2008-369 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building &Codes (518) 761-8256
CE RT I F I CAT E OF COMPLIANCE
Permit Number. P20080369 Date Issued: Tuesday, January 04, 2011
This is to certify that work requested to be done as shown by Permit Number P20080369
has been completed.
Tax Map Number. 523400-290-017-0001-009-000-0000
Location: 19 HERITAGE Pt
Owner. FREDERICK & MARY FIELD JR
Applicant: FREDERICK & MARY FIELD JR
This structure may be occupied as a:
Porch
By Order of Town Board
TOWN OF QUEENSBURY
. .,�
0.
Issuance of this Certificate of Compliance DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20080369 Application Number. A20080369
Tax Map No: 523400-290-017-0001-009-000-0000
Permission is hereby granted to: FREDERICK&MARY FIELD JR
For property located at: 19 HERITAGE Pt
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: FREDERICK&MARY FIELD JR
19 HERITAGE Pt Porch $10,000.00
QUEENSBURY,NY 12804-0000 Total value $10,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans &Specifications
2008-369
192 sq ft porch
$40.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Friday,July 17,2009
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expirationdate.)
Dated at the T of ee r u /Arsday,July 17, 2008
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
- C.�Db / ,--- •----`OFFICE USEONLY --_----___ _--__-% ------------------',
TAX MAP NO.____��_ ________PERMIT NO,
" - -- -- - r
FEE PAID BLDG.&CODES APPRO --------- r r
, r
" r ,
"......................................... ....-'' '-'--...---....----.....-�
ACCESSORY STRUCTURE BLII ING PERMIT APPLICATION
Use this application for any structure other than the Principal Structure(house)to include,but not limited to:
garage,shed,greenhouse,dock, deck,etc. Refer to Informational Brochure No. 3 entitled Accessory Structures-
Sheds/Fences.
A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID
PERMIT.NO INSPECTIONS WILL BE MADE/UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT.
OWNER:_!/Cpdt ! ! G/�_/ /CIA► ------------ INSTALLER/BUILDER:
/ a/fit° _[----------- --
ADDRESS: Ate-!'+/ ��' . ^=---- ADDRESS: %�9— C�16 ✓Icy /���_/V✓d5ca t — ���
PHONE NOS. 7+J_ 7 6 9_ _ PHONE NOS. 2q2 -- ----
LOCATION OF PROPERTY:------------------------------------ SUBDIVISION NAM E: -�- gjltla-,�- Park
=- ---- - -
LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: __r+cal _57�P____- �
ESTIMATED COST OF CONSTRUCTION: $,6�6U ANY OTHER ACCESSORY STRUCTURES ON PROPERTY?
IF YES,PLEASE LIST:_—_---- __ // ---_-------------
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE:_ �tyC C�cI✓c�r----------—PHONE:_—ZZZ=_X6 2
PROPOSED CONSTRUCTION 1s" No PROPOSED FLOOR 2 FLOOR TOTAL HEIGHT
SO.FT. SO.FT. SQ.FT. FT.&
OPEN PORCH
DECK
3 SEASON,COVERED OR ENCLOSED PORCH* 9z' )92' '9 9112
BOATHOUSE
BOATHOUSE WITH SUNDECK
DOCK
SHED
POLE BARN
DETACHED GARAGE(NO.OF CARS:---)
OTHER ACCESSORY STRUCTURE:
'CONSIDERED FLOOR AREA&MUST COMPLY WITH FAR[FLOOR AREA RATIO]REQUIREMENTS IF THE STRUCTURE IS LOCATED IN
THE WATERFRONT RESIDENTIAL ZONE.
To the best of my knowledge,the statements contained in the application,together with the plans and specifications
submitted,are a true and complete statement of all proposed work to be done on the described premises and that all
provisions of the Building Codes,the Zoning Ordinance,and all other laws pertaining to the proposed work shall be
complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that
/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance
being issued,as requested by the Zoning Administrator or Director of Building —
and Codes,an As-Built Survey by a licensed surveyor,drawn to scale, QUESTIONS? CALL 761-8256 OR EMAIL
showing actual location of all new construction. Codes(aD-QueensburV.net
I have read and agree to the above. VISIT OUR WESSITE FOR MORE INFORMATION
www.gueensbury.net
Signed---------- __ __ ___,Dated:�/� ��
Name/Title Printed ✓� e�L;14 L
Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804
.=1v10NWEALTII ELECT
Main Office 1�6 Doe Run AL INSPECTION SERVICE
MUNICIPAL,CERTIFICATE Road-Manheim,p INC.
- ELECTRICAL
f�sas
Permit No....... .. .... RICAL APPROVAL
Owner.,
' .Cert. ��
/`r2eyj�... �! G� - ut to C
..... 897 C
Location
... ............................. .. r
...................
....................................
Install `..�:.... ...............
atio
C, onsisting of.�. ...............
:L l C....vt'.. G1 cf'..
. ...T-, ' ..1.....2:��-`^•'���d ..........
.....................................................................................................
.......... ..........................
...................J?
..............................
Installed B
AC��.....................................................
...........
The conditions followin .................
cancelled:- g governed the issuance No.•"",.,,.•••"
of this certificate,
This certificate onlyand any certificate I of additiona equip
the electrical previously issued is
9uipment or alterations,ns7pa e�t and installation conditions
Inspectors of this Company snail have the
rules are violated,the Com application shalt be as of date. [�
Privilege of Prom tl Pon tnP
mak P y made for inspe�«'
/ Pany sha❑have the right to re inspections at any +:
Date.,f' �/ _ coke th' rtificate.
......................... INSPECTOR...
...........
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518) 761-8256 Arrive: am/pm�pe!part: am/pmDate Inspection request receiv Inspector's Initials. �(
NAME: PERMIT#: V
LOCATION: DATE: r
TYPE OF STRUCTURE:
Comments:
Yes No N/A
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location h a
Fresh Air Intake J
3 inch Plumbing Vent through roof minimum 18 inches ,ry/�I ve J
Roof Complete/Exterior Finish Complete !Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracin /Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safe glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification/Sticker on Panel
Floor truss,draft stopping finished basement 1,000 ,ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'/"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properdl 11
Gas Logs in Sealed or GI ss losure
Final Electrical
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C 10 Temporary/Permanent
LABuilding&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc; Revised
January 7,2008; Revised 6/26/08;Revised 12/22/10
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518) 761-8256 Arrive: Wesnitialsa
m/p lDgpart: am/pm
Date Inspection request recei ed: Inspect : ll//
NAME: PERMIT#:
LOCATION: DATE: /�-
TYPE OF STRUCTURE:
� Comments:
N WA
BuildingNumber Address visible from road 07
Chimney,Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Co late/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers _
Guards at stairs deckspatios more than 30 inches above grade
Guard at stairwell at 34 inches or more _
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handica Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate _
Gas Valve shut-off 2xposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches ei ht in aocessibie area
Crawl Spaces 18 inch x 24 inch access 1 ft:150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency ress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'A'Gypsum
Basement stairs dosed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed pro rl
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Finaf Surve Plot Plan
Arc Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Ins pection Sticker �rc"4J_ P
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C 10 Temporary/Permanent
LABuilding&Codes Form"uilding&Codesllnspection FormsWesidential Final Inspection Forrn_revised_100405.doc;Revised
January 7,2008;Revised 6d26/08
Queensbury Building & Code Enforcement - Residential Final Inspection
v
Office o. (518)761-8256 Arrive: am/pm rt: - am/pm
Date Inspection request mcetv Inspector's Initials:
NAME: /�' PE IT#:
LOCATION: L DATE: =
TYPE OF STRUCTURE:
Comments:
_Xej No MIA
4' Building Number Address visible from road a�
Chimney Height/"B'Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches -S '`r���' i k spe�-
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks, more than 30 indres above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railirw 34 inches to 38 inches
Deck Brad /Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch dearance to sill plate
Gas Valve shut-off e /regulator 18 indies above grade
Interior privacy/trim/doors/main entrance 36 inctres
Bathroom/IGtdren watertight
Safety glazing/Window in stakweUs safety g!g?�ng
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area: 1 '
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 Indies in aooessible area ��I,`�9►`'.
Crawl Spaces 18 inch x 24 inch access 1 sq.ft:150 sq.ft.vents
Bathroom Fans,if no window ✓
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Fumace shut-off at entrance to furnace area
Fumace/Hct Water Heater operating
Low water shut-off boiler 1
Relief Va s installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrodk Underside minimum W Gypsum
Basement stairs dosed rise>4 inches
Ganwe Floor Pihhed
Garage fireproofina/%hour fire door/door closer
Dud work Sealed properly
Gas Logs in Seated or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Are Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Phan Certification,if required
Okay to issue C/C or C 10 Tern /Pennanent
L folding&Codes Fomrsftiiding&Codesllnspection Fomrs%Resi kmW Final Inspection Form revised_100405.doc,Revised
January 7,2008
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date lns&qction uest received:
Queensbury Building &Code Enforcement Arrive: dam/ p am/pm
742 Bay Road, Queensbury, NY 12804 Inspect r�ls:
NAME: r, PERMIT# �
LOCATION: C9£= INSPECT ON: 5 v�
TYPE OF STRUCTURE:
Framing Y N WA COMMENTS:
Attic Access 220 x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls n'� D�✓Q 1���
Metal Strapping for Notches Top Plate U
1 '/2 w 16 gauge 8 16D naus each side
Draft stopping 1,000 sq. ft floor trusses
chor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. ("
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Forms-01-Muilding&Codesllnspection FomnslFraming Firestopping inspection Reportdoc Revised January 7,2008
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection uest received:
Queensbury Building&Code Enforcement Arrive: am/pm�D�part: am/pm
742 Bay Road,Queensbury,NY 12804 Inspectors Initials:
NAME: 14> PERMIT#:
LOCATION: /2 — INSPECT ON: _
TYPE OF STRUCT
Framing Y N N/A COMMENTS
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C. i
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %2 w) 16 gauge(8) 16D nails each side
raft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2,3 hour i
Fire wall 2, 3,4 hour
Firestopping
I
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation i
House side '/z inch or 5/8 inch Type X
Garage side 5/8 inch Type X j
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W) !
5.7 sf above/below grade
5.0 sf grade j
Framing / Flrestopping Inspection Report
Office No. (518)761-8256 Date In request received: � � Q
Queensbury Building &Code Enforcement Arrive: am/pm part: a
742 Bay Road, Queensbury, NY 12804 Inspect is Initials: .
NAME: e- 0 PERMIT
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
If Y I N WA COMMENTS
aming
Attic Access 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 Y2 w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall /V o r �.g� U
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceilingtwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Forms-QLDNBuilding&CodesUnspedion Fom►sTrarning Fire:topping inspection Reportdoc Revised January 7,2008