ResCheck , REScheck Software Version 4.6.5 co 1-1 Compliance Certificatecb { 1 0 cn L.::,F..: .:F. 3 C C.) 0 Project The Kimball �' 1t1N t ;�� � o9 ix ci) ti Energy Code: 2015 IECC i / <cDRtJP . � '��` a . 9� * _ in Location: Glens Falls, New York 10." r * , tt w a Construction Type: Single-family =` 3 Wus = C Project Type: New Construction my � ', 00 r LL Conditioned Floor Area: 1,965 ft2csç l/ + N C5 c Glazing Area 14% 0A ' ' '' �,( l'� (I) a Climate Zone: 6 (7635 HDD) ROFEss1C)NP % O Permit Date: 4 June, 2019 •00 V Permit Number: 0 C 0 Construction Site: Owner/Agent: Designer/Contractor: C 11 Wooden Lane Michaels Group Homes, LLC Queensbury, NY 1 Marions Way Mechanicville, NY Compliance: Passes using UA trade-off Compliance: 1.0%Better Than Code Maximum UA: 303 Your UA: 300 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Foundation Wall: Solid Concrete or Masonry 1,163 0.0 19.0 0.039 45 Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 7.6' lx 5030 Sliding Windows: Vinyl Frame:Double Pane with Low-E 15 0.300 5 2x Std. Basement Window: Vinyl Frame:Double Pane with Low-E 4 0.300 1 1st Floor Walls: Wood Frame, 24" o .c. 1,377 21.0 0.0 0.056 63 Foyer#1: Solid 21 0.170 4 2x Home Office (0): Vinyl Frame:Double Pane with Low-E 36 0.300 11 lx Stair(AC): Vinyl Frame:Double Pane with Low-E 4 0.300 1 2x Great Room (AP): Vinyl Frame:Double Pane with Low-E 11 0.300 3 2x Great Room (E):Vinyl Frame:Double Pane with Low-E 29 0.300 9 lx Great Room (R): Vinyl Frame:Double Pane with Low-E 27 0.300 8 #7 Breakfast: Glass 40 0.300 12 2x Dining (C): Vinyl Frame:Double Pane with Low-E 21 0.300 6 lx Dining (H): Vinyl Frame:Double Pane with Low-E 33 0.300 10 lx Mud (AC): Vinyl Frame:Double Pane with Low-E 4 0.300 1 Mud #20: Solid 19 0.170 3 Project Title: The Kimball Report date: 06/04/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\11 Wooden Lane.rck Page 1 of10 • Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter 2nd Floor Walls:Wood Frame, 24" o .c. 1,016 21.0 0.0 0.056 51 2x Bed #3 (AT):Vinyl Frame:Double Pane with Low-E 32 0.300 10 lx Master Bed (G): Vinyl Frame:Double Pane with Low-E 32 0.300 10 lx Master Bath (Q):Vinyl Frame:Double Pane with Low-E 12 0.300 4 lx Master Bath (AC):Vinyl Frame:Double Pane with Low-E 4 0.300 1 lx Main Bath (AC): Vinyl Frame:Double Pane with Low-E 4 0.300 1 lx Bed#2 (AT): Vinyl Frame:Double Pane with Low-E 16 0.300 5 lx Laundry(AS):Vinyl Frame:Double Pane with Low-E 10 0.300 3 Ceiling: Raised or Energy Truss 1,159 38.0 0.0 0.025 29 Floor Above Garage:All-Wood Joist/Truss:Over Unconditioned Space 115 30.0 0.0 0.033 4 Laundry Floor Above Porch:All-Wood Joist/Truss:Over Outside Air 14 30.0 0.0 0.033 0 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Keith D. Rupert, P.E. #P,"- June 4,2019 Name-Title Signature Date Project Title: The Kimball Report date: 06/04/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\11 Wooden Lane.rck Page 2 of10 RInspection EScheck Software VersionChecklist 4.6.5 0 Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the building envelope.Thermal ['Not Observable y, envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable 4.0 , Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: b Manual J or other methods :Not Observable J Btu/hr Btu/hr ❑Not Applicable approved by the code official. pp Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 13 Low Impact(Tier 3) Project Title: The Kimball Report date: 06/04/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\11 Wooden Lane.rck Page 3 of10 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F0411 insulation R-value.Where interior R- R- ❑Does Not table for values. v insulation is used,verification ID Observable may need to occur during Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [FO5]1 insulation installed per ❑Does Not �� manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [FO611 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]z to protect exposed exterior ❑Does Not insulation and extends a ❑Not Observable minimum of 6 in. below grade. ❑Not Applicable �403.9 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not b :Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 06/04/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\11 Wooden Lane.rck Page 4 of10 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable e+, ❑Not Applicable 402.1.1, Glazing U-factor(area weighted U- U ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, ❑ 402.5 Not Observable [FR2]1 ❑Not Applicable 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable taken from the default table. ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20]1 is listed and labeled as meeting Does Not ko, AAMA/WDMA/CSA 101/1.5.2/A440 :Not Observable or has infiltration rates per NFRC 400 that do not exceed code ❑Not Applicable limits. 1402.4.5 IC-rated recessed lighting fixtures ❑Complies ([FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate <2.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.3.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >= R-6 where<3 inches. Supply and ['Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.5 Building cavities are not used as ❑Complies [FR15)3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 QF or chilled fluids ❑Does Not below 55 QF are insulated to>_R- [Not Observable 3. ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not ) ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:The Kimball Report date: 06/04/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\11 Wooden Lane.rck Page 5 of10 • Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 06/04/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\11 Wooden Lane.rck Page 6 of10 s Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions &Req.ID 303.1 All installed insulation is labeled ❑Complies [1N13]2 or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel :Not Observable V' ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the ❑Not Observable underside of the subfloor, or floor framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value.If this is a R- R- ElComplies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ElDoes Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]1 exterior,the exterior insulation requirement applies(FR10). ❑ Steel Ill Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not [Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:The Kimball Report date: 06/04/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\11 Wooden Lane.rck Page 7 of10 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.6 [FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI2]1 Blown insulation marked every ❑Not Observable 300 ft'. ❑Not Applicable 1402.2.3 Vented attics with air permeable ❑Complies I[FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. [Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]1 insulation R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies [FI17]1 ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. :Not Observable ❑Not Applicable 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ❑Not Observable tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [FI24]1 by manufacturer at<=2%of ❑Does Not design air flow. ['Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [FI9]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. [Not Observable ❑Not Applicable I 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) j 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 06/04/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\11 Wooden Lane.rck Page 8 of10 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system ❑Complies [FI25]2 fans not part of tested and listed Does Not HVAC equipment meet efficacy and air flow limits. :Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [F126)2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [FI28]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply :Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [F129]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104QF. 403.5.4 Drain water heat recovery units ❑Complies [FI31]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat plot Observable recovery units< 3 psi for ❑Not Applicable individual units connected to one or two showers.Potable water- side pressure loss of drain water heat recovery units<2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [FI6]1 fixtures or 75%of permanent DDoes Not fixtures have high efficacy lamps. Does not apply to low-voltage :Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [F123)3 no continuous pilot light. ❑Does Not [Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 06/04/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\11 Wooden Lane.rck Page 9 of10 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 401.3 Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies 1[FI18]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable :Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:The Kimball Report date: 06/04/19 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\11 Wooden Lane.rck Page 10 of10 i20 IE C Efficie15ncyCC Energy Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 19.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.30 0.28 Door 0.30 0.28 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments