Loading...
ComCheck COMcheck Software Version 4.1.1.0 IP\Afil Interior Lighting Compliance - FILE COPY Project Information Energy Code: 2015 IECC Project Title: Glen Falls Center for Nursing and Rehabilitation Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: 152 Sherman Ave Greg Galiczewski Glen Falls, NY 2801 _ Edge Plus Co Architecture, LLC (] 4770 White Plains Road, First Floor Additional Efficiency Package(s) D U �L Bronx, NY 10470 11718-408-5100 JUL 15 info@edgeand.com 2019 REVIEWED FOR Unspecified TOWN OFQUEENSBURY ENERGY CODE COMPLIANCE Allowed Interior Lighting Power BUILDING&CODES A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Common Space Types:Office-Enclosed 1014 1.11 1126 Total Allowed Watts= 1126 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. 1-Common Spce Tyg ..Office- Enclosed LED 1:LED Panel 33W: 1 15 33 501 LED 2:Other: 1 1 48 48 LED 3:Other: 1 1 17 17 LED 4:LED Linear 33W: 1 1 30 30 LED 5:Other: 1 2 15 30 Total Proposed Watts= 626 nterior Lighting PASSES: Design 44%better than code Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. e LLP1:6 (;),AL-ic-2EwSF1 An NY 44t) ��0Nki• �,---- ---- --- ?ACM Name-Title Signature �,skED ARc,. Date / I 0 �yM. Gq�,c�0 4/ o c° ILI �4 * As,� b.,./, Nf 1 03 714'6 O42- Project Title: Glen Falls Center for Nursing and Rehabilitation OF NE Report date: 07/11/19 Data filename: C:\Users\Steve\Dropbox\20181SG18029A Glens Falls\Email\E-Mail I. - : •-I6-28\Glen Falls Page 1 of 5 Renovation.cck Settlon # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID ---C405.2.1 Lighting controls installed to uniformly OComplies (EL15]1 reduce the lighting load by at least ❑Does Not 50%. ONot Observable ONot Applicable C405.2.1 Occupancy sensors installed in OComplies (EL18]1 required spaces. ODoes Not ONot Observable ONot Applicable C405.2.1, Independent lighting controls installed OComplies C405.2.2. per approved lighting plans and all ❑Does Not 3 manual controls readily accessible and (EL2312 visible to occupants. ❑Not Observable ONot Applicable C405.2.2. Automatic controls to shut off all OComplies 1 building lighting installed in all ❑Does Not (EL22]Z buildings. ['Not Observable ONot Applicable C405.2.3 Daylight zones provided with OComplies [EL16)2 individual controls that control the ❑Does Not lights independent of general area lighting. ENot Observable ONot Applicable C405.2.3, Primary sidelighted areas are OComplies C405.2.3. equipped with required lighting ❑Does Not 1, controls. ❑Not Observable C405.2.3. 2 ONot Applicable (EL20)1 C405.2.3, Enclosed spaces with daylight area OComplies C405.2.3. under skylights and rooftop monitors ❑Does Not 1, are equipped with required lighting C405.2.3. controls. Not Observable 3 ONot Applicable (EL21]1 C405.2.4 Separate lighting control devices for ❑Complies IEL4)1 specific uses installed per approved ❑Does Not lighting plans. ONot Observable ONot Applicable C405.2.4 Additional interior lighting power OComplies (EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is ONot Observable automatically controlled and separated from general lighting. ONot Applicable C405.3 Exit signs do not exceed 5 watts per ❑Complies (EL611 face. ❑Does Not ❑Not Observable ONot Applicable Additional Comments/Assumptions: IJHigh Impact(Tier 1) L2J Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Glen Falls Center for Nursing and Rehabilitation Report date: 07/11/19 Data filename: C:\Users\Steve\Dropbox\2018\SG18029A Glens Falls\Email\E-Mail OUT\2019-06-28\Glen Falls Page 3 of 5 Renovation.cck A Project Title: Glen Falls Center for Nursing and Rehabilitation Report date: 07/11/19 Data filename: C:\Users\Steve\Dropbox\2018\SG18029A Glens Falls\Email\E-Mail OUT\2019-06-28\Glen Falls Page 5 of 5 Renovation.cck