Loading...
ResCheck REScheck Software Version 4.6.5 Compliance Certificate Project PLAN NO 1587-19 Energy Code: 2015 IECC Location: Glens Falls, New York Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 1,587 ft2 Glazing Area 9% Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: LOT 12 PGRDM LLC Jessica Chenier Bulman SHALLOW CREEK ROAD 10 KNIGHT STREET Williams&Williams Designers QUEENSBURY, NY 12804 GLENS FALLS, NY 12801 509 Glen St 518-415-2486 Glens Falls, NY 12801 518-798-4687 ompliance: Passes using UA trade-off Compliance: 1.9%Better Than Code Maximum UA: 268 Your UA: 263 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly °r R-Value R-Value U-Factor UA Perimeter Ceiling 1: Raised or Energy Truss 1,587 49.0 0.0 0.020 32 Wall 1:Wood Frame, 16"o.c. 115 21.0 0.0 0.057 5 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 31 0.290 9 Wall 2: Wood Frame, 16" o.c. 40 21.0 0.0 0.057 2 Wall 3:Wood Frame, 16"o.c. 137 21.0 0.0 0.057 6 Window 2:Vinyl/Fiberglass Frame:Double Pane with Low-E 31 0.290 9 Wall 4: Wood Frame, 16"o.c. 40 21.0 0.0 0.057 2 Wall 5:Wood Frame, 16"o.c. 138 21.0 0.0 0.057 6 Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 8 0.290 2 Door 1: Solid 20 0.200 4 Wall 6: Wood Frame, 16"o.c. 160 21.0 0.0 0.057 8 Door 2: Solid 20 0.140 3 Wall 7: Wood Frame, 16" o.c. 220 21.0 0.0 0.057 13 Wall 8:Wood Frame, 16"o.c. 165 21.0 0.0 0.057 9 Wall 9:Wood Frame, 16"o.c. 283 21.0 0.0 0.057 14 Window 4:Vinyl/Fiberglass Frame:Double Pane with Low-E 36 0.290 10 Project Title: PLAN NO 1587-19 Report date: 05/13/19 Data filename: \\diskstation\Shared\REScheck\PLAN NO 1587-19-RUSSELL-QUEENSBURY.rck Page 1 of 2 Gross Area Cavi Cont. Assembly of R-Vale R-Value U-Factor UA Perimeter Wall 10:Wood Frame, 16"o.c. 50 21.0 0.0 0.057 3 Wall 11:Wood Frame, 16"o.c. 208 21.0 0.0 0.057 9 Window 5:Vinyl/Fiberglass Frame:Double Pane with Low-E 9 0.290 3 Door 3: Glass 40 0.280 11 Wall 12:Wood Frame, 16"o.c. 50 21.0 0.0 0.057 3 Wall 13:Wood Frame, 16"o.c. 120 21.0 0.0 0.057 6 Window 6:Vinyl/Fiberglass Frame:Double Pane with Low-E 14 0.290 4 Wall 14:Wood Frame, 16"o.c. 325 21.0 0.0 0.057 18 Window 7:Vinyl/Fiberglass Frame:Double Pane with Low-E 4 0.270 1 Basement Wall 1: Solid Concrete or Masonry 1,177 0.0 15.0 0.046 54 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement Wall 2: Solid Concrete or Masonry 69 19.0 0.0 0.045 3 Wall height:8.0' Depth below grade: 7.0' Insulation depth: 8.0' Basement Wall 3: Solid Concrete or Masonry 211 0.0 15.0 0.046 9 Wall height:8.0' Depth below grade: 7.0' Insulation depth: 8.0' Window 8:Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.290 5 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Jessica Chenier Bulman CAeyu.24, 3uipgadi, 05/13/19 Name-Title Sign re Date Project Title: PLAN NO 1587-19 Report date: 05/13/19 Data filename: \\diskstation\Shared\REScheck\PLAN NO 1587-19-RUSSELL-QUEENSBURY.rck Page 2 of 2 REScheck Software Version 4.6.5 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section ' Plans Verified Field Verified Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions &Req.ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the building envelope.Thermal ['Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ['Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, ;Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods ['Not Observable approved by the code official. Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PLAN NO 1587-19 Report date: 05/13/19 Data filename: Untitled.rck Page 3 of10 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions ,& Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F04]1 insulation R-value.Where interior R_ R- ❑Does Not table for values. insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall !❑Complies [F05]1 insulation installed per ❑Does Not manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft EComplies See the Envelope Assemblies [F06]1 insulation depth of burial or ❑Does Not table for values. , distance from top of wall. [Not Observable ❑Not Applicable 303.2.1 ;A protective covering is installed ❑Complies [F011]2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in. below grade. !❑Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [F012]2 controls installed. ElDoes Not 4 ' ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PLAN NO 1587-19 Report date: 05/13/19 Data filename: Untitled.rck Page 4 of10 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U- U- ElComplies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.5 ❑Not Observable [FR2]1 ❑Not Applicable 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not =, instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR2O]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 'sealed at housing/interior finish ❑Does Not and labeled to indicate:5.2.0 cfm ['Not Observable leakage at 75 Pa. ❑Not Applicable 403.3.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >= R-6 where < 3 inches.Supply and ❑Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ['Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R ❑Complies [FR17]z above 105°F or chilled fluids ❑Does Not below 55°F are insulated to>_R- 49i3 ❑Not Observable ENot Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not [Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are '❑Complies [FR1912 installed on all outdoor air ,❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PLAN NO 1587-19 Report date: 05/13/19 Data filename: Untitled.rck Page 5 of10 ` Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PLAN NO 1587-19 Report date: 05/13/19 Data filename: Untitled.rck Page 6 of10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values i❑Does Not provided. ['Not Observable ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least lh of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall [IN3]1 exterior,the exterior insulation ❑ Mass ❑ Mass ❑Not Observable requirement applies(FR10). III Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PLAN NO 1587-19 Report date: 05/13/19 Data filename: Untitled.rck Page 7 of10 • Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, 402.2.E ❑ Steel ❑ Steel ['Not Observable [FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. EDoes Not [Fl2]1 Blown insulation marked every 300 ft2. ['Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [FI3]1 insulation R-value of the ❑Does Not adjacent assembly. ['Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [FI17]1 ach in Climate Zones 1-2, and ElDoes Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ['Not Observable tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]1 determine air leakage with ft2 ft2 ElDoes Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ,❑Complies [F124]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [FI9]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. Not Applicable 403.1.2 Heat pump thermostat installed '❑Complies [FI10]2 on heat pumps. ❑Does Not [Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PLAN NO 1587-19 Report date: 05/13/19 Data filename: Untitled.rck Page 8 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system ❑Complies [FI25]2 "fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy ❑Not Observable and air flow limits. ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1,1 Heated water circulation systems ❑Complies [FI28]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply'; [Not Observable pipe.Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 s Electric heat trace systems ❑Complies [F129]2 comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically adjust the energy input to the ';❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units ❑Complies [F131]2 tested in accordance with CSA ❑Does Not <B55.1. Potable water-side pressure loss of drain water heat ['Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [F16]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ['Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ;❑Complies [F123]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PLAN NO 1587-19 Report date: 05/13/19 Data filename: Untitled.rck Page 9 of10 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 401.3 'Compliance certificate posted. ❑Complies [FI712 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: PLAN NO 1587-19 Report date: 05/13/19 Data filename: Untitled.rck Page 10 of10 20(4: 15 IE Energy Efficieny Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 0.00 Ceiling / Roof 49.00 Ductwork(unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.29 Door 0.28 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments