2008-302 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number. P20080302 Date Issued: Monday, October 20, 2008
This is to certify that work requested to be done as shown by Permit Number P20080302
has been completed.
Location: 40 EVERTS Ave
Tax Map Number. 523400-302-008-0002-079-000-0000
Owner. TIMOTHY & LINDA HARRINGTON
Applicant: TIMOTHY & LINDA HARRINGTON
This structure may be occupied as a:
Residential Addition By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the ` `� +f /'*
property owner of the responsibility for compliance with Site Plan, r V '
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Qmensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20080302 Application Number. A20080302
Tax Map No: 523400-302-008-0002-079-000-0000
Permission is hereby granted to: TIMOTHY& LINDA HARRINGTON
For property located at: 40 EVERTS Ave
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: TIMOTHY & LINDA HARRINGTO
40 EVERTS Ave Residential Addition $50,000.00
QUEENSBURY, NY 12804 Total value $50,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
TODD MARTIN
FOUNDERS WAY
QUEENSBURY, NY 12804-0000
Plans &Specifications
2008-302
480 SQ FT RESIDENTIAL ADDITION
$75.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Saturday,June 27, 2009
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town Que Y�, ,June 27,2008
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
2 `5�1 T �rQFFICE USE ONLY
1 _
' 77 ,
TAX MAP NO. PERMIT NO.
FEES: PERMIT RECREATION w
ENGINEERING
(If applicable) 10 ")P
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
APPLICANT/BUILDER: y.��77 NA W n-T1 kJ OWNER: -Rtil `� L-i+-�i> t-F4(Li?►^'ta`T��
ADDRESS: I'�6 F--o y NJ S tN ✓�� ADDRESS: t{0 IEVr=:&i S AV F-
PHONE NOSj Oft Scot-ZZz q PHONE NOS. I - 0 '5 S
CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: PHONE:
LOCATION OF PROPERTY: too et<En
SUBDIVISION NAME:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT z
0 do �-
APPLY TO YOUR z Ct O d w
PROJECT O r H 7s)
¢ a = v� " emu_ F- o �? z
z Q ¢ � � NU) 0LL F- LL a.. ios
r rr
SINGLE FAMILY E4 so
TWO-FAMILY
MULTI-FAMILY
(NO. of UNITS )
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(1,2,3)
OTHER
IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS:
ESTIMATED CONSTRUCTION COST: 5 O, o a FUEL TYPE:
HEAT TYPE: 6,0 , "HOW MANY FIREPLACE(S): O AND/OR WOODSTOVES(S): O
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE?
IS THIS A HISTORIC SITE? M O
PROPOSED USE OF BUILDING OR ADDITION: T3et> t2oo r4 F3 AT49c>0 CL0 S�T
*Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office g 3-LGL 11-05
Town of Queensbury - Community Development Office • 742 Bay Road, Queensbury, NY 12804
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN?
ARE THERE EASEMENTS ON PROPERTY? 1J U
Fdge no construction activities shall be commenced prior to issuance of a valid
ertify that the application, plans, and supporting materials are a true and
tatement/description of the work proposed, that all work will be performed in
e with the NY State Building Codes, local building laws and ordinances, and in
ce with local zoning regulations. I acknowledge that prior to occupying the
oposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above.
Signed VIA ri-x IL
Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction
codes or septic systems)
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
.....................
Permission is hereby granted to the above This application / proposed action described
Applicant to erect or alter the building S herein is found to be in accordance with the
described herein in accordance with said zoning Laws of the Town of Queensbury.
Application: 00
; ;
/
/
I I ,
/
r 0 I
I I ,
I I / I
I , I 0
BUILDING & CODES APPROVAL o ZONING APPROVAL 11
I
I
DAT ; oo DATE
0 ..................... ................................
QUESTIONS? CALL 761-8256 OR EMAIL
codesCaD-gueensbury.net
Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION
www.ciueensbury.net
Operating Permit Issue
d: Yes �No Occupancy Type:
Construction Classification:Q�
Assembly Occupancy Limit:
Special Conditions:
QTou7n of Queensburyj - Community Development Office - 742 Bay Road, Queensbury, NY 12804
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518)761-8256 Arrive: l7 a rr>(�
Date Inspection request received: 1140 : Inspector s Initial _ part: a
' s•
NAME: t t " P IT
LOCATION: Vim- E:
TYPE OF STRUCTURE:
Comments:
Y No WA
4' Building Number Address visible from road
Chimney Height/'B'Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent throwh roof minimum 6 inches
Roof Complete/Exterior Finish Complete V
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 indhes above grade
Guard at stairwell at 34 inches or more
Guard at deck,pordies 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/ExWW Railings 34 inches to 38 inches
Deck Bras /Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas ct e /regulator 18 inches above grade
I nor /doors I main entrance 36 inches
Bath watertight
/Window in staff welis safety glazing
Interior Smoke De 1 Carbon Mo
oxide Detectors
Every level: EveyBed
Outside every bedroom afea: �* r/
Inter Connected: / eaftmbadcup: ��z
Attic access 30 inches x 22 inches x 30 inches in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.it-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fodures
Foundation insulation
Floor buss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace stwt-off within 30 feet or within One of site
Oil Furnace shut-off at entrance to furnace area
FumaceMot Water Heater operaft
Low water shut-off bodes
Relief Va s installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrodk Underside minimum W Gypsum
Basement stairs dosed rise>4 inches
Garage Floor'Pitched
Garage fireproofing/%hour fire door/door closer
Duct worts Sealed
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Arc Fault Breaker in Bedrooms
Flex Gas Pipe Bondi
As Built Septic System/Sewer Dept.Ins Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C 10 Tem /Permanent
L folding&Codes FomhslBudding&CodesUnspection Forms%Residential Final Inspection Form revised_100405.doc;Revised
January 7,2008
Rough Plumbing / Insulation Inspection port
Office No. (518) 761-8256 Date In ecti9a-r t e
Queensbury Building &Code Enforcement Arrive. o a rt: arp
742 Bay Road, Queensbury, NY 12804 Inspector's Iniha
NAME: PER IT#:
LOCATION: �- ` f _ , - INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbing/Nail Plates
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
P essure Test
Supply Piping
-r d
P.&I fo 15 minutes
1 sidential Check/Commercial Check
ek o ' ilar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/ Hot Water Piping Insulation
If required unheated spaces p
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
.
COMME S: F w- w-
Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008
mod, e-/0,,
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Ins st iv 9
Queensbury Building&Code Enforcement Arrive: rt: a
742 Bay Road, Queensbury, NY 12804 Inspector's Initta "
F
NAME: .�D RMIT
LOCATION: 6 SPECT ON:
TYPE OF STRUCTURE: d v J2--
Y N NIA COMMENTS:
q
Attic ccess 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers � �
Jack Posts/Main Beams
Exterior sheeting nailed properly �
12"O.C. �
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
're separation 1, 2, 3 hour
M7VFIre waill2,.3,.4�hour
--
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceilingtwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (V11)
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Fortes-QLD\Building&CodesUspection ForrnsTnaming Firestopping inspection ReporLdoc Revised January 7,2008
COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.
Main Office 176 Doe Run Road-Manheim,PA 17545
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL
Permit No. .. Z....Cert. N2 - 74 510 Cut-in Card No.....................................
Owner.......`.`......1.. ...... ! 1�.1��f �2. !' ............................................................... ..... .............
Location.`�().....C �4..ot:C5..........�i�......................................................... .r�.............
�+ rz� 2 3
Installation Consisting of.... ....T.f !!.............. ..................... .../.............................. ..........................
....PAYM4...��F.f.}i 3......................................................................................................................
....................................................................................................................................................................................
InstalledBy..... ..'.. ..�.........................................................Lic.No...................................................
The conditions following governed the issuance of this certificate,and any certificate previously issued is
cancelled:-
This certificate only covers the electrical equipment and installation conditions as of date. Upon the
introduction of additional equipment or alterations,application shall be promptly made for inspection.
Inspectors of this Company shall have the privile e m mg i spections at any time, and if its
rules are violated,the Companyshall have the right re js cert ficate.
Date... 4-1.9(...J...r............... INSPECTOR........... ...� ....................................................................
-...I...-I D A I A C l
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date In ection r u rlea--Zax-
aQueensbury Building & Code Enforcement Arrive: a rt: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's In a s `
NAME: PEE`ZIy11T#:
LOCATION: 1-6D IN ECT ON: � } ,
TYPE OF STRUCTURE:
fF � . .
Y N N/A
MR?—in Place
1 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
.Ventd
;.,,I
S.I. 0 0 ft. above highest connection for 15 minutes
Pre est
Water Supply Piping
'r/Head
50 P.S.1 for 15 minutes
I n/Residential Check/Commercial Check
Exterior Sealant
ro r vent, Atfic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation Report.revised Nov 17 2003, rinsed February 15,2005, revised January 7,2008
Framing / Firestopping Inspection eport
Office No. (518) 761-8256 Date Ins request received:
Queensbury Building &Code Enforcement Arrive. -iv am/�n , Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspecto s Initials: _
NAME: PERMIT# rW—
LOCATIOW S INSPECT ON:
TYPE OF STRUCTURE:
Framing Y N N/A COMMENTS:
Attic Access 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/2 w 16 gauge 8 16D Haas each side
Draft stopping 1,000 sq. ft. floor trusses
-Ancer bolts or less on center
Ice and water sh' Id 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceilingtwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Forms-01-Muilding&Codesvnspection FormTrarning Firestopping inspection Reportdoc Revised January 7,2008
A)
Foundation Inspection Report
Office No.(518)761-8256 Date In do request received:
Queensbury Building&Code Enforcement Arrive: am/MC Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspect Initials:
NAME: PERMIT#:
LOCATION: INSPECT ON:
s9qc
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
enforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
me above footing
Or 6 '1 for wet areas under slab
Backfill roval
umbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Fonms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
2 -Z/ �r_sj_a_7
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/Tp�
Depart� m
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT#: C�v ,302_
LOCATION: INSPECT ON: - 2 -e�k
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
iers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place A 1
Footing Dowels o Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\lnspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
�-rr r�rr-------- -.
..r� 1
t �
Communihj Development Office
"''"'S' own of Queensbury - 742 Bay Road ■ Queensbury, New York •12804 '
Marilyn Ryba,Executive Director• David Hatin, Director of Building&Codes
Crai;,Brown,Zoning Administrator ;
-----------------
BUILDING PERMIT CALCULATION SHEETS OM -` !I NDA 4ARRI NGTON
PLAN - 08-0101
NATURAL LIGHT, VENTILATION AND EMERGENCY EGRESS REQUIREMENTS
AREA OF ROOM IN ACTUAL LIGHT REQUIRED ACTUAL SQUARE FOOT
HABITABLE ROOM SQUARE FEET SQUARE FOOTAGE VENTILATION-4% VENTILATION OPENING FOR REMARKS
OF ROOM AREA SQUARE FOOTAGE EGRESS
BED ROOM ?-6$.7S6 54.64 10.7 5' 2 2.92 5.7
v V
QUESTIONS? CALL 761-8256 OR EMAIL
codesOgueensburv.net
VISIT OUR WESSITE FOR MORE INFORMATION
www.guensbury.net
1---E-------------------i.
a_ =7711
ity Development Office ;
ueensbury 742 Bay Road • Queensbury, New York •1280411
Marilyn Ryba, Executive Director•David Hatin, Director of Building&Codes ;
Craig Brown,Zoning Administrator ;
WINDOW SCHEDULE
PLA td ,* O 8-6 I D l
JOB SITE/ADDRESS:__4o_L_VERms ��� _____DATE:___YV_�___�__
OWNER: _��M '1-1 Naga _.t rnL3.r G r —APPLICATION NO.:_____�_�___!___
WINDOW- UNIT OR CLEAR CLEAR
WINDOW STOCK ROUGH ROUGH SQ.FT. OPENING
NO.OR WINDOW SQ.FT. OPENING SPECIAL HARDWARE OR
WIDTH IN
MANUFACTURER NUMBER OPENING OPENING EGRESS/CLEAR HEIGHT
LETTER NAME MODEUTYPE CALL WIDTH HEIGHT VENT OPENING IN INSTRUCTIONS
ON PLAN SIZE INCHES INCHES
A ANr->Et?SFN DN ,-W3644 3-'Zig 4L818 5,73 .5,70 '.�3 �8 24/4
g Atv DER 5 F_N �y rn3a4-2 6; 4$ $�t X4 /b 4� ,5,76 3 3�g 2 444
DE �N D l4 `lW3,032 3�2�B 314%8 3.8 5' 3.82 3 3 6 G LA�-rC—M PER
tw Z>
D ANS?ERSE-t-t GLIDING G32 3-0 /1 l/ /.70 /,745 7 /8
1
CREScheck Software Version 4.1.4
NJ( Compliance Certificate
Project Title: TIM & LINDA HARRINGTON
Report Date:06/04/08
Data filename:Untitled.rck
Energy Code: 2007 New York Energy Conservation
Construction Code
Location: Warren County,New York
Construction Type: Detached 1 or 2 Family
Heating Type: Non-Electric
Glazing Area Percentage: 11%
Heating Degree Days: 7635
Construction Site: Owner/Agent: Designer/Seelpm0mr--
40 Everts Avenue Tim$Linda Harrington G.Peter Jensen
Queensbury,NY 12804 40 Everts Avenue 17 West Road
Queensbury,NY 12804 South Glens Falls,NY 12803
(518)798-3859
Compliance:7.6°/.Better Than Code Maximum UA:118 Your UA:109
Gross Cavity Cont. Glazing LIA
Assembly Area or R-Value R-Value or D..
Perimeter U-Factor
Ceiling 1:Flat Ceiling or Scissor Truss 480 38.0 0.0 14
Wall 1:Wood Frame,16"o.c. 782 21.0 0.0 40
Window 1:Wood Frame-Double Pane with Low-E 89 0.340 30
Basement Wall 1:Solid Concrete or Masonry 272 13.0 0.0 25
Wall height:5.0'
Depth below grade:4.0'
Insulation depth:3.6
The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted
with this permit application.The proposed systems have been designed to meet the 2007 New York Energy Conservation Construction
Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her
knowledge,belief,and professional judgment,such plans or specifications are in complianpe with this Code.
G. PETER JENSEN D D
Name-Title 17 Wft5T HUAUig tore Date
SOUTH GLENS FALLS
NEW YORK 12803
Project Notes: (518)798-3859 \�joSS ARC'S'i
Addition to Cf Q�ZER JFi,
Single Family Residence �� r-y E`y
Plan 08-0101
;P 0?8-0ZD Q`E
r'rF OF KEW�O
Project Title:TIM&LINDA HARRINGTON Report date:06/04/08
Data filename: Untitled.rck Page 1 of 4
CREScheck Software Version 4.1.4
NJ( Inspection Checklist
Date:06/04/08
Ceilings:
❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation
Comments:
Above-Grade Walls:
❑ Wall 1:Wood Frame,16"o.c.,R-21.0 cavity insulation
Comments:
Basement Walls:
❑ Basement Wall 1:Solid Concrete or Masonry,5.0'ht/4.9 bg/3.5'insul,R-13.0 cavity insulation
Comments:
Windows:
❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Air Leakage:
❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible
materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation.
Vapor Retarder:
❑ Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment are identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
❑ Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications.
❑ Insulation is installed according to manufacturer's instructions,in substantial contact with the surface beini insulated,and in a manner
that achieves the rated R-value without compressing the insulation.
Duct Insulation:
❑ Supply ducts in unconditioned attics or outside the building are insulated to at least R-11.
❑ Return ducts in unconditioned attics or outside the building are insulated to at least R-6.
❑ Supply ducts in unconditioned spaces are insulated to at least R-11.
❑ Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements.
Duct Construction:
❑ All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,or
tapes.Tapes and mastics are rated UL 181A or UL 181B.
Exceptions:
Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa).
❑ The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
❑ Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set pant of the largest zone.
Project Title:TIM&LINDA HARRINGTON _w Report date:06/04/08
Data filename: Untitled.rck Page 2 of 4
Electric Systems:
Separate electric meters exist for each dwelling unit.
Fireplaces:
0 Fireplaces are installed with tight fitting non-combustible fireplace doors.
Lj Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York
State,the Residential Code of New York State or the New York City Building Code,as applicable.
Service Water Heating:
Lj Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or
Is part of a circulating system.
Lj Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
Lj All heated swimming pools have an onloff heater switch and a cover unless over 20%of the heating energy is from non-depletable
sources.Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
Project Title:TIM&LINDA HARRINGTON Report date:06/04/08
Data filename: Urititled.rck Page 3 of 4
Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes
" Insulation Thickness in Inches by Pipe Sizes
Non-Circulating Runouts Circulating Mains and Runouts
Heated Water Temperature("F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-169 0.5 0.5 1.0 1.5
100-139 0.5 0.5 0.5 1.0
Table 2:Minimum Insulation Thickness for HVAC Pipes
Fluid Temp. insulation Thickness in Inches by Pipe Sizes
Piping System Types Range("F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4"
Heating Systems
Law Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0
Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD:(Building Department Use Only)
Project Title:TIM&LINDA HARRINGTON _ r Report date:06/04/08
Data filename: Untitled.rck Page 4 of 4