Loading...
ResCheck203-013, Permit Number MECcheck Compliance Report Checked By/Date Proposed New York State Energy Conservation Construction Code MECcheck Software Version 3.3 Release 1b Data filename:C:\My Documents\Roberts Residence.cck TITLE:"The Roberts Residence"aecene> COUNTY:Warren ah ys STATE:New York or syn HDD:7635 -oneNSeneCONSTRUCTIONTYPE:Detached 1 or 2 Family ONN SiG AND HEATING TYPE:Non-Electric Bue DATE:03/07/03, DATE OF PLANS:February 28,2003 COMPANY INFORMATION: Peter R.Weidman,General Contracting Dreamscapes Unlimited,Inc. COMPLIANCE:Passes ‘Maximum UA =459 ‘Your Home =351 23.5%Better Than Code Gross Glazing ‘Area or Cavity Cont.or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 1230 380 0.0 37 ‘Wall 1:Wood Frame,16"0.c.2326 «13.0 7.0 4Window1:Vinyl Frame,Double Pane with Low-E 356 0.320 114 Door I:Solid 38 0.400 15 Basement Wall I: Solid Concrete or Masonry,7.5!hv6.5'bg/7.5'insul 954 1100.0 62 Floor 1:All-Wood Joist/Truss,Over Unconditioned Space 336-380 (0.0 9 Fumace 1:Forced Hot Air,92 AFUE COMPLIANCE STATEMENT:The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been ‘designed to meet the Proposed New York State Energy Conservation Construction Code requirements, BuilderDesigner “Rabat Akane bunn Date_3-7-03 MECcheck Inspection Checklist Proposed New York State Energy Conservation Construction Code MECcheck Software Version 3.3 Release 1b DATE:03/07/03 TITLE:"The Roberts Residence" 1.Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation ‘Comments: Above-Grade Walls: 1.Wall 1:Wood Frame,16"o.c.,R-13.0 cavity +R-7.0 continuous insulation, Comments: Basement Walls: 1.Basement Wall 1:Solid Concrete or Masonry,7.5'hU/6.5'bg/7.5'insul, R-1L.0 cavity insulation Comments: Windows: 1.Window 1:Vinyl Frame,Double Pane with Low-E,U-factor:0.320 For windows without labeled U-factors,describe features: ##Panes____Frame Type.Thermal Break?[]Yes[]No ‘Comments: Doors: 1.Door I:Solid,U-factor:0.400 ‘Comments: Floors: 1.Floor 1:All-Wood Joist/Truss,Over Unconditioned Space,R-38.0 cavity insulation ‘Comments: Heating and Cooling Equipment: 1.Fumace 1:Forced Hot Air,92 AFUE or higher Make and Model Number Air Leakage: Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be Type IC rated and installed with no penetrations,or Type IC or non-IC rated installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials and 3"clearance from insulation. Vapor Retarder: Required on the warm-in-winter side ofall non-vented framed ceilings,walls,and floors. ‘Materials and equipment must be installed in accordance with the manufacturers installation instructions. ‘Materials and equipment must be identified so that compliance can be determined. ‘Manufacturer manuals for all installed heating and cooling equipment and service water heating | | | | | | | | | | | | | | | | I | | | | | | | | | | | | | | | I | | | | | | | | | | ! | | I | I equipment must be provided. Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Supply ducts in unconditioned attics or outside the building must be insulated to R-11 Return ducts in unconditioned attics or outside the building must be insulated to R-6, Supply ducts in unconditioned spaces must be insulated to R-L1. Return ducts in unconditioned spaces (except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duet Construction: All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes.Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. Cooling ducts with exterior insulation must be covered with a vapor retarder. Air filters are required in the return air system. The HVAC system must provide a means for balancing air and water systems. ‘Temperature Controls: Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electric meters are required for each dwelling unit. Fireplaces: Fireplaces must be installed with tight fitting non-combustible fireplace doors. Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the ‘water heater has an integral heat trap or is part ofacirculatingsystem. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. ‘Swimming Pools: All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources.Poo!pumps require a time clock. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the levels in Table 2. Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes. ‘Heated Water ‘Non-Circulating _Runouts ‘Temperature (F) Uptol”Upto1.25"Lfio20 Over2* 170-180 0s 1.0 2.0 140-160 05 05 10 15 100-130 05 05 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thicknessin InchesbyPipe Sizes Range(F)2”Runouts 1"andLess 1.25"to2"2.5"tod"Heating Systems Low Pressure/Temperature 201-250 1.0 iG 15 20 Low Temperature 120-200 0.5 1.0 10 15 Steam Condensate (for feed water)Any 1.0 10 15 20 Cooling Systems Chilled Water,Refrigerant,40-55 0.5 05 0.75 1.0 and Brine Below40 1.0 1.0 15 15 NOTES TO FIELD (Building Department Use Only)