ResCheck 289.18-1-35.2 RC-000115-2017 Generated by REScheck-Web E Wild, Ryan 14 Blackberry Ln Compliance Certif SFD w/wood FP 2502 s.f., Gar. 642 s.f. Project PLAN NO. 2502-17-LOT 2 BLACKBERRY LN Energy Code: 2015 IECC Location: Warren County, New York D fL (gyp 0 Construction Type: Single-family E C J' Project Type: New Construction D Orientation: Bldg. faces 315 deg. from North MAR 2 3 Conditioned Floor Area: 2,502 ft2 2 1/ Glazing Area 23% Climate Zone: 6 (8499 HDD) TOM BUILDING Permit Date: CODES Permit Number: Construction Site: Owner/Agent: Designer/Contractor: LOT 2 BLACKBERRY LANE CREATIVE SPACES WILLIAMS&WILLIAMS DESIGNERS QUEENSBURY, New York 12804 509 GLEN STREET GLENS FALLS, New York 12801 518-798-4687 W ILLIAMSAND WILLIAMSDESIGNERS. COM Compliance: Passes using UA trade-off Compliance: 0.6%Better Than Code Maximum ILA: 504 Your UA: 501 The%Better or worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a mmimummode home. Envelope Assemblies Gross Area Cavity Cont. Per meter Ceiling: Cathedral 1,846 38.0 10.0 0.021 39 Ceiling: Flat or Scissor Truss 697 49.0 0.0 0.026 18 Floor: All-Wood Joistfrruss Over Uncond. Space 624 38.0 0.0 0.026 16 Floor: Heated Slab-On-Grade 76 10.0 0.684 52 Insulation depth: 4.0' Wall: Wood Frame, 16in.D.C. 573 21.0 0.0 0.057 28 Orientation: Front Window: Wood Frame, 2 Pane w/Low-E 49 0.300 15 Orientation: Front Door: Solid 20 0.140 3 Orientation: Front Door: Glass 20 0.320 6 Orientation: Front Wall: Wood Frame, 16in.D.C. 736 21.0 0.0 0.057 32 Orientation: Right side Window: Wood Frame, 2 Pane w/Low-E 86 0.300 26 Orientation: Right side Window: Wood Frame, 2 Pane w/Low-E 43 0.290 12 Orientation: Right side Project Title: PLAN NO. 2502-17-LOT 2 BLACKBERRY LN Report date: 03/21/17 Data filename: Page 1 of 11 Gross Area Cavity Cont. Assembly or U-Factor UA Door:Glass 37 0.320 12 Orientation: Right side Wall:Wood Frame, 16in.o.c. 489 21.0 0.0 0.057 22 Orientation: Back Window:Wood Frame, 2 Pane w/Low-E 103 0.300 31 Orientation: Back Wall:Wood Frame, 16in.o.c. 349 21.0 0.0 0.057 19 Orientation: Left side Window:Wood Frame, 2 Pane w/Low-E 13 0.300 4 Orientation: Left side Wall:Wood Frame, 16in.o.c. 246 21.0 0.0 0.057 12 Orientation: Right side Window:Wood Frame, 2 Pane w/Low-E 15 0.300 5 Orientation: Right side Window:Wood Frame, 2 Pane w/Low-E 18 0.270 5 Orientation: Right side Wall:Wood Frame, 16in.o.c. 275 21.0 0.0 0.057 12 Orientation: Left side Window:Wood Frame,2 Pane w/Low-E 60 0.300 18 Orientation: Left side Basement:Solid Concrete or Masonry 412 0.0 15.0 0.044 18 Orientation: Front Wall height:9.0' Depth below grade:8.0' Insulation depth:9.0' Basement: Solid Concrete or Masonry 167 0.0 15.0 0.044 7 Orientation: Right side Wall height: 9.0' Depth below grade:8.0' Insulation depth: 9.0' Basement: Solid Concrete or Masonry 209 21.0 0.0 0.056 8 Orientation: Right side Wall height: 9.0' Depth below grade:0.0' Insulation depth:9.0' Window:Wood Frame,2 Pane w/Low-E 60 0.300 18 Orientation: Right side Basement:Wood Frame 35 21.0 0.0 0.060 2 Orientation: Right side Wall height:9.0' Depth below grade: 0.0' Insulation depth:9.0' Basement:Wood Frame 382 21.0 0.0 0.060 17 Orientation: Back Wall height:9.0' Depth below grade: 0.0' Insulation depth:9.0' Window:Wood Frame, 2 Pane w/Low-E 60 0.300 18 Orientation: Back Door:Glass 40 0.320 13 Orientation: Back Basement:Solid Concrete or Masonry 35 21.0 0.0 0.056 2 Orientation: Left side Wall height:9.0' Depth below grade: 0.0' Insulation depth:9.0' Basement: Solid Concrete or Masonry 100 21.0 0.0 0.042 4 Orientation: Left side Wall height: 9.0' Depth below grade: 8.0' Insulation depth:9.0' Project Title: PLAN NO. 2502-17-LOT 2 BLACKBERRY LN Report date: 03/21/17 Data filename: Page 2 ofll Gross Area Cavity Cont. Assembly or U-Factor UA Basement: Solid Concrete or Masonry 79 21.0 0.0 0.050 4 Orientation: Unspecified Wall height:9.0' Depth below grade: 5.0' Insulation depth:9.0' Basement:Solid Concrete or Masonry 71 0.0 15.0 0.044 3 Orientation: Left side Wall height: 9.0' Depth below grade: 8.0' Insulation depth: 9.0' Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 5.5.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Jessica Chenier Bulman 3essica Chewt FdwRH 03/21/17 Name-Title Signature � NEIN Date 54P �pKEII Jr , �P S r r- I P/ � (23117 Project Title: PLAN NO. 2502-17-LOT 2 BLACKBERRY LN Report date: 03/21/17 Data filename: Page 3 of 11 REScheck Software Version 5.5.0 C�(J Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, !Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR111 energy code compliance for the .� building envelope.Thermal []Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 -energy code compliance for [PR3)1 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, !Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr— Btu/hr ❑Does Not [PR212 on loads calculated per ACCA Cooling: Cooling: ❑Not Observable Manual J or other methods . Btu/hr_ Btu/hr_ ❑Not Applicable approved by the code official. Additional Comments/Assumptions: 1 1 High Impact(Tier 1) 12 1 Medium Impact(Tier 2) 1 3 1 Low Impact(Tier 3) Project Title: PLAN NO. 2502-17-LOT 2 BLACKBERRY LN Reportdate: 03/21/17 Data filename: Page 4 of 11 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Re .ID 402.1.2 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies [F0111 ❑ Unheated ❑ Unheated ❑Does Not table for values. 0 ❑ Heated ❑ Heated []Not Observable ❑Not Applicable 402.1.2 Slab edge insulation _ft - _ft ❑Complies ,See the Envelope Assemblies [F0311 depth/length. j ❑Does Not ,'table for values. 0 ❑Not Observable []Not Applicable 402.1.1 Conditioned basement wall R- R-_ ❑Complies See the Envelope Assemblies [F0411 insulation R-value.Where interiorR- R- ❑Does Not ;table for values. J insulation is used,verification []Not Observable may need to occur during Insulation Inspection. Not ❑Not Applicable j required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall [ Complies [F0511 insulation installed per []Does Not U manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall _ft _ft ❑Complies See the Envelope Assemblies [F06)1 insulation depth of burial or ❑Does Not (table for values. 4 distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO 1112 to protect exposed exterior ❑Does Not insulation and extends a ❑Not Observable minimum of 6 in. below grade. ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [F012)2 controls installed. ❑Does Not ❑Nat Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: PLAN NO. 2502-17-LOT 2 BLACKBERRY LN Report date: 03/21/17 Data filename: Page 5 of 11 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Re .ID 402.1.1, (Door U-factor. U-_ U-_ ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR111 ❑Not Observable I' ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U-_ U-_ ❑Complies !See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, []Not402.3.6, Not Observable 402.5 ❑Not Applicable [FR2]1 M, 303.13 U-factors of fenestration products ❑Complies [FR411 are determined in accordance i❑Does Not V, with the NFRC test procedure or ❑Not Observable taken from the default table. UNot Applicable 402.4.1.1 Air barrier and thermal barrier I❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. j❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ;❑Complies [FR20]1 is listed and labeled as meeting ;❑Does Not j AAMA/WDMA/CSA 101/1.S.2/A440 j❑No[Observable or has infiltration rates per NFRC 400 that do not exceed code ;❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures J❑Complies [FR16]2 sealed at housing/interior finish '❑Does Not and labeled to indicate <_2.0 cfm ![]Not Observable leakage at 75 Pa. ❑Not Applicable 403.2.1 Supply and return ducts in attics ;❑Complies [FR1211 insulated >= R-8 where duct is t❑Does Not >= 3 inches in diameter and >_ ❑Not Observable R-6 where< 3 inches.Supply and return ducts in other portions of j❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for<3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observabie ❑Not Applicable j 403.4 HVAC piping conveying fluids R- R-_ ❑Complies [FR17]2 above 105 2F or chilled fluids ❑Does Not 3elow 55 QF are insulated to aR- : ❑Not Observable . ❑Not Applicable 403.4.1 Protection of Insulation on HVAC ❑Complies (FR2411 piping. ❑Does Not ❑Not Observable ❑Not Applicable ! 403.5.3 Hot water pipes are insulated to R- R-_ ❑Complies IFR1812 IaR-3. ❑Does Not ll� ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies IFR1912 :installed on all outdoor air ❑Does Not :intakes and exhausts. ❑Not Observable , ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: PLAN NO. 2502-17-LOT 2 BLACKBERRY LN Report date: 03/21/17 Data filename: Page 6 of 11 Additional Comments/Assumptions: ---------- 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 37) Project Title: PLAN NO. 2502-17-LOT 2 BLACKBERRY LN Report date: 03/21/17 Data filename: Page 7 of 11 Section Plans Verified Field Verified # Insulation inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled '..❑Complies [IN13]2 or the installed R-values ❑Does Not ,� provided. ;❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope assemblies 402.2,6 ❑ Wood El Wood ❑Does Not table for values. [IN111 ❑ Steel -❑ Steel ❑Not Observable 0 ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions and ❑Does Not [IN211 in substantial contact with the ❑No[Observable _ underside of the subfloor, or floor framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value.If this is a R- R-_ ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not 'table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN311 exterior,the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per []Complies [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: ------------- 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: PLAN NO. 2502-17-LOT 2 BLACKBERRY LN Report date: 03/21/17 Data filename: Page 8 of 11 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re .ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, E] Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel [-]Not Observable F1111 6 [ ❑Not Applicable FIl] 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI211 Blown insulation marked every ❑Not Observable 300 ft2. ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that ❑Not Observable ,extends over insulation. []Not Applicable 402.2.4 Attic access hatch and door R- R-_ ❑Complies [FI311 insulation>R-value of the ❑Does Not .adjacent assembly. []Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa.<=5 ACH 50=_ ACH 50=_ ❑Complies [FI1711 ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. []Not Observable []Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 '❑Complies [1`I411 cfm/100 ft2 across the system or ft2 ftz ❑Does Not <=3 cfm/100 ft2 without air ❑Nat Observable handler @ 25 Pa. For rough-in tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F12711 determine air leakage with ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test.Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. _ 403.3.2.1 Air handler leakage designated ❑Complies [FI2411 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable , 403.1.1 Programmable thermostats ❑Complies [F[9]2 installed for control of primary ❑Does Not heating and cooling systems and ;initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [F110]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [Flll]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) r Medium Impact(Tier 2) 13 JLow Impact(Tier 3) Project Title: PLAN NO. 2502-17-LOT 2 BLACKBERRY LN Report date: 03/21/17 Data filename: Page 9 of 11 Section Plans Verified Field Verif led # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system ❑Complies [F125]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [FI2617 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [FI28]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated ❑Not Observable return pipe or a cold water supply pipe.Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system - pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [FI29]2 comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water ❑Not Observable supply pipe back to the heated water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. 403.5.4 Drain water heat recovery units ❑Complies [F131]' tested in accordance with CSA ❑Does Not - B55.1.Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers.Potable water- side pressure loss of drain water heat recovery units<2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent [ Complies [FI611 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [FI2313 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable j 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: PLAN NO. 2502-17-LOT 2 BLACKBERRY LN Report date: 03/21/17 Data filename: Page 10 of 11 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req. 401.3 Compliance certificate posted. ❑Complies [1`I7]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating []Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: PLAN NO. 2502-17-LOT 2 BLACKBERRY LN Report date: 03/21/17 Data filename: Page 11 of 11 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 38.00 Ceiling / Roof 48.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.30 Door 0.32 Heating&Cooling Equipment Efficiency Heating System• Cooling System: Water Heater: Name• Date: Comments