Loading...
2008-368 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number. P20080368 Date Issued: Friday, May 29, 2009 This is to certify that work requested to be done as shown by Permit Number P20080368 has been completed. Tax Map Number. 523400-316-013-0001-023-000-0000 Location: 16 BARDIN Dr Owner. DANIEL & KELLY BARDIN Applicant: DANIEL & KELLY BARDIN This structure may be occupied as a: Deck By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, ' Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. �......_ w._....w.........e..ws..._...........................w..r ? .r♦. . .......... Ly�J` FFICE USE ONLY TAX MAP NO. PERMIT NO, FEE PAID BLDG.&CODES APPROVAL r ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION Use this application for any structure other than the Principal Structure (house)to include, but not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures-Sheds/Fences. A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT. t � �� OWNER ( \ ,P�IU L 0 INSTALLER/BUILDER: a��C / ADDRESS: ADDRESS: dA Ufn�b 0A PHONE NOS. `l �J PHONE NOS, LOCATION OF PROPERTY: SUBDIVISION NAME: LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: ESTIMATED COST OF CONSTRUCTION: $ lL}"-�' ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? IF YES,PLEASE LIST: CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: PHONE: aT NO PROPOSED PROPOSED CONSTRUCTION 1 FLOOR 2 FLOOR TOTAL HEIGHT SQ.FT. SQ.FT. SO.FT. FT.&IN. Of l a x 1 a DECK 3 SEASON,COVERED OR ENCLOSE H" BOATHOUSE BOATHOUSE WITH SUNDECK DOCK SHED POLE BARN DETACHED GARAGE(NO.OF CARS:____) OTHER ACCESSORY STRUCTURE: *CONSIDERED FLOOR AREA&MUST COMPLY WITH FAR[FLOOR AREA RATIO]REQUIREMENTS IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge,the statements contained in the application,together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes,the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all new construction. QUESTIONS? CALL 761-8256 OR EMAIL SodesOaueensbury.net 1 have read and agree to the above. VISIT OUR WEBSITE FOR MORE INFORMATION Signed Dated: www.a�ueensburv.net Town of Queensbury- Community Development Office - 742 Bay Ruud, Queensbury, NY"12804 B 1-LGL 11-05 // ' Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/ Depart: =� 'nwpm Date Inspection request received: d Inspector's Initials: LIV NAME: -Ark �i PERMIT#: LOCATION: DATE: t^ TYPE OF STRUCTURE: Comments: Yes No WA 4' Building Number Address visible from road Chi /'B•Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 indhes Roof Corroft/Exterior Finish Complete Platforrn at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more r Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall _ Interior/Exterior Railings 34 inches to 38 inches Deck Brad /HarKlicapped Rarnp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off e /regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Mcnen watertight Safety gWzhV/Window in stairwells safety glazM Interior Smoke Detectors/Carbon Monoxide Dethdors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft:150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below►grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Va s installed/Heat Tra t Water Temp 110 Enclosed Stairs Sheetrodk Underside minimum''Gypsum Basement stairs dosed rise>4 inches Garage Floor Pddied Garage fireproofing/%hour fire door/door closer Duct work Sealed property Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bond' As Built Septic System/Sewer Dept. ns n Sticker Site Plan /Variance required Flood Plain Certification,if reguhed Okay to issue C/C or C 10 Tern /Permanent L:1Building&Codes Forms\BuHding&Codes\lnspec ion Forms\Resklential Final Inspection Form_revised_100405.doc;Revised January 7,2008 (3 4 /1/0� Queensbury Building & Code Enforcement - Residential Find Inspection Office No. (518)761-8256 Arrive: am/pm Depa ~ am/pm Date Inspection re uest receiv Inspector's Initials: NAME: PERMIT#: LOCATION: DATE: TYPE OF STRUCTURE: Comments: Yes No NIA 4' Building Number Address visible from road Chimney Height/"S'Vent/Direct Vent Location Fresh Air Intake2 n M e _ C 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs deckspatios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safe glazing/Window in stairwells safety glazina Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: ` Outside every bedroom area: Inter Connected: Batterybacku Attic access 30 inches x 22 inches x 30 inches(height)in accessible area ;71 Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 s .ft.vents Bathroom Fans,if no window ' Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area -�—' Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum''Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed Properiv Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C I C or C 10 Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Fonn_revised_100405.doc;Revised January 7,2008;Revised 6/26/08 dn I I ` AV•/ _ MWI- �6 - 0 A C f ; 17 to- V�L co g! j not ,^c E c: y the pja' pen.- IZ to / q o ccaijzif,, 7:• 4 Ulp v u : I t Page I of I iz-o Fil c Zo N- ILI Up file://C:\Documents and Settings\dan\Lqcal Settings\Temporary lntemetFiles\Cqntent.Outl... 7/7/2008 Based on Actual Deck Height 2x4 Treated Lumber 2x12 Treated Lumber 1'-2 f 1'-24'/ -2x8x16 Concrete Patio Stone T-816" 1'-2q" on 2"Sand or Crushed Rock Base Stair Framing Plan i I SCALE:f C• 3/8"- V 0" 5/4x6 Treated or Composite Lumber;Typ. 3'-816" Stair Decking Plan �I SCALE:f E:3/8"= V_0" Floating 12x12 24d DEKBRANDS and amforBLOCK Live Technical Support are trademarks of Proshop Plans Foundation Co.These plans exclusively rconsyfor 1-800-664-2705 DeckSystems use only.Licensed a rand vey for y use with Dek-Block brand piers. 7 Days a Week 365 Days a Year DekBrands PO Box 14804 Mpls,MN 55414 1 www.DECKPLANS.com Copyright 2004 Proshop Plans Co. (5:00 am-9:00 pm CST) DEKBRANDS and Dek-Block are trademarks of Proshop Plans Co.,Inc.U.S.Patent 5,392,575,5,953,874,6,324,801 B1,6,446,403B2,6,550,20182,and 6,609,34662 Pat.Pend/App.Pend. 0& 12'-0" 2'-74rr 9r-43" 2x6 Treated Blocking Boards; Along Pool Edge; 1-2" Out from Coping 1'-4" 1 r-Orr 2x6 Treated Lumber; Typ. 2'-74" 1 r-4n 9'-8" 11-4" 1 0'-611 1'-4" 10'-2"— 12'-0" 11-4" 10'-2" 6'-92" 1'-4" 10'-2" 1 r-4r1 10'-6" 1 r A" -`t 9'-8" 2'-74" 1'-4rr 45° 3'-816" 2'-74,r 9,-44rr �. 024' POOL t Framing Plan �� SCALE: 1/2"= 1'-0„ Floating 12x12 24d DEKBRANDS emarks d Proshop Live Technical Support are trademarks of Proshop Plans Foundation Co.These plans are for consumer 1-800-664-2705 Deck Systems use only.licensed exdusivety for use with Dek-Block brand piers. 7 Days a Week-365 Days a Year DekBrands PO Box 14804 Mpls,MN 55414 www.D E C KP LAN S.com Copyright 2004 Proshop Plans Co. (5:00 am-9:00 pm CST) DEKBRANDS and Dek-Block are trademarks of Proshop Plans Co.,Inc.U.S.Patent 5,392,575,5,953,874,6,324,801B1,6,446,40382,6,550,201B2,and 6,609,346132 Pat.Pend/App.Pend. J NO c=1N N N N �� Dek-Block Brand Pier; Typ. /M Block Layout Elevation �� SCALE. 1/2 - 1 -0 2x6 Treated Lumber; Typ. Site Verify 2x4 Diagonal Bracing Between 4x4 Posts Around Perimeter of Deck Framing Elevation �I SCALE: 1/2"= 1'-0" 5/4x6 Treated or Composite Lumber; Typ. 1„ 2 Site Verify Decking Elevation J SCALE: 1/2"= 1'-0" FloatingDEKBRANDS and DEK-BLOCK are trade marks of Proshop Plans Live Technical Support Foundation 12x12 24d Co.These plans are for consumer 1-800-664-2705 Deck Systems use only.Licensed exclusively rand ier for use with Dek-Block brand piers. 7 Days a Week-365 Days a Year DekBrands PO Box 14804 Mpls,MN 55414 www.D E C KP LAN S.com Copyright 2004 Proshop Plans Co. (5:00 am-9:00 pm CST) DEKBRANDS and Dek-Block are trademarks of Proshop Plans Co.,Inc.U.S.Patent 5,392,575,5,953,874,6,324,801B1,6,446,40382,6,550,201B2,and 6,609,34662 Pat.Pend/App.Pend. Stair Elevation 1 SCALE: 3/8" = 1'-0" 2x4 Treated or Cedar Lumber; Typ. 5" Max. 2x6 Treated or Cedar Lumber; Typ. 3'-0" 4x4 Precut Handrail Post; Typ. 0 1 0 0 42" -2x2 Treated or Cedar Spindles; Typ. (Beveled at One End) QN Secure w/two - 1/2" x 4-1/2" Galy. Lag Bolts w/Washers Typical Handrail Elevation 2 SCALE: 1/2"= 1'-0" C-A O F— a i�- , �r i�- 1-�`. co T bIOCK Layout Cleyayon SCALE: 1/2" = 1'- 0" 2x6 Treated Lumber; Typ. Site Verify 2x4 Diagonal Bracing Between 4x4 Posts Around Perimeter of Deck Framing Elevation 4:11 SCALE:I E: 1/2" - 1'_0" 5/46 Treated or Composite Lumber; Typ. 2 Site Verify