Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RC-0294-2019
TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518) 761-8201 Yry' u G" 4 Community Development - Building & Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-0294-2019 Tax Map No: 289.8-1-80 Permission is hereby granted to: Patrick Burke For property located at:18 SUNNYSIDE RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Briana Willigan Single Family-New 4001000.00 Owner Address: 18 Sunnyside RD Total Value 4001000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Patrick Burke Construction 936 Bay RD Queensbury,NY 12804 Plans&Specifications New Single-Family Dwelling w/wood FP 2,784 sf 3-car garage 1,096 sq. ft.w/unfinsihed storage room 638 sq. ft. 0.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Friday, May 29, 2020 If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Thursday, May 30, 2019 SIGNED BY:for the Town of Queensbury. Director of Building&Code Enforcement 1 f` PRINCIPLE STRUCTURE Office Use Only PERMIT APPLICATI ON Permit#: P.e 294- gal 9 Town of(tuccnsbury P 11 I ' '-ii-7; 1 Permit Fee: $ ii5lo+ G—V H E4 co -- q, 742 Bay Road,Queensbury, NY 12804 ' iIi Rec. Fee: $ n t/a i Jo s d / . IIpp PA P: 518 761 8256 www.queensbury.neY I Invoice#: 1.0 l l 1,8y S N Project Location: u T Cokatt-`41%-. CIO vh de0-41141)1N 1 i 2..`_. . = dr- aid tudt,k_ ‘f+c.__ Tax Map #: ,2*9. q- / - 'D Subdivision Name: )VA evtavr l..f v+dc,.J SPO TOWN BD.RESOLUTION 86-2013:$850 recreation fee for new dwelling units: single family, duplexes/two-family, multiplefamily. apartments,condominiums. townhouses,and/or manufactured & modular homes, but not mobile homes. This is in addition to the permit fee(s).Je s4o ,jh s14- CONTACT INFORMATION: k..)406d j' Applicant: s7 Name(s): ck tv c,/ t r')-t Mailing Address, C/S/Z:0 .1 G .s o,y Cell Phone: (,S I S' ) 2-2 2 - q3-(c,.S Land Line: ( -- ) Email: 0-,v<tke VAC& 0)rki C.i% 1 e L-0 ak Primary Owner(s): Name(s): Sr% -{1 )'1 ik t (1, 1\D:)6. Mailing Address, C/S/Z: I K &,,‘,,ny.cict_ e) asb A`i I-/ '14 Cell Phone: ( Si& ) l q I - y3)N Land Line: ( --- ) Email: Maltk4e5Nnh cssrS lo Sti-v-Q S car". Check if all work will be performed by homeowner only 9, Contractor(s): Workers' Comp documentation must be submitted with this appllcion /. (' Contractor Name(s): Q-A-6 As-t( Contractor Trade: G C Mailing Address, C/S/Z: CS0,7 DSL Cell Phone: (S1 2 2 2- 9 1i_ Land Line: ( Email: v)b ,ikk_ W7b5- ,J mA:A. ;,n List all additional contractors chi the back of this form Architect(s)/Engineer(s): Business Name: (,,)LI1./),,,,,1 -s i / (I,'Am i OtSyOr_U(1 Contact Name(s): nAox,, 1.1),\VI Ara, c Mailing Address, C/S/Z: S7D 6i C IL,, Si- CV- A.) 1( 0 5'0i Cell Phone: ( Land Line: (Sig ) 79 -L/( 5 - E m a i l: dol., d <J A\‘00.1serAd k' i k l m rt-\ ite,S i8c,Ne..CS,a t=O t5, Contact Person for Building & Code Compliance: ON\ ijal\;6.1. Cell Phone: ( Land Line: ( `IS" ) _1Cg - L S- - Email: deary Et.,./M,i,.,s- Lill,`tarei( atSif i' C'S-,cMY+ Drip,ink,etnir+iro D,,Lor o...a ..a[.L.. ...nia PROJECT INFORMATION: TYPE: Commercial Residential WORK CLASS: Single-Family Two-Family Multi-Family(#of units Townhouse Business Office Retail Hotel/Motel Industrial/Warehouse Garage(#ofcars ) Other(describe tL STRUCTURE SQUARE FOOTAGE: GARAGE SQUARE FOOTAGE: 1ST floor: it,b2 1sT floor:•SIV~70 d t y D 2"d floor: //2"d floor: fit , 6o h L4 S Y O r)-N 3rd floor: cdoOp-e- (39 S., Total square feet: Sibrei q e- Basement (habitable space): 0 J Total square feet: ,D-] ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 44f0OK 2. Proposed use of the building: _S 12 l) 3. If Commercial or Industrial, indicate the name of the business: 4. Source of Heat: Gas Oil Propane Solar Other: Fireplaces need a separate uel Burning Appliances & Chimney Application, one per appliance) 5. Are there any structures not shown on the plot plan? YES C) Explain: 6. Are there any easements on the property? YES NO 7. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? Li,,1 b. Is this a corner lot? YES NO c. Will the grade be changed as a result of the construction?YES 0 d. What is the water source? PUBLIC PRIVATE l WELL e. Is the parcel on SEWER or a PRIVATE SEPTIC system? IDS`t' ixte - Prinrinle Strurtura Parknt Revised February 2019 DECLARATION: I. I acknowiedg- that no construction shall commence priorto ssuance of a valid building permit and .or k will be completed within ... 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be Tenewed subject to fees and department approval. 3. I certify that the ,Ipplication, plans and supporting materials are -: true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conform-nce with local zoning regulations. 4. I Rcknowledge that prior to occupying the facilities proposed I, or my agents, wiP obt- m a certificAe of occupancy. 5. I understand that Ike-:re requirrd to provide an as-built survey by a licensed land surveyor of al newly constructed facilities prior t a issuance of a certificate of.coup-ncy. I have read and agree to the above: i PRINT NAME: 1 V 1(t_ SIGNATURE: --:-/---cr/4- i DATE: -SAM 0L-AU"' 1\ 40 Li•-ik. 14-Cr.-' D_ ___51b2 I 1I 7 , v Office Use Only FUEL BURNING APPLIANCE &Permit#: 4.-e2.-cidi' 2O i'l e. .k., ' 'z CHIMNEY APPLICATION Permit Fee: $ 44 Invoice#: 742 Bay Road, Queensbury, NY 12804 P:518-761-8256 queensuu y ?e Project Location: U6 St.Ar \ SicL Tax Map ID: Room of Install:6'elx.\-- C1 yr\ Planned Install Date: 11 ONE APPLICATION PER APPLIANCE** 1 . s ,- CONTACT INFORMATION:h • AA in It2f,:;°.9 10 Ta.r 4''P,sI.k, (`f IkA.ssaL k aar• Applicant: C( iNj1 T i Name(s):r l PIrnrm.. _t rt pletc a_ Mailing Address, C/S/Z:07S CoeicL}-k c-e0 61 ,ky Cell Ph.: ( —) - Land Line: ( SI S- ) 1 ctQs —22ZJ Email: Primary Owner(s): Name(s): i 4 Y\1/4\6. LiAV5 Mailing Address, C/S/Z: 13-- ,Str.."nlScett. S! Cell Ph.: (s--1 W ) -791-43114 Land Line: ( Email: L,IAe5cms @ G&i ora k\s-Alink z40(.._C_r Check if all work will be performed by homeowner only Installer/Builder: Workers' Comp documentation must be submitted with this application Contact Name(s):f i Contractor Trade: j ui,,,,1 C,4- .)0( Mailing Address, C/S/Z: 4/7S- Co,rtd,ltd a s Cell Phone: _( Land Line: _( ' ) s'i —7 PZ" O Email: brio, aR, \,-a;,, i of\ecorxs Contact Person for Building & Code Compliance: Brk Cell Ph.: ( — ) — Land Line: (S1S--- ) 742-2-2ZO Email: aria". ,c,9 v-h. sr'y ()A•Lao. Principle Structure Packet Revised February 2019 I FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: Stove Fireplace Insert Fireplace Fuel Fired Equipment (Garage Only, 18" clearance per IMC 304.3) Fireplace, factory built** Manufacturer's name: Model #: SOURCE OF HEAT: 1,, Wood Coal Pellet Gas CHIMNEY INFORMATION: Masonry (require plans to be submitted): block brick stone Flue: tile C steel size, in inches Material*: double-wall triple-wall insulated Manufacturer's name: Model #: ADDITIONAL INFORMATION: 1. Two inspections are required. A rough-in inspection, prior to installation and a final inspection, after installation. 2. Manufacturer's installation manual must be available at the time of inspection. 3. Masonry fireplaces & chimneys require plans to be submitted. 4. Twenty-four (24) hour notification is required for inspections. 5. Workers' Comp insurance information is required with this application. Declaration:Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above: PRINT NAME: 1 ) 0,-h5lC lAckL SIGNATURE: DATE: ,S709 Principle Structure Packet Revised February 2019 Office Use On!y Permit#: KL-- ®2.2,61°1TownofOye°'b ry SEPTIC DISPOSAL PERMIT APPLICATION Permit Fee: $ Invoice#: Septic Variance? Yes No 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.queensbury.net Tax Map ID#: Project Location: I vrn•k ett L Applict Name(s):Get Mailing Address, C/S/Z: cia (, 9 SCellPhone: _( ] ) " 2 2-7&y 7 Land Line: _(—®--- ) Email: pbc^c-k 0176 fit) torn- Primary Owners Name(s): ,r\ 4 Mo. LTA Mailing Address, C/S/Z: o S rl S,dt Cell Phone: _( Z13 VI Land Line: _( Email: m A G3,cAr ( 6O5s- on CicwS4itAcLA -SeIsl\ -c S ,, tor" Check if all work will be performed by homeowner only Contractor: Workers' Comp documentation must be submitted with this application Contact Name(s): 0t Af Contractor Trade: Mailing Address, C/S/Z: Cell Phone: _( Land Line: _( Email: Engineer(s): L Name(s): Eck , Yo,ra Mailing Address, C/S/Z: SO°k 66.)® 124sun Cell Phone: _( --- ) -- Land Line: _(S'7 )1 q8 Email: Oc, W\4\k‘c,a-,1 arko g O.eS`cy cr-5 r- Contact Person for Building & Code Compliance: tyke. kt\t r Cell Phone: ( Sig" ) i r,-LB Land Line: ( -- ) Email:ergo t-;or,,S cc-S t Cbrin Principle Structure Packet Revised February 2019 RESIDENCE INFORMATION: Year Built Gallons #of bedrooms: X gallons per =total daily flow per day bedroom Garbage Grinder Yes o 1980 or older 150 Installed? (circle one) 1981-1991 130 Spa or Hot Tub Yes Vo Installed? (circle one) 1992-Present 110 1410 PARCEL INFORMATION: Topography Flat Rolling Steep Slope Slope Soil Nature Sand Loam Clay Other(explain: Groundwater At what depth? Bedrock/Impervious material At what depth? Domestic Water Supply Municipal Ar Well (if well,water supply from any septic system absorption is ft.) Percolation Test Rate: 1—S— per minute per inch (test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: 0 r• es-el. fikr .tr-S Tank size 12S1) gallons (min. size 1,000 g lions, add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field with#2 stone' Total length i ri ft.; Each Trench ft. Seepage Pit with#3 stone How many: Size: Alternative System Bed or other type: Holding Tank System Total required capacity? tank size of tanks NOTES: 1. Alarm system and associated electrical work must be inspected by a Town approved electrical inspection agency; 2. We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no exceptions. 3. As-built drawings must be submitted prior to the inspection, if there has been a change to the submitted plans. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: G - crk DATE: S7 7/19 SIGNATURE: jtt DATE: 577/I f Principle Structure Packet Revised FPhruary 2019 c cREScheck Software Version 4.6.5 i Compliance Certificate D) E, C r!. li V iii rProjectPLANNO. 3533-18 Energy Code: 2015 IECC L ilijij Location: Lake George, New York P19 N (..-IL F. I Construction Type: Single-family Cg I Nrry iProjectType: New Construction d®- . E ..—__T Orientation: Unspecified 289.$_1_80 Conditioned Floor Area: 3,533 ft2 illi RC-0294-2019 Glazing Area 15% San, Briana & Mike Climate Zone: 6 (7377 HDD) 18 Sunnyside Rd Permit Date: SFD W/Wppd FP 2784 s.f., Gar. 1170 S.f.Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 18 SUNNYSIDE RD MIKE&BRI WILLIGAN Williams&Williams Designers QUEENSBURY, NY 12804 18 SUNNYSIDE RD 509 Glen St QUEENSBURY, NY 12804 Glens Falls, NY 12801 518-791-4314 518-798-4687 Compliance:Passes using UA trade-off Compliance: 0.3%Better Than Code Maximum UA: 572 Your UA: 570 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor UA'' b. Perimeter R-Value R-Value Ceiling 1: Flat Ceiling or Scissor Truss 1,449 38.0 0.0 0.030 43 Ceiling 2: Cathedral Ceiling 1,580 38.0 0.0 0.027 43 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 1,038 38.0 0.0 0.026 27 Floor 2:All-Wood Joist/Truss:Over Outside Air 24 38.0 0.0 0.026 1 Wall 1:Wood Frame, 16"o.c.538 21.0 0.0 0.057 23 Orientation: Front Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 12 0.280 3 Orientation: Front Window 2:Vinyl/Fiberglass Frame:Double Pane with Low-E 91 0.310 28 Orientation: Front Door 1: Solid 30 0.140 4 Orientation: Front Wall 2:Wood Frame, 16"o.c. 598 21.0 0.0 0.057 30 Orientation: Right side Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 12 0.280 3 Orientation: Right side Window 4:Vinyl/Fiberglass Frame:Double Pane with Low-E 54 0.310 17 Orientation: Right side Wall 3:Wood Frame, 16"o.c. 656 21.0 0.0 0.057 30 Orientation: Back 83 0.310 26 Project Title: PLAN NO. 3533-18 Report date: 07/31/18 Data filename: C:\Users\Jessi\OneDrive\Documents\REScheck\PLAN NO 3533-18-WILLIGAN- Page 1 of10 QUEENSBURY.rck Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Door 2: Glass 40 0.340 14 Orientation: Back Wall 4:Wood Frame, 16"o.c. 297 21.0 0.0 0.057 16 Orientation: Left side Door 3: Solid 20 0.140 3 Orientation: Left side Wall 5:Wood Frame, 16"o.c. 437 21.0 0.0 0.057 18 Orientation: Front Window 6:Vinyl/Fiberglass Frame:Double Pane with Low-E 116 0.310 36 Orientation: Front Wall 6:Wood Frame, 16"o.c. 638 21.0 0.0 0.057 34 Orientation: Right side Window 7:Vinyl/Fiberglass Frame:Double Pane with Low-E 12 0.280 3 Orientation: Right side Window 8:Vinyl/Fiberglass Frame:Double Pane with Low-E 36 0.310 11 Orientation: Right side Wall 7:Wood Frame, 16"o.c. 702 21.0 0.0 0.057 34 Orientation: Back Window 9:Vinyl/Fiberglass Frame:Double Pane with Low-E 111 0.310 34 Orientation: Back Wall 8:Wood Frame, 16"o.c. 284 21.0 0.0 0.057 14 Orientation: Left side Window 10:Vinyl/Fiberglass Frame:Double Pane with Low-E 36 0.310 11 Orientation: Left side Basement Wall 1: Solid Concrete or Masonry 462 0.0 21.0 0.035 16 Orientation: Front Wall height: 9.0' Depth below grade: 8.0' Insulation depth: 9.0' Basement Wall 2: Solid Concrete or Masonry 438 0.0 21.0 0.035 15 Orientation: Right side Wall height: 9.0' Depth below grade: 8.0' Insulation depth: 9.0' Basement Wall 3: Solid Concrete or Masonry 563 0.0 21.0 0.035 19 Orientation: Back Wall height: 9.0' Depth below grade: 8.0' Insulation depth: 9.0' Window 11:Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.290 5 Orientation: Back Basement Wall 4: Solid Concrete or Masonry 256 0.0 21.0 0.035 9 Orientation: Left side Wall height: 9.0' Depth below grade: 8.0' Insulation depth: 9.0' Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Jessica Chenier Bulman 07/31/18 Name-Title nature Date 1 ' Project 11, Title: PLAN NO. 3533-18jiplii fl 1 j port date: 07/31/181 Data filename: C:\UsersUessi\OneDrive\Documents\REScheck\PLAN NO 35 -! • GAN- Page 2 of10 QUEENSBURY.rck 0 REScheck Software VersionChecklist 4.6.5 si Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified Pre4nspection/Plan Review Value Value Complies? Comments/Assumptions Req.ID 103.1, Construction drawings and EComplies 103.2 documentation demonstrate DDoes Not PR1]1 energy code compliance for the J4 building envelope.Thermal DNot Observable envelope represented on Not Applicable construction documents. 103.1, Construction drawings and Complies 103.2, documentation demonstrate Does Not 403.7 energy code compliance for PR3]1 lighting and mechanical systems. Not Observable Systems serving multiple ElNot Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr Does Not PR2)2 on loads calculated per ACCA Cooling: Cooling: Not ObservableManualJorothermethodsBtu/hr Btu/hr approved by the code official. ENot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PLAN NO. 3533-18 Report date: 07/31/18 Data filename: C:\Users\Jessi\OneDrive\Documents\REScheck\PLAN NO 3533-18-WILLIGAN- Page 3 of10 QUEENSBURY.rck Section Plans Verified Field Verified Foundation Inspection Value Value Complies? Comments/Assumptions Req.ID 402.1.1 Conditioned basement wall R- R- Complies See the Envelope Assemblies F04]1 insulation R-value.Where interior R_ R- Does Not table for values. insulation is used,verification Not Observable may need to occur during Insulation Inspection. Not Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall Complies F05)1 insulation installed per Does Not manufacturer's instructions. Not Observable Not Applicable 402.2.9 Conditioned basement wall ft ft Complies See the Envelope Assemblies F06]1 insulation depth of burial or Does Not table for values. distance from top of wall.Not Observable Not Applicable 303.2.1 A protective covering is installed Complies F011]2 to protect exposed exterior Does Not insulation and extends a minimum of 6 in. below grade. Not Observable Not Applicable 403.9 I Snow-and ice-melting system Complies F012]2 controls installed. Does Not 2J Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PLAN NO. 3533-18 Report date: 07/31/18 Data filename: C:\Users\Jessi\OneDrive\Documents\REScheck\PLAN NO 3533-18-WILLIGAN- Page 4 of10 QUEENSBURY.rck Section Plans Verified Field Verified Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions Req.ID 402.1.1, Door U-factor. U- U- DComplies See the Envelope Assemblies 402.3.4 Does Not table for values. FR1]1 Not Observable ONot Applicable 402.1.1, Glazing U-factor(area-weighted U- U- DComplies See the Envelope Assemblies 402.3.1, average). Does Not table for values. 402.3.3, 402.5 Not Observable FR2]1 ONot Applicable 303.1.3 U-factors of fenestration products DComplies FR4]1 are determined in accordance Does Not with the NFRC test procedure or taken from the default table.ONot Observable ONot Applicable 402.4.1.1 Air barrier and thermal barrier Complies FR23]1 installed per manufacturer's Does Not instructions. Not Observable ONot Applicable 402.4.3 Fenestration that is not site built DComplies FR20]1 is listed and labeled as meeting Does Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ONot Observable 400 that do not exceed code ONot Applicable limits. 402.4.5 IC-rated recessed lighting fixtures DComplies FR16]2 sealed at housing/interior finish Does Not and labeled to indicate 52.0 cfm leakage at 75 Pa. ONot Observable ONot Applicable 403.3.1 Supply and return ducts in attics ! DComplies FR12]1 insulated >= R-8 where duct is Does Not 3 inches in diameter and >= R-6 where<3 inches.Supply and Not Observable return ducts in other portions of ENot Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.5 Building cavities are not used as DComplies FR15]3 ducts or plenums. DDoes Not ONot Observable ONot Applicable 403.4 HVAC piping conveying fluids R- R- DComplies FR17]2 above 105°F or chilled fluids Does Not below 55°F are insulated to>_R ONot Observable3. Not Applicable 403.4.1 Protection of insulation on HVAC DComplies FR24]1 piping.Does Not ONot Observable DNot Applicable 403.5.3 Hot water pipes are insulated to R- R- DComplies FR18]2 >_R-3. Does Not Not Observable ONot Applicable 403.6 Automatic or gravity dampers are DComplies FR19]2 installed on all outdoor air Does Not intakes and exhausts. Not Observable ONot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PLAN NO. 3533-18 Report date: 07/31/18 Data filename: C:\Users\Jessi\OneDrive\Documents\REScheck\PLAN NO 3533-18-WILLIGAN- Page 5 of10 QUEENSBURY.rck Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PLAN NO. 3533-18 Report date: 07/31/18 Data filename: C:\Users\Jessi\OneDrive\Documents\REScheck\PLAN NO 3533-18-WILLIGAN- Page 6 of10 QUEENSBURY.rck Section Plans Verified Field VerifiedinsulationInspection Value Value Complies? Comments/Assumptions Req.1D 303.1 All installed insulation is labeled Complies IN13]2 or the installed R-values Does Not provided. Not Observable Not Applicable 402.1.1, Floor insulation R-value. R- R- Complies See the Envelope Assemblies 402.2.6 Wood Wood Does Not table for values. IN1]i Steel Steel Not Observable w1' Not Applicable 303.2, Floor insulation installed per Complies 402.2.7 manufacturer's instructions and Does Not IN2]i in substantial contact with the underside of the subfloor,or floor Not Observable framing cavity insulation is in Not Applicable contact with the top side of sheathing,or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing !; members. 402.1.1, Wall insulation R-value. If this is a R- R- Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1 of the Wood Wood Does Not table for values. 402.2.6 wall insulation on the wall Mass Mass Not ObservableIN3]1 exterior,the exterior insulation requirement applies(FR10).El Steel Steel Not Applicable 303.2 Wall insulation is installed per Complies IN4]1 manufacturer's instructions. Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PLAN NO. 3533-18 Report date: 07/31/18 Data filename: C:\Users\Jessi\OneDrive\Documents\REScheck\PLAN NO 3533-18-WILLIGAN- Page 7 of10 QUEENSBURY.rck Section Plans Verified Field VerifiedFinalInspectionProvisions Value Value Complies? Comments/Assumptions Req.ID 402.1.1, Ceiling insulation R-value. R- R- Complies See the Envelope Assemblies 402.2.1, Wood Wood Does Not table for values. 402.2.2, Steel Steel Not Observable 402.2.E[ FI111 Not Applicable 303.1.1.1, Ceiling insulation installed per Complies 303.2 manufacturer's instructions. EDoes Not FI2]1 Blown insulation marked every 300 ft2. Not Observable Not Applicable 402.2.3 Vented attics with air permeable Complies FI22]2 insulation include baffle adjacent Does Not to soffit and eave vents that extends over insulation. Not Observable Not Applicable 402.2.4 Attic access hatch and door R- R- Complies FI3]1 insulation >_R-value of the Does Not adjacent assembly.Not Observable Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50= Complies F117]1 ach in Climate Zones 1-2, and Does Not 3 ach in Climate Zones 3-8. Not Observable Not Applicable 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 Complies FI4]1 cfm/100 ft2 across the system or ft2 ft2 Does Not 3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in Not Observable tests,verification may need to Not Applicable occur during Framing Inspection. 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 Complies F127]1 determine air leakage with ft2 ft2 Does Not either: Rough-in test:Total leakage measured with a Not Observable pressure differential of 0.1 inch Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated Complies F124]1 by manufacturer at<=2%of Does Not design air flow. Not Observable Not Applicable 403.1.1 Programmable thermostats Complies FI912 installed for control of primary Does Not heating and cooling systems and initially set by manufacturer to Not Observable code specifications. Not Applicable 403.1.2 Heat pump thermostat installed Complies F110]2 on heat pumps. Does Not Not Observable Not Applicable 403.5.1 Circulating service hot water Complies FI11]2 systems have automatic or Does Not accessible manual controls. Not Observable Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PLAN NO, 3533-18 Report date: 07/31/18 Data filename: C:\Users\jessi\OneDrive\Documents\REScheck\PLAN NO 3533-18-WILLIGAN- Page 8 of10 QUEENSBURY.rck Section Plans Verified Field VerifiedFinalInspectionProvisions Value Value Complies? Comments/Assumptions Req.ID 403.6.1 All mechanical ventilation system OComplies FI25]2 fans not part of tested and listed DDoes Not HVAC equipment meet efficacy and air flow limits. Not Observable Not Applicable 403.2 Hot water boilers supplying heat OComplies FI26]2 through one-or two-pipe heating Does Not systems have outdoor setback control to lower boiler water DNot Observable temperature based on outdoor DNot Applicable temperature. 403.5.1.1 Heated water circulation systems OComplies F128]2 have a circulation pump.The Does Not system return pipe is a dedicated return pipe or a cold water supply, Not Observable pipe.Gravity and thermos- DNot Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems OComplies F129]2 comply with IEEE 515.1 or UL Does Not 515.Controls automatically adjust the energy input to the Not Observable heat tracing to maintain the Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that OComplies FI30]2 have recirculation pumps that Does Not pump water from a heated water supply pipe back to the heated Not Observable water source through a cold DNot Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units Complies FI31]2 tested in accordance with CSA EDoes Not B55.1. Potable water-side pressure loss of drain water heat ! ENot Observable recovery units<3 psi for Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent OComplies FI6]1 fixtures or 75%of permanent Does Not fixtures have high efficacy lamps. Does not apply to low-voltage Not Observable lighting. Not Applicable 404.1.1 Fuel gas lighting systems have OComplies FI23]3 no continuous pilot light. ElDoes Not ONot Observable Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PLAN NO. 3533-18 Report date: 07/31/18 Data filename: C:\Users\Jessi\OneDrive\Documents\REScheck\PLAN NO 3533-18-WILLIGAN- Page 9 of10 QUEENSBURY.rck Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions Req.ID 401.3 Compliance certificate posted. Complies FI7]2 DDoes Not Not Observable DNot Applicable 303.3 Manufacturer manuals for DComplies FI18]3 mechanical and water heating Does Not systems have been provided.Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PLAN NO. 3533-18 Report date: 07/31/18 Data filename: C:\Users\Jessi\OneDrive\Documents\REScheck\PLAN NO 3533-18-WILLIGAN- Page 10 of10 QUEENSBURY.rck 4 20El( 15 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 21.00 Floor 38.00 Ceiling/ Roof 38.00 Ductwork(unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.31 0.29 Door 0.34 0.23 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments f; 1:,ta.=;•• Z; tVE31, 11,T3k, C011eFef: 4 IKsv/AC 2.3(Reif moir-Ag z-41,04,f,e,.:4se; ap-morl t)kto-,edgi.t6nT, A3L-YLPs1,1 1,k55. L.,It':::114 IL:7f Ma:61 7:410';) IFAATAER 7..40 rns sff 1Y,.4 ',',7..,:im Tzp,q:-..Y.' 1 1 A ir, :•.-;.,?‘ 6A,T:, La-nifd-o,D-C wyr,-,-:Jercg .IE:, 2r .,,--T, Zir.'.E.,-IT '!.--:Q.'72.17...-C.NF'T,i2ZirP,:. :,-5-:,:.E.:T5'-'-.' i ranef:c lilIzi L.,x,..,lf ic[Efsfa.i..,,_-.1:-..-7•Run,:,,Tal-,ffLair-z-7 .I'Nf.a3s11,-,',5--fls; Grilb:---3' Cifj,!•?:17. c.- i y, 5.=,r.r; ,--) 6, 7f.,1 71:-',v,z;:r 1...-c--,-• '-' 11a.':;:-::,2, © E.--5.f'X: © f:: 1,77--tT1' 7';' f:- 1227r132 ac5.S4'.fl,,Cfa '..',g_A i f.,,,,...,,-. 15,t-:r--::::s•gii.-g-1 Lq:gy,'E,riT11(-7-),cl'aw:1 ,,i,:,-- 1 V.--±c5:6C, Ec.?.,- ifiW'jr,..oi 1,_•.,1:,,,e75.r ,-,...„; 155 2, 6..::.,7., i.,,,,,:,a.1) 7Z f,'':ffilli'i'2.-W-':Ltillidk.:g.:.(ti :,,h7,11..1.3,'Z''..1),1611',/f.ffj:E%:.i':";.1'.7 :,'.1:7,,n9';t:7',_,1'.' 7ii;,:021) fAr;TIC;11'7 1:7117 f,',171,757L'iatl'Ii:::21i6-;e ',-•:''',:';'1/77:1':"•-'71Trt Cco,3.)4,11-1-1'q Ccsq:IiIng t7,.n1 43,718 4.,53 Zs':sr5-5, JJLL 1,1,d TT, icigh 3anD 5,.0© 0.‘ngIC) 7/15 5i',7.12'S 9 3,72-fiLiTa 1,.6.3)2,112 5rk-ALfilrA,Oggfigi 1:s2c.s:TT1 7.Al!ll CC,a,z.)-)LIN LcoAd t•-• tArlrirgi'CV 711'7-a cv7,001700;7 V! 1,?)*(01-,firr VariliferP,kf,TMF 1,q !LT facgmoo.Torior2 /,'Iarfolepee 5 7.7rdgfeam pot-flgmed T,773fi.D.11,10.V.:TiL757',f,3 Ero)CP,Q5. Tim I-Rob-,-..g..7[Tpc-zil T•Jx,f,§ ftTj71 LY7i@ diteag,T teqUiga:EFCCItISite Tt3r(-17,-f- Icict CoaIrg iHseenc% 1,52 J 112 S"gAS:?! 71, ers'a Raztt-dmAii(1-: 0&-c.-24116.icsant)-Aikomrd); A ECaKcisge",.4; DAF,511.1,inceT Xivik301::(J..,1,ilLtt,ilrel;fit,:i111%1419! 7,23 9 frI) 5.Ed jP,(ore DfD-1-1,Esi.VaVe, att' fsuitilvt'cg ef!,7.3 4ifkt 2-3 F73IT kflati) rM E, Tf.tiza, 7/C 1-AtTVI Gnfin 11)(H 31%, I3F Wit) 7 Ctt•Stlaq ilE1111Q•j [1:)iTfi-71:@;711 E li-r3f[.TA LNItir:t rajf ii4111111'S 810,J;,-;! TLNI Mc- tisg,sr3 verro';, tilrti.t:), Atr CLtrAtIficiFtSfl 0 s:) 54 4 77.521 IT 4772':•71 tti cOaRS,17:Fm (2,:x OK UNDER,Cia:K) EluiPFZ•f"Vis CD)OZTO.CFF ll PiN.wsfore(s.S 1,i,',7SZ-EuTAirrn.SK6S'Lf iNg,RIGT AI? rrie&P, Tua,Gtic-Pd VOr 1-f l'ASWer L'Apc,6',C11.L.4 fpnr,-,3 P-)capacky ia) 17,F Tcd•g: CTilk7.11;Intrz 0-07 SS',7475).41 rarYlai:e FF5P8 supfMcm.:erta:., C45;j1W cAriltrp224.( Fan SLiatTsZT 7/20 • rittiLi ''- •A Pbw ti s - j(3`S 1 y e t Sno31$ i and So ec ni:ca L fabr rotr HR Y or ERV S,, 't '+;' 'di si" by 7 p yaj,;ry — 9, i- ,5 g,nt C a best HRVf`r Vic?° 7 ''' 4 ae 5:;p.I,.org E• aim fir erm o1r c_ h to Ul ,eur the bigr A y,:ur& ' 7,,,,, ztr,:14 z t 5,. 4 a 1,P m ` 3 8 5 ro w ,n 'P '. '' "'5"i` 3 aa* Option,.s 'i. your Residential„,....,",,la^s: unit by ,. t, ,<.s ` €d / r) 7 r .. 3.'".:+ .r$4.,°..td r Step 1 Step`Y j 2400scg (I.s'IT)with 9' r celiM I aE/3qr IT &Cub ic Volume x„5)/60 Ei 21av,' $9 E' r 4 5r7 5.:7"w Pd t?.0 `das'te3<RE in vt11 cases°osai sod al other codes r iauet'ementz must tie Wowed Option 2:Size you 8esIde n Ia-I unit using ASHPAE 62,2(Mir9r¢'um requ r er t ent) st a s9e d i`i om Air Requ9 eft' eo?s(C V:/4'e'z J•o , I P, ASPR45.2.2TABLE cis j I _ ,_J__I 2 ate e.....,_ l __ i 1 bi 12 ___ gi 135 i re:L,,, -,:lon,,7n_k___.:3-,:c„.,)___. t.L_LI1 ,-,„,,,._--..,,k.), I.I L.A.) h._, ,,-, J,:-: _L___g____!, 502,0l`2 ,r -1.... I <.._. i'&5 y°P? 18._ .. e,_ S, V y T 95.. a—zI.J i ° ail cab'es>oc `:and ai;other codes requirements must be to!io ed Size your Co nws. i uidt. -P o e it'recorm nded a m echotnico/engineer viwav5 be cor,suited. IT„ o,-- plc , 'T es, :, ( f F ;di:7 4_ U n 'd.J: nis ic,P5Let ,dr o sue 1 x m,. - ... 4 o..-,.,..._,.,._......, tm 4 i orym 425 35_ 1 m _v 1'! 1 ^'G43 W i 10 1 IEAR a.®,.,.r..r - - _.fl,..»,.-a._ ,..,.. t'7E' 7 1,"Ii.U P" egA y 3 0 Do B: {i l'. q stw N'_ - _... a._, 5.., PetShops n,.......»..s. t e...,....... ,m....„s....-_..,a..._..._„... .._.. Ban-1 } fie.: dr— — y ^n2„,,0 d ,,.. ,,, , g t Hemh 4 i} m. - ,....,,..i'``,..>..Q- -._v.,..a p....--_.>., a.-.. ...,,gym FP,' P Z 1 e .,._ 1. a a Testing Company: Name:LoCascio Energy Solutions Address:20 Ogden Rd. Queensbury , NEW YORK 12804 Phone: 5188573144 Technician: Name:Anthony LoCascio Credentials:HERS Rater#4242961 Email:tony@locascioenergysolutions.com Building Information: Project ID:18 Sunnyside Address:18 Sunnyside Rd Queensbury, NY 12804 Geo-Tag Data:Latitude: 43.373508 Longitude: -73.646405 Timestamp: 2020-04-21 15:52:43 Customer Information: Name:Patrick Burke Construction Address:936 Bay Rd Queensburry, NY 12804 Measured Leakage:1,894.9 CFM50 Test ID:18 Sunnyside Purpose of Test:50 Pa Env. Leakage Measured ACH50:2.92 Effective Leakage Area: 104.2 in² Building Volume:38,911.0 ft³Enclosure Surface Area: 4,386.0 ft² Flow Coefficient (C):149.0 Exponent (n): 0.650 (assumed) Test Standard:RESNET 380 One-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 63 °F Altitude: 388.0 ft Outdoor Temp: 42 °F Time Average Period: 10 seconds Test Date and Time:2020-04-21 16:32:44 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -1.2 50.0 -50.7 -49.5 -119.1 1,954.6 Ring A Test Equipment: Flow Device:Model 3 110V Fan Serial #: 3173 Custom Calibration Date: 2020-02-10 Pressure Gauge:DG1000 Serial #: 3173 Calibration Date: 2019-02-18 Deviations from Standard: None Comments: Envelope Leakage Test (Page 2) Report generated by TEC Auto Test version 1.6.3 (2), © 2019 by The Energy Conservatory, Inc. f i 1 1 i 1 0 i ill ( fri- {, IS -11"te-Ifirlilltit_ a 2 6'-/R-c...- 1;(2.d\z - /..oq t_C 21_—' ___I---- 1 LI i I --:. Pr) Fell i , i i_ L 33 _ t 1 - cR, . .-"c3_ I LT ll i r-7 H 1 . 1.2 2 0a3 6q 00' 1 . 0 1$,..LI .1 r7 - f 1 1 t.' t I 4. 0.‘ i 414..6.d.,, a 1----- i I I I vidokiks.......r.,„,......, t I. s.,I 14tt i 4.,41/4 \k:-, 1• v A, • 11 bitillrwAk 1 i ii ry4 f., .Noih.0 14,1',:‘,.4d M $aill i4 1 G z- N lN f1/ 6 4°' '' - 6e\ 4 LEACH FIELD: 6 4 RUNS OF 46' EACH EXISTING TOTAL LENGTH: 1 8 4' ELL MINIMUM 20' FROM HOUSE 1 0' SEPTIC SYSTEM SETBACK 50% EXPANSION SHADED)I' DISTRIBUTION BOX 1 250 GALLON SEPTIC TANK \ 0 MINIMUM 1 0' FROM HOUSE 0 7 .N a * NN 66 7aN, ,s' a% 4, 4/ titi.z 111 AREA l'', 1. o mmc Z9 1 1 q,20 1 .q SOFT it ,° : r- N r, 4. 1 1 ACRES HOME TO BE REMOVEDLk3EC192019OF-".__, O JQUEENSBURyUDING& CODES J 6 O EXIS G