger to existing concrete floor. For additional bearing. 2) Add collar ties to existing 2"x4" rafters 3) Fur out all exterior walls to accept R21 insulation 4) Complete Framing at front window including concrete anchors. Replace existing exterior sheathing at this location as discussed. 5) Once the items listed above are complete call for a framing recheck. 11/19/18 Framing Partial Approval - Floor only! Nov 19, 2018Page (1) INSPECTION WORKSHEET (BINS-008159-2018) Checklist ItemPassedComments FramingNO10/24/18 Preliminary Framing Inspection Not Approved - Discussed the following items with the homeowner Mr. Williams. 1) Anchor the Floor System ledger boards with concrete expansion anchors as discussed along with pressure treated blocking under the ledger to existing concrete floor. For additional bearing. 2) Add collar ties to existing 2"x4" rafters 3) Fur out all exterior walls to accept R21 insulation 4) Complete Framing at front window including concrete anchors. Replace existing exterior sheathing at this location as discussed. 5) Once the items listed above are complete call for a framing recheck. 11/19/18 Framing Partial Approval - Floor only! Jack Studs HeadersNO Continuous Header for Garage Doors with StrapingNO Truss Specification ProvidedNO Bracing BridgingYES11/19/18 Framing Partial Approval - Floor only! Hurricane Clips/Uplift Screws/Nail Holes FilledNO Air Seal all Plates and SillsNO Air Seal All Registers at FloorNO Air Sealing all Joints Before InsulationNO Joist hangersNO11/19/18 Framing Partial Approval - Floor only! Jack Posts Main BeamsNO Exterior sheeting nailed properlyNO 12 O.C.NO Headroom 6 ft. 8 in.NO Notches Holes Bearing WallsNO Metal Strapping for Notches Top PlateNO Draft stopping 1,000 sq. ft. floor trussesNO Anchor Bolts 6 ft. or less on centerNO Ice and water shield 24 inches from wallNO Soffits-Insulation BaffelNO Windows Habitable Space BedroomsNO 24 in. (H)NO 20 in. (W)NO 5.7 sf above below gradeNO 5.0 sf gradeNO Nov 19, 2018Page (2) INSPECTION WORKSHEET (BINS-008159-2018) Checklist ItemPassedComments Design Professional Sign-off, if requiredNO O'Brien, John (Inspector) Nov 19, 2018Page (3)