Loading...
air balance reportMJL ADTEK Enterprises, LLC P.O. Box 503, Clifton Park, NY 12065 Phone: (518) 376-9478 Date: Prepared by: Engineer: Contractor: Queensbury, New York 12804 Bohler Engineering Hunt Companies, Inc. 741 Upper Glen Street Project: HVAC SYSTEMS TESTING: Air and Water Balance Report for Taco Bell Michael J. Lucarelli December 22, 2019 17 Computer Drive W. Albany, New York 12205 515A County Route 45 Argyle, New York 12809 Location: Project: Address: DATE: PROJECT # :M7101 THE DATA PRESENTED IN THIS REPORT IS AN EXACT RECORD OF SYSTEM PERFORMANCE AND WAS OBTAINED IN ACCORDANCE WITH NEBB STANDARD PROCEDURES. ANY VARIANCES FROM DESIGNED QUANTITIES WHICH EXCEEDS NEBB TOLERANCES ARE NOTED THROUGHOUT THIS REPORT. THE AIR DISTRIBUTION SYSTEMS HAVE BEEN TESTED & BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH NEBB "PROCEDURAL STANDARDS FOR TESTING AND BALANCING OF ENVIRONMENTAL SYSTEMS" AND THE PROJECT SPECIFICATIONS. THE WATER DISTRIBUTION SYSTEMS HAVE BEEN TESTED & BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH NEBB "PROCEDURAL STANDARDS FOR TESTING AND BALANCING OF ENVIRONMENTAL SYSTEMS" AND THE PROJECT SPECIFICATIONS. CERTIFICATION 741 Upper Glen Street Queensbury, New York 12804 Taco Bell MJL ADTEK Enterprises, LLC.TESTING AND BALANCING FIRM: BALANCED BY: SIGNATURE: 12/22/2019 Michael J. Lucarelli Michael J. Lucarelli CD - Ceiling Diffuser CS - Circuit Setter DD - Direct Drive ER - Exhaust Register LD - Linear Diffuser NA - Not Accessible ND - No Volume Damper NG - No Gauges NI - Not Installed NR - Not Required NS - Not Specified OBD - Opposed Blade Damper OD - Open Duct RG - Return Grille SR - Supply Register SD - Supply Diffuser TP- Thermally Protected EP-Electronically Protected WMS - Wire Mesh Screen NN - Diffuser, Register or Grille Noisy: All available adjustments made to correct condition. Additonal Dampers, sound lining or duct change required to correct condition. MJL ADTEK Enterprises, LLC P.O. Box 503, Clifton Park, NY 12065 Phone: (518) 376-9478 Following are code definitions as used in a balancing report: PROJECT NAME: ADDRESS: ACTUAL NA 3375 2614 761 1.35 0.54 0.81 778 MARATHON 3.0 3 211/212/211 6.3/6.4/6.2 1725 1.15 BREAKER Remarks: NS NS GE 2.0 3 211/212/211 5.3/5.7/5.4 1725 1.15 NS NS 3 200 6.3 TOTAL PAGES:6 MJL ADTEK Enterprises, LLC Phone: (518) 376-9478 P.O. Box 503, Clifton Park, NY 12065 PAGE NUMBER:1 Taco Bell 741 Upper Glen Street Queensbury, New York 12804 PROJECT NUMBER:M7101 12/22/2019DATE: AIR MOVING EQUIPMENT TEST SHEET SYSTEM EQUIPMENT LOCATON AREA SERVICED EQUIPMENT MANUFACTURER MODEL RTU-2 ROOF DINING AREA TRANE YHC092A3RHA2H RTU-1 ROOF FOOD PREP TRANE GBC180A3EHA03 NS SERIAL NUMBER TOTAL CFM-FAN TOTAL CFM-OUTLET R/A CFM O/A CFM 725102664L19441707JA SPECIFIED ACTUAL NS NA NS 0.41 INLET PRESSURE DISCHARGE PRESSURE TOTAL STATIC PRESSURE NS NS NS 932 SPECIFIED NS NS NS NS NS NS NS NS 2548 2070 478 NS 1.41 1 NS MOTOR MANUFACTURER MOTOR HP/BHP PHASE VOLTAGE FAN RPM NS NS 3 208 9.4 NS NS AMPERAGE MOTOR RPM MOTOR SERVICE FACTOR STARTER HEATER ELEMENTS NS NS BREAKER MOTOR SHEAVE & NO. GROOVES FAN SHEAVE & NO. GROOVES BELTS 1VL40 x 7/8" (0% CL) BK80 x 1-7/16" BX44 1VL40 x 7/8" (50%CL) AK59 x 1" AX35 TYPE SIZE Ak FPM CFM TEST 1 TEST 2 TEST 3 FPM CFM RTU-1 SUPPLY 1 DISHWASHER CD 12"RD 1.0 HOOD NS 762 699 NR HOOD 699(2) 2 DISHWASHER CD 12"RD 1.0 HOOD NS 89 76 NR HOOD 76(2) 3 MANAGERS OFFICE CD 6"RD 1.0 HOOD NS 186 173 NR HOOD 173(2) 4 ELECTRICAL CD 6"RD 1.0 HOOD NS 191 167 NR HOOD 167(2) 5 KITCHEN HOOD CD 14"RD 1.0 HOOD NS 381 366 NR HOOD 366(2) 6 FOOD PREP CD 12"RD 1.0 HOOD NS 269 357 NR HOOD 357(2) 7 FOOD PREP CD 12"RD 1.0 HOOD NS 483 402 NR HOOD 402(2) 8 FOOD PREP CD 10"RD 1.0 HOOD NS 0 0 NR HOOD 0(1) 9 FOOD PREP CD 12"RD 1.0 HOOD NS 479 403 NR HOOD 403(2) 10 DRIVE THRU CD 12"RD 1.0 HOOD NS 832 732 NR HOOD 732(2) TOTAL NS TOTAL 3375 RETURN 1 DRIVE THRU RG 18"RD 1.0 HOOD NS 1010 1292 NR HOOD 1292 2 DISHWASHER RG 16"RD 1.0 HOOD NS 450 606 NR HOOD 606 3 DISHWASHER RG 16"RD 1.0 HOOD NS 518 716 NR HOOD 716 TOTAL NS TOTAL 2614 Remarks:(1) Connected to existing exhaust. (2) Existing duct work. No access to duct work above ceiling. No OBD's in face of grille. PAGE NUMBER: TOTAL PAGES: 2 6 FINAL AIR DISTRIBUTION TEST SHEET TERMINAL NUMBER ROOM NUMBER TERMINAL DESIGN TEST-FPM or CFM ADDRESS: MJL ADTEK Enterprises, LLC P.O. Box 503, Clifton Park, NY 12065 Phone: (518) 376-9478 PROJECT NAME: Taco Bell Queensbury, New York 12804 741 Upper Glen Street PROJECT NUMBER:M7101 12/22/2019DATE: TYPE SIZE Ak FPM CFM TEST 1 TEST 2 TEST 3 FPM CFM RTU-2 SUPPLY 1 DINING CD 10"RD 1.0 HOOD NS 342 331 NR HOOD 331 2 DINING CD 10"RD 1.0 HOOD NS 319 313 NR HOOD 313 3 DINING CD 10"RD 1.0 HOOD NS 337 341 NR HOOD 341 4 DINING CD 10"RD 1.0 HOOD NS 289 297 NR HOOD 297 5 DINING CD 10"RD 1.0 HOOD NS 231 257 NR HOOD 257 6 DINING CD 10"RD 1.0 HOOD NS 300 314 NR HOOD 314 7 DINING CD 10"RD 1.0 HOOD NS 328 313 NR HOOD 313 8 WOMEN'S ROOM CD 8"RD 1.0 HOOD NS 100 91 NR HOOD 91 9 MEN'S ROOM CD 8"RD 1.0 HOOD NS 114 96 NR HOOD 96 10 VESTIBULE CD 10"RD 1.0 HOOD NS 184 195 NR HOOD 195 TOTAL NS TOTAL 2548 RETURN 1 DINING CD 10"RD 1.0 HOOD NS 1110 1106 NR HOOD 1106 2 DINING CD 10"RD 1.0 HOOD NS 956 964 NR HOOD 964 TOTAL NS TOTAL 2070 Remarks: FINAL Queensbury, New York 12804 TOTAL PAGES:6 AIR DISTRIBUTION TEST SHEET TERMINAL NUMBER ROOM NUMBER TERMINAL DESIGN TEST-FPM or CFM DATE:12/22/2019 ADDRESS: 741 Upper Glen Street PAGE NUMBER:3 MJL ADTEK Enterprises, LLC P.O. Box 503, Clifton Park, NY 12065 Phone: (518) 376-9478 PROJECT NAME: Taco Bell PROJECT NUMBER:M7101 PROJECT NAME: ADDRESS: ACTUAL NA 212 0.12 0.12 0.00 1550 DAYTON 1/11 1 120 2.3 1550 1.0 TP Remarks: SYSTEM EF-1 EF-2 * No tag on fan. (1) Motor seized up. EXHAUST FAN DATA SHEET EQUIPMENT LOCATON ROOF ROOF AREA SERVICED RESTROOMS FOOD PREP DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE DIRECT DRIVE SERIAL NUMBER 95D03840 NA* SPECIFIED SPECIFIED ACTUAL EQUIPMENT MANUFACTURER GREENHECK NA* MODEL G-85-DGEX-QD NA* NS NS NA TOTAL CFM-FAN NS NS NA TOTAL CFM-OUTLET NS NS NA INLET PRESSURE NS NATOTAL STATIC PRESSURE NS MJL ADTEK Enterprises, LLC P.O. Box 503, Clifton Park, NY 12065 Phone: (518) 376-9478 BELTS MOTOR SERVICE FACTOR NS STARTER HEATER ELEMENTS NS DIRECT DRIVEMOTOR SHEAVE & NO. GROOVES FAN SHEAVE & NO. GROOVES NS TP VOLTAGE 115 AMPERAGE 3 MOTOR RPM NS MOTOR MANUFACTURER NS MOTOR HP/BHP NS NS FASCO (1) 1/8 1 NA* NA* 1550/1300/1050 1.0 NS NS 1 115 1.9 PROJECT NUMBER:M7101 12/22/2019DATE: Queensbury, New York 12804 Taco Bell 741 Upper Glen Street PAGE NUMBER: TOTAL PAGES:6 4 NS PHASE 1 DISCHARGE PRESSURE NS NS NA FAN RPM NS NS NA PROJECT NAME: ADDRESS: ACTUAL NA 2783 0.42 0.42 0.00 1326 WEG 1.0 3 210/211/210 3.1/3.2/3.1 1750 1.0 BREAKER Remarks: BELTS A28 MOTOR SHEAVE & NO. GROOVES 1VP56 x 5/8" (20% CL) FAN SHEAVE & NO. GROOVES AK60 x 3/4" MOTOR SERVICE FACTOR NS STARTER HEATER ELEMENTS NS AMPERAGE 3.47 MOTOR RPM NS PHASE 3 VOLTAGE 208 MOTOR MANUFACTURER NS MOTOR HP/BHP NS DISCHARGE PRESSURE NS FAN RPM NS TOTAL STATIC PRESSURE NS INLET PRESSURE NS TOTAL CFM-FAN NS TOTAL CFM-OUTLET NS SERIAL NUMBER 94K02500 SPECIFIED SPECIFIED ACTUAL EQUIPMENT MANUFACTURER GREENHECK MODEL CUBE-180-10G-QD3 EQUIPMENT LOCATON ROOF AREA SERVICED KITCHEN HOOD EXHAUST FAN DATA SHEET SYSTEM EF-3 DATE:12/22/2019 741 Upper Glen Street PAGE NUMBER:5 MJL ADTEK Enterprises, LLC P.O. Box 503, Clifton Park, NY 12065 Phone: (518) 376-9478 Taco Bell PROJECT NUMBER:M7101 Queensbury, New York 12804 TOTAL PAGES:6 TYPE SIZE Ak FPM CFM TEST 1 TEST 2 TEST 3 FPM CFM EF-1 1 WOMEN'S ROOM EG 8"RD 1.0 HOOD NS 127 112 NR HOOD 112 2 MEN'S ROOM EG 8"RD 1.0 HOOD NS 94 100 NR HOOD 100 TOTAL 212 EF-2 1 FOOD PREP EG 10"RD 1.0 HOOD NS 0 0 NR HOOD NA* EF-3 1 KITCHEN HOOD EG 16" X 16"1.62 NS NS 233 NR NR 144 233 2 KITCHEN HOOD EG 16" X 16"1.62 NS NS 193 NR NR 119 193 3 KITCHEN HOOD EG 16" X 16"1.62 NS NS 431 NR NR 266 431 4 KITCHEN HOOD EG 16" X 16"1.62 NS NS 449 NR NR 277 449 5 KITCHEN HOOD EG 16" X 16"1.62 NS NS 426 NR NR 263 426 6 KITCHEN HOOD EG 16" X 16"1.62 NS NS 369 NR NR 228 369 7 KITCHEN HOOD EG 16" X 16"1.62 NS NS 457 NR NR 232 457 8 KITCHEN HOOD EG 20" X 16"1.62 NS NS 225 NR NR 108 225 TOTAL 2783 Remarks: FINAL * Not running, Motor seized up. Queensbury, New York 12804 TOTAL PAGES:6 AIR DISTRIBUTION TEST SHEET TERMINAL NUMBER ROOM NUMBER TERMINAL DESIGN TEST-FPM or CFM DATE:12/22/2019 ADDRESS: 741 Upper Glen Street PAGE NUMBER:6 MJL ADTEK Enterprises, LLC P.O. Box 503, Clifton Park, NY 12065 Phone: (518) 376-9478 PROJECT NAME: Taco Bell PROJECT NUMBER:M7101