ResCheck CREScheck Software Version 4.1.0
�J( Compliance Certificate
Project Title: ENGLEE RESIDENCE
Report Date:06/08/09
Data filename:C:\Program Files%Check\REScheck\ENGLEE RESIDENCE.rck RLE
j v `)
Energy Code: New York State Energy Conservation + ! j �(
Construction Code I
Location: Warren County,New York
Construction Type: Detached 1 or 2 Family
Heating Type: Non-Electric
Glazing Area Percentage: 17%
Heating Degree Days: 7635
Construction Site: OwnedAgent: Designertiontractor.
GLENS FALLS,NY 12801 JEFF ENGLEE STEVE NACUA
GLENS FALLS,NY 12801 HUDSON FALLS,NY 12839
STEVE@FRENCHMOUNTAINLOG
HOMESLLC.COM
Ccmpliance� Passes
Maximum UA:504 Your Home UA:476=5.6%Better Than Code
Gross Cavity Cont. Glazing UA
Assembly Area or R-Value R-Vaiue or Door
Perimeter U-Factor
Ceiling 1:Flat Ceiling or Scissor Truss 900 30.0 0.0 32
Ceiling 2:Flat Ceiling or Scissor Truss 420 30.0 0.0 15
Ceiling 3:Cathedral Ceiling(no attic) 520 30.0 0.0 18
Ceiling 4:Cathedral Ceiling(no attic) 520 30.0 0.0 18
Wall 1:Wood Frame,16'o.c. 240 11.0 0.0 19
Window 1:Wood Frame:Double Pane with Low-E 15 0.340 5
Window 2:Wood Frame:Double Pane with Low-E 15 0.340 5
Wall 2:Wood Frame,16"o.c. 160 11.0 0.0 14
Wall 3:Wood Frame,16"o.c. 180 11.0 0.0 14
Door l:Solid 21 0240 5
Wall 4:Wood Frame,16o-c. 112 11.0 0.0 7
Window 3:Wood Fmme:Double Pane with Low-E 30 0.340 10
W3!!5:Wood F yme,?5"^.c. 240 11.0 0.0 17
Window 4:Wood Frame:Double Pane with Low-E 11 0.340 4
Door 2:Glass 34 0240 8
Wall 6,Wood Frame,16'o 112 110 n n 7
Window 5:Wood Frame:Double Pane with Low-E 30 0.340 10
Wall 7:Wood Frame.16"o.c. 80 11.0 0.0 6
Window 6:Wom Frame:Double Pane with Low-E 15 0.340 5
Wall 8:Wood Frame,16"o.c. 160 11.0 0.0 14
Wall 9:Wood Frame. 16"o.c. 180 11.0 0.0 7
!^.1,dcw 7:Wood Fm�e:Double Pan_:":!h E 15 0.340 5
Window 7 copy 1:Wood Frame:Double Pane with Low-E 15 0.340 5
Window 9:Wood Frame:Double Pane with Low-E 12 0.350 4
Windnw 9 mpy 1:Wood Fmme'Dnuhin Pann with i.nw-F 12 0.350 4
Window 11:Wood Frame:Double Pane with Low-E 3 0.350 1
Window 11 copy 1:Wood Frame:Double Pane with Low-E 3 0.350 1
Door 3:0--= 41 0.210 10
Wag 10:Wood Frame,16o-c- 240 11.0 OA 16
Window 13:Wood Frame:Double Pane with Low-E 1s 0.340 5
EN'GLEE RESIDENCE ^age 1 vi 7
Window 14:Wood Frame:Double Pane with Low-E 15 0.340 5
Door 4:Glass 34 0.240 8
Wall 11:Wood Frame,16'o.c. 240 11.0 0.0 20
Window 15:Wood Frame:Double Pane with Low-E 15 0.340 0
Basement Wall 1:Solid Concrete or Masonry 555 11.0 0.0 48
Wall height 8.T
Depth below grade:6.0'
Insulation depth:6.0'
Basement Wail 2:Solid Concrete or Masonry 122 11.0 0.0 9
Wall height:8.T
Depth below grade:7.0'
Insulation depth:6.0'
Basement Wall 3:Solid Concrete or Masonry 104 11.0 0.0 8
Wall height 8.T
Depth below grade:7.0'
Insulation depth:6.0'
Basement Wall 3 copy 1:Solid Concrete or Masonry 104 11.0 0.0 8
Wall height.BY
Depth below grade:7.0'
Insulation depth:6.0'
Basement Wall 3 copy 2:Solid Concrete or Masonry 127 11.0 0.0 10
Wall height 8.T
Depth below grade:7.0'
Insulation depth:6.0'
Basement Wall 6:Wood Frame 99 11.0 0.0 6
Wall height:8.T
Depth below grade:7.0'
Insulation depth:8.0'
Basement Wall 7:Wood Frame 164 11.0 0.0 10
Wall height.8.T
Depth below grade:7.0'
Insulation depth:8.0'
Basement Wall 8:Solid Concrete or Masonry 9 11.0 0.0 1
Wall height:BY
Depth below grade:7.0'
Insulation depth:6.0'
Basement Wall 9:Solid Concrete or Masonry 90 11.0 0.0 7
Wall height:8.T
Depth below grade:7.0'
Insulation depth:6.0'
Basement Wall 10:Solid Concrete or Masonry 260 11.0 0.0 20
Wall height.B.T
Depth below grade:7.0'
Insulation depth:6.0'
Basement Wall 11:Solid Concrete or Masonry 260 11.0 0.0 20
Wall height 8.T
Depth below grade:7.0'
Insulation depth:6.0'
Fumace 1:Forced Hot Air90 AFUE
The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted
with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction
Code requirements.When a Registered Design Professional has stamped and signed this page,ttrey are attesting Brat to the best of
his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code.
Iry ai N eek r �� �� 1� o
Name-Title Signature Date
``4111r r/r1",
�% g NEW10
co °y •9�
jz]
ro
o
ENGLEE RESIDENCEp..VJ A •r 4`I'f Page 2 of 7
rREScheck Software Version 4.1.0
�(, Inspection Checklist
Date:06/08/09
Ceilings:
❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation
Comments:
❑ Ceiling 2:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation
Comments:
❑ Ceiling 3:Cathedral Ceiling(no attic),R-30.0 cavity insulation
Comments:
❑ Ceiling 4:Cathedral Ceiling(no attic),R-30.0 cavity insulation
Comments:
Above-Grade Walls:
❑ Wall 1:Wood Frame,16'o.c.,R-11.0 cavity insulation
Comments:
❑ Wall 2:Wood Frame, 16"o.c.,R-11.0 cavity insulation
Comments:
❑ Wall 3:Wood Frame,16"o.c.,R-11.0 cavity insulation
Comments:
❑ Wall 4:Wood Frame,16"o.c.,R-11.0 cavity insulation
Comments:
❑ Wall 5:Wood Frame,16"o.c.,R-11.0 cavity Insulation
Comments:
❑ Wall 6:Wood Frame,16"o.c.,R-11.0 cavity insulation
Comments:
❑ Wall 7:Wood Frame,16"o.c.,R-11.0 cavity insulation
Comments:
❑ Wall 8:Wood Frame,16"o.c.,R-11.0 cavity insulation
Comments:
❑ Wall 9:Wood Frame,16"o.c.,R-11.0 cavity insulation
Comments:
❑ Wall 10:Wood Frame,16'o.c.,R-11.0 cavity insulation
Comments:
❑ Wall 11:Wood Frame,16"o.c.,R-11.0 cavity insulation
Comments:
Basement Walls:
❑ Basement Wall 1:Solid Concrete or Masonry,8.7'ht/6.0'bg/6.0'insul,R-11.0 cavity insulation
Comments:
❑ Basement Wall 2:Solid Concrete or Masonry,8.7'ht/7.0'bg/6.0'insul,R-11.0 cavity insulation
Comments:
❑ Basement Wall 3:Solid Concrete or Masonry,8.7'ht/7.0'bg/6.0'insul,R-11.0 cavity insulation
ENGLEE RESIDENCE Page 3 of 7
Comments:
❑ Basement Wall 3 copy 1:Solid Concrete or Masonry,8.7'ht/7.0'bg/6.0'insul,R-11.0 cavity insulation
Comments:
❑ Basement Wall 3 copy 2:Solid Concrete or Masonry,8.7'ht/7.0'bg/6.0'Insul,R-11.0 cavity Insulation
Comments:
❑ Basement Wall 6:Wood Frame,8.7'ht/7.0'bg/8.0'insul,R-11.0 cavity Insulation
Comments:
❑ Basement Wall 7:Wood Frame,8.7"ht/7.0'bg/8.0'insul,R-11.0 cavity insulation
Comments:
❑ Basement Wall 8:Solid Concrete or Masonry,8.7'ht/7.0'bg/6.0'Insul,R-11.0 cavity Insulation
Comments:
❑ Basement Wall 9:Solid Concrete or Masonry,8.7'ht/7.0'bg/6.0'insul,R-11.0 cavity Insulation
Comments:
❑ Basement Wall 10:Solid Concrete or Masonry,8.7'ht/7.0'bg 16.0'Insul,R-11.0 cavity Insulation
Comments:
❑ Basement Wall 11:Solid Concrete or Masonry,8.T ht/7.0'bg/6.0'Insul,R-11.0 cavity insulation
Comments:
Windows:
❑ Window 1:Wood Frame:Double Pane with Low-E,1.1-factor.0.340
For windows without labeled 1.1-factors,describe features:
#Panes Frame Type Thermal Break?_Yes-No
Comments:
❑ Window 2:Wood Frame:Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
Vanes_Frame Type Thermal Break?_Yes-No
Comments:
❑ Window 3:Wood Frams:Double Pane with Low-E,"dor.0.340
For windows without labeled U-factors,describe features:
#Panes-Frame Type Thermal Break?-Yes_No
Comments:
❑ Window 4:Wood Frame:Double Pane with Low-E.U-factor:0.340
For windows without labeled U-tactors,describe features:
#Panes-Frame Type Thermal Break?_Yes-No
Comments:
❑ Window 5:Wood Frame:Double Pane with Low-E,U-factor.0.340
For windows without labeled U-factors,describe features:
#Panes-Frame Type Thermal Break?-Yes_No
Comments:
❑ Window 6:Wood Frame:Double Pane with Low-E.U-factor:0.340
For windows without labeled 1.1-factors,describe features:
Wanes-Frame Type Thermal Break?_Yes_No
Comments:
❑ Wrndow 7:Wood Frame:Double Pane with Low-E.U-factor.0.340
For windows without labeled 1.1-factors,describe features:
#Panes-Frame Type Thermal Break?_Yes-No
Comments:
'❑ Window 7 copy 1:Wood Frame:Double Pane with Low-E,1.1-factor.0.340
ENGLEE RESIDENCE Page 4 of 7
For windows without labeled U-factors,describe features:
#Panes—Frame Type Thermal Break?—Yes_No
Comments:
❑ Window 9:Wood Frame:Double Pane with Low-E,U-factor:0.350
For windows without labeled U-factors,describe features:
Vanes—Frame Type Thermal Break?_Yes—No
Comments:
❑ Window 9 copy 1:Wood Frame:Double Pane with Low-E,U-factor.0.350
For windows without labeled U-factors,describe features:
#Panes—Frame Type Thermal Break?_Yes_No
Comments:
❑ Window 11:Wood Frame:Double Pane with Low-E,11.1-factor:0.350
For windows without labeled 1.1-factors,describe features:
Vanes—Frame Type Thermal Break?_Yes_No
Comments:
❑ Window 11 copy 1:Wood Frame:Double Pane with Low-E,U-factor:0.350
For windows without labeled U-factors,describe features:
Vanes—Frame Type Thermal Break?—Yes No
Comments:
❑ Window 13:Wood Frame:Double Pane with Low-E,U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes—Frame Type Thermal Break?_Yes_No
Comments:
❑ Window 14:Wood Frame:Double Pane with Low-E.U-factor:0.340
For windows without labeled U-factors,describe features:
#Panes_Frame Type Thermal Break?_Yes—No
Comments:
❑ Window 15:Wood Frame:Double Pane with Lovv-E,U-factor.0.340
For windows without labeled U-factors,describe features:
#Panes—Frame Type Thermal Break?_Yes_No
Comments:
Doors:
❑ Door 1:Solid,U-factor:0.240
Comments:
❑ Door 2:Glass,1.1-factor:0.240
Comments:
❑ Door 3:Glass,U-factor:0.240
Comments:
❑ Door 4:Glass,1.1-factor.0.240
Comments:
Heating and Cooling Equipment:
❑ Furnace 1:Forced Hot Air:90 AFUE or higher
Make and Model Number.
Air Leakage:
❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5'clearance from
combustible materials.If non-IC rated,fixtures are installed with a 3'clearance from insulation.
ENGLEE RESIDENCE Page 5 of 7
Vapor Retarder:
Li Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
Materials and equipment are installed in accordance with the manufacturer's installation insf,mii�—
F-I Materials and equipment are identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
O Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building plans or specifications.
71 Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a
manner that achieves the rated R-value without compressing the insulation.
Duct Insulation:
Supply ducts in unconditioned attics or outside the building are insulated to R-11.
n Return ducts in unconditioned attics or outside the building are insulated to R-6.
Supply ducts in unconditioned spaces are insulated to R-11.
Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in
basements.
Duct Construction:
❑ All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,
or tapes.Tapes and mastics are rated UL 181 A or UL 181 B.
Exceptions:
Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa).
O The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest
zone.
Electric Systems:
Lj Separate electric meters exist for each dwelling unit.
Fireplaces:
Lj Fireplaces are installed with tight fitting noncombustible fireplace doors.
Lj Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York
State,the Residential Code of New York State or the New York City Building Code,as applicable.
Service Water Heating:
FI Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat
trap or is part of a circulating system.
❑ Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
O Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools have an ontoff heater switch and a cover unless over 20%of the heating energy is from non-depletable
sources.Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
Lj HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
ENGLEE RESIDENCE Page 6 of 7
Table 1:Minimum Insulation Thickness for Circuladng Hot Water Pipes
Insulation Thickness In Inches by Pipe Sizes
Non-Circulating Runouts Clrculating Mains and Runouls
Healed Water
Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140.169 0.5 0.5 1.0 1.5
100-139 0.5 0.5 0.5 1.0
Table 2:Minimum Insulation Thickness for HVAC Pipes
Fluid Temp.
Insulation Thickness In Inches by Pipe Sizes
Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0' 2.5"to 4"
Heating Systems
Low Pressurelfempereture 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0
Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD:(Building Department Use Only)
ENGLEE RESIDENCE Page 7 of 7