2008-385 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE OF 0CCUP-A-N- CY
Permit Number. P20080385 Date Issued: Tuesday, September 09, 2008
This is to certify that work requested to be done as shown by Permit Number P20080385
has been completed.
Location: 17 CLARK St
Tax Map Number. 523400-302-017-0004-02 1-000-0000
Owner. MICHAEL & SHIRLEY A GAZZILLO JR
Applicant: MICHAEL & SHIRLEY A GAZZILLO JR
This structure may be occupied as a:
Residential Addition By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
P Y
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development-Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20080385 Application Number: A20080385
Tax Map No: 523400-302-017-0004-021-000-0000
Permission is hereby granted to: MICHAEL& SHIRLEY A GAZZILLO JR
For property located at: 17 CLARK St
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Tyne of Construction Value
Owner Address: MICHAEL & SHIRLEY A GAZZIL
17 CLARK St Residential Addition $15,000.00
QUEENSBURY, NY 12804-0000 Total Value $15,000.00
Contractor or Builder's Name / Address Electrical Inspection Agency
Plans&Specifications
2008-385
140 sq ft residential addition
$75.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Thursday, August 06, 2009
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of Q ens W�dne y st 06, 2008
SIGNED BY for the Town of Queensbury.
Director of Building& Code Enforcement
�. .. �......... ...... .....
t'C �eFFICE USE ONLY........".,. ,
TAX MAP N PERMIT NO. � '
,
FEES: PER IT RECREATION ENGINEERING
(If applicable) ;
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
APPLICANT/BUILDEf. ` I1 C_ OWNER:w ` •�2 -' c�
ADDRESS: �l �^�� J�— ADDRESS: / � a-
PHONE NOS. �'7 L � PHONE NOS. 79 3 9)'10
CONTACT PERSON FOR BUILDING &CODES COMPLIANC E— c-.r &j V Cj( PHONE: ��
LOCATION OF PROPERTY:
SUBDIVISION NAME:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT p p a w U_ U)
APPLY TO YOUR
z p cn cn U) �..-w
PROJECT 0 O � � _ CL z
u- d z H t— O 1— = otS
Z Q 4 cA N c) O V. LL CL
SINGLE FAMILY I q OS
TW O-FAMILY
MULTI-FAMILY
(NO.of UNITS )
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(1,2,3)
OTHER
IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: �1
1��G FUEL TYPE: l 2'A-s ' -
ESTIMATED CONSTRUCTION COST:
HEAT TYPE ��{� *HOW MANY FIREPLACE(S): AND/OR WOODSTOVES(S):
: ��►'�.
ZONING CATEGORY: 3 ARE THERE WETLANDS ON THIS SITE?
IS THIS A HISTORIC SITE?_ Q
PROPOSED USE OF BUILDING OR ADDITION:
*Please complete a separate Application for"Fuel Burning Appliances&Chimneys" available in our office B 3-LGL 11-05
QTown of Queensbury a Community Development Office 1 742 Bay Road, Queensbury, NY 12804
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? Ml_
ARE THERE EASEMENTS ON PROPERTY? X16
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed In
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
Lve read and e a
Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction
codes or septic systems)
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
01
Permission is hereby granted to the above This application / proposed action described
Applicant to erect or alter the building 0 ; herein is found to be in accordance with the
described herein in accordance with said ; ; zoning Laws of the Town of Queensbury. 11
o
Application: 11
0 / 0
1 00
0 , ,
00
BUILDING & CODES APPROVAL ; ZONING APPROVAL 00
DATE DATE
0
QUESTIONS? CALL 761-8256 OR EMAIL
codesCc-gueensburv.net
VISIT OUR WEBSITE FOR MORE INFORMATION
Office Use Only www.queensbury.net
Operating Permit Issued: Yes No
Occupancy Type: � Construction Classification: Q
Assembly Occupancy Limit: Special Conditions:
Toum of Queensburyj • Community Development Office - 742 Bay Road, Queensbunj, NY 12804
r-----------------------------------
,
PROJECT NAME: OFFICE USE ONLY 10
STAFF INITIALS: ;
/ ,
DATE:
BUILDING PERMIT SUBMISSION ,
CHECKLIST FOR:
MULTIPLE DWELLING or COMMERCIAL PROJECTS
1. Building Permit Application Completed? ; YES 'NO ! N /A
2 Energy Form or Checkmate Energy Code Compliance I
Forms Complete? (2-copies)
3 1 Energy Code Inspector's Report from Checkmate
Program? (2-copies)
=4. 1
ic application completely filled out?
plicable)
5. Electrical Inspection Form complete?
F 1 t
6. Two (2) sets of the plans each of the following: I ~YES N N /A
a. Floor plans (s)?
b. Foundation plan?
c. Cross sections (s)?
4
i
d. Elevations? i
e. Design loads including floor, snow load, and wind
load?
+ f. Seismic design (required after January 2003)?
g. Plans signed and sealed by registered architect or
engineer?
_ ._._.__...._.
h. Window and door schedule? i
TTwo (2) site plans showing location of the structure to be
7 built, location of well or water lines, location of septic
Is
ystem or sewer line with all setbacks and separation
_ distances shown, and all improvements to the property?
8. Solid Fuel Burning or Gas Appliance Form (if applicable)? I
i
' 9. Driveway Permit
Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804
,__-_______ , _ __ _____________-
,' OFFICE USE ONLY '
PROJECT NAME: Z � ' ' 01
STAFF INITIALS:
0 0
/ f
BUILDING PERMIT SUBMISSION DATE:
CHECKLIST FOR: :_____
SINGLE FAMILY DWELLING
-, -- ----_ .._._._.. _—___----------------------------------_ - ----; --- ---
1 Building Permit Application Completed? YES NO N /A
Energy Form or CheckMate Energy Code Compliance
2' Forms Complete? (2-copies)
Energy Code Inspector's Report from Checkmate
3. Program? (2-copies) i
---.__ —___— ____--___._...._._._......._._.._......................_...._............_--.--.---.----._.._._._.. --
4 1 Septic application completely filled out?
j ' (if applicable) I
5. Electrical Inspection Form complete? j
6. I Two (2) sets of the plans each of the following: YES NO N /A
a. Floor plans (s)? I '
b. Foundation plan?
I
! c. Cross sections (s)?
I I-
d. Elevations? ✓ _i i
e. Window and door schedule? ' #
f. Natural Light, Ventilation and Emergency Egress
Requirements?
�g. Plans signed and sealed by registered architect or
engineer?
Two (2) site plans showing location of the structure to be
7. ` built, location of well or water lines, location of septic
s stem or sewer line?
8. 1 Setbacks from property lines to new structure? }
F Setbacks to neighboring wells and septic systems, —T— —T
8' ' including onsite well and septic systems 1f applicable)?
! i
9. i Driveway Permit?
s
_.s_.- ------ -----.-----------.__._..-----------.-.-.------..--_--.._._.__.._....--.-.---.----.__.__-____1____..__.__._1__.._._.____._.__�
Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804
B 12-LTR 11-05
r
i
a
4
i
��--�-- 0
y
i
-. p
Oil f �
C
to - . -
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518)761-8256 r Arrive: am/pm Depart: [I am/pm
Date Inspection request received: Inspector's initials:
NAME: ' �' ` l PERMIT#: C4 —3y-s
LOCATION: ! �j t DATE:
TYPE OF STRUCTURE:
Comments:
Y No WA
4' Building Number Address visible from road
Chimney t/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs,decks, more than 30 ktctm above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bras /Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy I trim/doors!main entrance 36 inches
Bathroom/Kddhen watertight
Safety gkuft/Window in staff wells safety g"
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Be"backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft:150 sq.ft.vents
Bathroom Fans,if no window
Plumb"Plumbina fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumaoe/Hot Water Heater operating
Low water shut-off boiler
Relief Va s installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum W Gypsum
Basement stairs dosed rise>4 inches
Garage Floor Pitched
Garage fweproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Arc Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C 10 Tern /Permanent
L:lBuilding&Codes Forms\Building&Codesilnspec don FormslResi hw"Final Inspection Form_revised_100405.doc;Revised
January 7,2008
COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.
Main Office 176 Doe Run Road-Manheim,PA 17545
MUNICIPAL C!RTIFICATE - ELECTRICAL APPROVAL
Permit No. .�.<„.... .,� t.....)...Cert. N 0 4580 Cut-in Card No.....................................
Owner......../11.......lp. AZ �.�...............
. ... ...........................................................................................................
Location.1.7....C.!_'.T. ,�``�.....��....../.` �...y.�..../....�..................Qt�4?/......�.............
Installation Consisting of.7... 7� �t.`o.. .�..�.. .....I.7..�: ... fir....`.... ......... ...........................
....................................................................................................................................................................................
...................................................................�/....../...............................................................................................................
Installed B e'TTI .E!�O./.5, .............................................Lic.No...................................................
The conditions following governed the issuance of this certificate,and any certificate previously issued is
cancelled:-
This certificate only covers the electrical equipment and installation conditions as of date. Upon the
introduction of additional equipment or alterations,application shall be promptly made for inspection.
Inspectors of this Company shall have the privilege of inspections at any time, and if its
rules are violated,the C(o�mpany shall have the right t voke his c if
............ .................. INSPECTOR ... ....... ............................................
Rough Plumbing / Insulation Inspection/Report
Office No. (518) 761-8256 Date Inspe 'on request received:
Queensbury Building & Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector' Initials:,�N-C,—
NAME: 2 j d PERMIT #: 3P
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbing /Nail Plates
Plumbing Vent/Vents in Place
1 Y2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
or 15 minutes
InsulatioQ Residential Check/Commercial Check
or Similar Exterior Sealant
Proper Vent, Attic Vent - 44
Door/Window Sealed No Insulation
Duct 1 Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly 1 No duct tape
COMMENTS:
Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building & Code Enforcement Arrive: am/pm art: a am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials,
NAME: Ct-Z,,�.� -C� PERMIT#:
LOCATION: i INSPECT ON:
TYPE OF STRUCTURE: IZJ2� L�D
Y N NIA
Rough Plumbing/Nail Plates
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S.I for 15 minutes
,Insulation/Residential Check/Commercial Check
ek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS: <�J_ -��
Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008
Framing / Firestopping Inspection Report
Once No. (518) 761-8256 Date Inspection request received: e S
Queensbury Building &Code Enforcement Arrive: am/pm Depart:t1 am/ m
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
i' e
NAME: G P, �-� "910 PERMIT
LOCATION: TT. INSPECT ON:
TYPE OF STRUCTURE:
Y N/A COMMENTS:
AeFraming
Attic Access 2T x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
17 O.C.
Headroom 6 ft. 8 in. -�-�
Stairwells 36 in. or more
Exterior Deck Bracing �1
Headroom 6 ft. 8 in. (j
Notches/ Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
ce and water shield 24 inches from wall
Fire separation 1, 2, 3 hair
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 518 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Forms-01-Muilding&CodesVropection ForntlFraming Firestopping Inspection Report.doc Revised January 7,2W8
/-3 a
Foundation Inspection Report
Office No.(518)761-8256 Date Ins�tionp6quest received:
Queensbury Building&Code Enforcement Arrive: :,- O) am/pm .Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: �'Z� Ai PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofng
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil po!y for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\lnspecdon Farms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
REScheck Software Version 4.0.1
Compliance Certificate
Report Date:07/10/08
Data filename: Untitled.rck
Energy Code: New York State Energy Conservation
Construction Code
Location: Washington County,New York
Construction Type: Detached 1 or 2 Family
Heating Type: Non-Electric
Glazing Area Percentage: 39%
Heating Degree Days: 7635
Construction Site: Owner/Agent: Designer/Contractor:
AssemblyGross Cavity Cont� Glazing UA
or or Door
Perimeter U-Factor
Ceiling 1:Flat Ceiling or Scissor Truss: 140 38.0 0.0 4
Wall 1:Wood Frame,16"o.c.: 272 21.0 5.0 8
Window 1:Wood Frame:Double Pane with Low-E: 105 0.310 33
Floor 1:All-Wood Joist/Truss:Over Outside Air: 140 38.0 5.0 3
Furnace 1:Forced Hot Air:97 AFUE
The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted
with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation Construction
Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of
his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code.
Name-Title Signature D e
Page 1 of 4
REScheck Software Version 4.0.1
Inspection Checklist
Date:07/10/08
Ceilings:
❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation
Comments:
Above-Grade Walls:
❑ Wall 1:Wood Frame, 16"o.c.,R-21.0 cavity+R-5.0 continuous insulation
Comments:
Windows:
❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.310
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Floors:
❑ Floor 1:All-Wood Joist/Truss:Over Outside Air,R-38.0 cavity+R-5.0 continuous insulation
Comments:
Heating and Cooling Equipment:
❑ Furnace 1:Forced Hot Air:97 AFUE or higher
Make and Model Number:
Air Leakage:
❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from
combustible materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation.
Vapor Retarder:
❑ Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment are identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
❑ Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building plans or specifications.
❑ Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a
manner that achieves the rated R-value without compressing the insulation.
Duct Insulation:
❑ Supply ducts in unconditioned attics or outside the building are insulated to R-11.
❑ Return ducts in unconditioned attics or outside the building are insulated to R-6.
❑ Supply ducts in unconditioned spaces are insulated to R-11.
❑ Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in
basements.
Duct Construction:
❑ All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,
or tapes.Tapes and mastics are rated UL 181A or UL 181 B.
Page 2 of 4
Exceptions:
Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa).
❑ The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest
zone.
Electric Systems:
Separate electric meters exist for each dwelling unit.
Fireplaces:
Fireplaces are installed with tight fitting non-combustible fireplace doors.
Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York
State,the Residential Code of New York State or the New York City Building Code,as applicable.
Service Water Heating:
Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat
trap or is part of a circulating system.
❑ Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable
sources.Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
Lj HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
Page 3 of 4
t
Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non-Circulating Runouts Circulating Mains and Runouts
Heated Water Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
Temperature(°F)
170-180 0.5 1.0 1.5 2.0
140-169 0.5 0.5 1.0 1.5
100-139 0.5 0.5 0.5 1.0
Table 2:Minimum Insulation Thickness for HVAC Pipes
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range ff) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0
Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD:(Building Department Use Only)
Page 4 of 4