BINS-007974-2018 11142018INSPECTION WORKSHEET (BINS-007974-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-000173-2017Case Module:Permit
Inspection Date:Wed Nov 14, 2018Inspection Status:Partial Pass
Inspector:Charles DyerInspection Type:Building Foundation
Job Address:42 GRAND VIEW DRParcel Number:289.16-1-14
Queensbury, NY 12804
Contact TypeCompany NameName
ArchitectDonovan, Andrew
ContractorMichaels, J.
Primary OwnerMichaels, J.
ApplicantMichaels, J.
Granted PermissionMichaels, J.
Checklist ItemPassedComments
Building Inspector NotesNO
FootingsYESWith 2 rows # 4 continuous, wet sticking with # 6 verticals
PiersNO
Monolithic SlabNO
Reinforcement in PlaceYES
Foundation / WallpourYES11/14/18
Reinforcement in PlaceYES11/14/18
Nov 14, 2018Page (1)
INSPECTION WORKSHEET (BINS-007974-2018)
Checklist ItemPassedComments
Footing Dowels or Keyway in placeYES
Foundation DampproofingNO
Foundation WaterproofingNO
Footing Drain Daylight or SumpNO
Footing Drain Stone - 12 inch widthNO
Footing Drain Stone - 6 inches above footingNO
Footing Drain stone - 6 mil polyNO
Backfill ApprovalNO
Plumbing Under SlabNO
PVC / Cast / CopperNO
Foundation Insulation Interior / ExteriorNO
Rough Grade 6 inch drop within 10 ft.NO
Poly Under SlabNO
Dyer, Charles (Inspector)