SEP-003383-2019 06072019INSPECTION WORKSHEET (SEP-003383-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:SEP-0363-2019Case Module:Permit
Inspection Date:Fri Jun 7, 2019Inspection Status:Passed
Inspector:Mark SmithInspection Type:Septic
Job Address:9 TIMMONS LNParcel Number:301.18-2-26
Queensbury, NY 12804
Contact TypeCompany NameName
ContractorIBS Septic
Granted PermissionPlatt, Victoria
Primary OwnerPlatt, Victoria
ApplicantIBS Septic
Checklist ItemPassedComments
Building Inspector NotesNO6/7/19 septic system approved. Existing 1000 gallon septic
tank with 200' of absorption field. gravity fed system.
Absorption field has a charcoal vent. Absorption field is very
deep.
Type of Water: Municipal / Well WaterYESMunicipal
Absorbtion Fields: Total LengthYES4 laterals at 50' each 200' total
Length of Each TrenchYES50'
Depth of TrenchesYES36 to 48" deep
Size of StoneYES#2
Jun 07, 2019Page (1)
INSPECTION WORKSHEET (SEP-003383-2019)
Checklist ItemPassedComments
Building to TankYESExisting
Tank to Distribution BoxYES4" SDR 35
Distribution box to Field / PitYES4" SDR 35 perforated
End CapYESEnds are looped with Charcoal filter
Manholes 12 or less below gradeYESManhole on outlet side of septic tank
Foundation to TankYES15'
Foundation to AbsorptionYES27'
Location of system on propertyYESSeptic tank is in backyard left side, absorption field is in
backyard
System Use StatusYESSystem approved
Smith, Mark (Inspector)