2008-426 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
4z Community Development- Building &Codes (518) 761-8256
CERTIFICATE C'.)FE7 OCCUPANCY
Permit Number. P20080426 Date Issued: Friday, November 28, 2008
This is to certify that work requested to be done as shown by Permit Number P20080426
has been completed.
Location: 7 ANTHONY Ct
Tax Map Number. 523400-308-011-0001-012-000-0000
Owner. STEPHEN & KELLI MOORE
Applicant: STEPHEN & KELLI MOORE
This structure maybe occupied as a:
Garage Attached By Order of Town Board
TOV�N OF ENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve they/
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queembury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20080426 Application Number. A20080426
Tax Map No: 523400-308-011-0001-012-000-0000
Permission is hereby granted to: STEPHEN &KELLI MOORE
For property located at: 7 ANTHONY Ct
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: STEPHEN & KELLI MOORE Garage Attached $16,850.00
7 ANTHONY Ct Total Value $16,850.00
QUEENSBURY, NY 12804-0000
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans &Specifications
2008-426
572 SQ FT GARAGE
$57.20 PERMIT FEE PAID- THIS PERMIT EXPIRES: Friday,August 14,2009
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the T o ee rr �21Sdma ,August 14, 2008
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
....... ....../...................................... �. ....
OFFICE USE ONLY % ; -;
TAX MAP NO. ° PERMIT NO. ( � 1 c=-V ; "0 ._ ;
r
FEES: PERMIT,_ RECREATION ENGINEERING ;
(if appCicabte)
:........................................... .. r r.....................r
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OFA VALID
PERMIT
��FOR �
CONSTRUCTIONN..�tV5-
APPLICANTIBUILDER: �(�.� 1.5�YI�►N`''«�,� OWNER: c
ADDRESS: S C. ADDRESS:
PHONE NOS ' S�rh 1 +gsa`' PHONE NOS. J%0 41_I tQ
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: j,,J iP.-4tjmJgP PHONE: Z-47-9 M
XW0iMeo00t �sw�a�� 4106-40G
LOCATION OF PROPERTY: a1rU..1
SUBDIVISION NAME:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT Z
O
o ra
� Lou L
wAPPLY TO YOUR Z � a
O F C,,L
aUPROJECT L w
LU =
CY o i%z ¢ a O r
SINGLE FAMILY
TWO-FAMILY
MULTI-FAMILY
(NO.of UNITS__)
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED2 ,
GARAGE(1,2,3)
OTHER
IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS:.-
ESTIMATED CONSTRUCTION COST:,j,1t�a56 �� L TYPE:--1-`L-.
HEAT TYPE; *HOW MANY FiREPLACE(S): AIVD t OR WOODSTOVES(S) a N.t
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE?
IS THIS A HISTORIC SITE? `
PROPOSED USE OF BUILDING OR ADDITION: -s-arcat �ro �a y
*Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our afflce g 3-LGL 1 t-05
Town of Queensbury a Community Development Office • 742 Bay Road, Queensbury, NY 12804
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN?
ARE THERE EASEMENTS ON PROPERTY?
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read nd re o the a ve.
Signe
Director of Building.& Codes: 761-8256 (for questions regarding Building Permits, construction
codes or septic systems)
Zoninq Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
Permission is herebyranted to the above ;
g This application / proposed action described
Applicant to erect or alter the building herein is found to be in accordance with the
described herein in accordance with said Application: ; zoning Laws of the Town of Queensbury.
,
0 ,
/ ,
BUILDING &CODES APPROVAL ZONING APPROVAL
1 0 ,
DATIE
DATE
_•__._......................................J __._.______ _-_ •_J
QUESTIONS? CALL 761.8256 OR EMAIL
ROODSMUeensbuIv.not
VISIT OUR WESSITE FO MORE INFORMATION
WWWj
Town of Queensbury• Community Development Office • 742 Bay Road, Queensbury, NY 12804
D"y 1<a.
Queensbury, New York •12804 PLOT PLAN
Show all existing and proposed structures. Indicate the setbacks of all structures and buildings from all property lines.
SIDE PROPERTY LINE t
- Ar
,
i .
:
-n-
E
11S 5 _.,...
I 111 1 _
Z
� , r -,
U -v
,
- �_a —_� — i --
,
,
,
Q
1 ' 1
CC
p
1
__�...-711, 1',
l ✓� {
LL
�� ..___ _..__ ........_. ._...._,...._L.__.d_.—...�.._...a-.i--.�...�._.�.._.._..1..__....a_.,._.�_- � � ..._
SIDE PROPERTY LINE 1 SQUARE 5ay. 6 FT.
v
____
p11 •_j1__ OFFICE USE ONLY
PROJECT NAME: Wpmf7A�1�1 orL.. ;
STAFF INITIALS:
BUILDING PERMIT SUBMISSION ; DATE:
CHECKLIST FOR: '
SINGLE FATLY DWELLING
1. 1 Building Permit Application Completed? YES NO N/A
2 , Energy Form or CheckMate Energy Code Compliance
Forms Complete? (2-copies)
Energy Code Inspector's Report from Checkmate
3' Program? (2-copies) , f
j Septic application completely filled out? ' 1
4. (if applicable)
5. Electrical Inspection Form complete? I
t 3
6. ` Two (2) sets of the plans each of the following: YES NO N /A
a. Floor plans (s)? ;
3
{ b. Foundation plan?
c. Cross sections (s)?
3
d. Elevations? j
S
j i e. Window and door schedule?
f g. Plans signed and sealed by registered architect or
i engineer?
i 3
h. Window and door schedule?
i f
Two (2) site plans showing location of the structure to be
7. built, location of well or water lines, location of septic
system or sewer line?
8. Setbacks from property lines to new structure?
$ Setbacks to neighboring wells and septic systems,
including onsite well and septic systems (if applicable)? ,
9. Driveway Permit?
Town of Queensbury Community Development-Office- 742 Buy Road, Qusensbury, NY 12804
--------------------------------------
OFFICE USE ONLY
PROJECT NAME:
STAFF INITIALS: ;
BUILDING PERMIT SUBMISSION ; DATE:
CHECKLIST FOR: ------------- ----
MULTIPLE DWELLING r C PMERCIAL PROJECTS
1. Building Permit Application Completed? YES NO N/A
1
Energy Form or CheckMate Energy Code Compliance
2. Forms Complete? (2-copies)
3 , Energy Code Inspector's Report from Checkmate
! Program? (2-copies)
( 4 Septic application completely filled out?
(if applicable)
5. Electrical Inspection Form complete? '
;
i
e }
I
6. Two (2) sets of the plans each of the following: YES ? NO j N /A
t
I j a. Floor plans (s)? I
i I ;
j
i b. Foundation plan?
I
c. Cross sections (s)? I f
e 3
d. Elevations? 1 I
e. Design loads including floor, snow load, and wind -- ---
F load?
f. Seismic design (required after January 2003)?
g. Plans signed and sealed by registered architect or
i
engineer?
h. Window and door schedule?
{
Two (2)site plans showing location of the structure to be
I built, location of well or water lines, location of septic
7' ; system or server line with all setbacks and separation i
distances shown, and all improvements to the property?
8. Solid Fuel Burning or Gas Appliance Form (if applicable)?
., I
I 9. Driveway Permit '
Town of Queensbury - Community Development Office 742 Say Road, Queensbury, NY 12804
Community Development Office
own of Queensbury • 742 Bay Road • Queensbury, New York •12804
Q / ,
• David Hatin,Director of Building&Codes 01
Craig Brown,Zoning Administrator
WINDOW SCHEDULE
JOB SITE/ADDRESS: Wua �y '' DATE: --��
OWNER: S�tG�IG "� VICW to 0 0 rye_ APPLICATION NO.:
WINDOW-
UNIT OR CLEAR CLEAR
WINDOW STOCK ROUGH ROUGH SQ.FT. OPENING
NO.OR WINDOW SQ.FT. OPENING SPECIAL HARDWARE OR
MANUFACTURER MODEL/TYPE WIDTH IN NUMBER OPENING OPENING EGRESS/CLEAR HEIGHT
LETTER NAME CALL WIDTH HEIGHT VENT OPENING IN INSTRUCTIONS
ON PLAN SIZE INCHES INCHES
283►o Mokm V i ew Z.00 2.1104 41 1#1 H D ,D 33
B 26-LTR 11-05
Queensbury Building & Code Enforcement - Residential F' Inspection
Office No. (518)761-8256 Arrive: am/p Depart: am/pm
Date Inspection request received: Inspectjr'snitials:
XNAME: PERMIT#: (/)(f
LOCATION: DATE: Z -
TYPE OF STRUCTURE:
Comments:
Yes No NIA
4' Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs deckspatios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate '
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Batterybacku :
Attic access 30 inches x 22 inches x 30 inches(height)in ac essible area
Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency ress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operatin
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum%"Gypsum
Basement stairs dosed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed ProperIv
Gas Logs in Sealod or VI.M EnrAM
Final Electrical
Final Survey Plot Plan
Arc Fault Breaker in Bedrooms
Flex Gas Pie Bonding,
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C 10 Temporary/Permanent
LABuilding&Codes FormslBuilding&Codes\Inspection FonmsWesidential Final Inspection Form_revised_100405.doc;Revised
January 7,2008; Revised 6/26/08
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received: C'
Queensbury Building&c Code Enforcement Arrive: am/pm Depart:1, 1 am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:/'
NAME: I''�I(G1 r',- - PERMIT#: ,
LOCATION: N" c INSPECT ON:
TYPE OF S1 C .
Comment
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
oundation/Wallpour 01
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofmg
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Fortes\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart:�pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: ' . ''�—_ PERMIT#: `Y
LOCATION: - INSPECT ON:
TYPE OF STRUCTURE: `
Comments
Y N N/A
Footings
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site. 01
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
¢T� .
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Dep am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: r PERMIT#: ( ZIZ�
��
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Comments
Y j N A
Footings 7 n
Piers ��•-
Monolithic Slab
Reinforcement in Place `T �The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place (�
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Rough Plumbing / Insulation Inspeoion Report
Office No. (518) 761-8256 Date Ins ec request received:
Queensbury Building &Code Enforcement Arrive: �. am/p .Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspectoks Initials: 'P. U
NAME: V %u PERMIT#:
LOCATION: INSPECT ON: 0
TYPE OF STRUCTURE:
Y N NIA
Rough Plumbing/Nail Plates
Plumbing Vent I Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/ Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
0 P.S.I for 15 minutes
Insulation/R sidential Check/Commercial Check
T ek ' ilar Exterior Sealant
ro er Vent Attic Vent
Door/Window Sealed No Insulation
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7, 2008
3 : &D
r
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm Depart: —am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: /
NAME: PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N NIA
Rough Plumbing/Nail Plates
Plumbing Vent/Vents in Place
1 Y2 inch minimum Drain Size
Washi2q Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S.I for 15 minutes
insulation/Residential Check/Commercial Check
ek or Similar Exterior Sealant
P o r Vent, Attic Vent
-'Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct worts sealed properly/ No duct tape
COMMENTS:
Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008
Framing / Firestopping Inspection eport
Office No. (518)761-8256 Date Inspecti
9a request received:
Queensbury Building S Code Enforcement Arrive 1-~ ;t am/pm�epart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT# 4
LOCATION: INSPECT ON: -
TYPE OF STRUCTURE:
Y N WA COMMENTS:
Framing
Attic Access 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 V2 w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
r Bolts SA,or less on center
Ice and water!hie 24 inches from wall
ration 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling1wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Forms-OLDABuilding&Codes\lnspec ion FormsTraming Fuss ping Inspection Report.doc Revised January 7,2008
t t —
Permit#
Permit Date
REScheck Software Version 3.7.3
Compliance Certificate
Project Title: Kelli & Steve Moore
Report Date:06/09/08
Data filename:Untitled.rck
Energy Code: New York State Energy Conservation
Construction Code
Location: Warren County,New York
Construction Type: Detached 1 or 2 Family
Heating Type: Non-Electric
Glazing Area Percentage: 7%
Heating Degree Days: 7635
Construction Site: Owner/Agent: Designer/Contractor:
Anthony Court Joel Fitzgerald
Queensbury,NY 12804 Oakwood Construction
25 Wayne Court
Queensbury,NY 12804
518-222-9852
Compliance: ..
Cont. Glazing
Assembly - •..
Ceiling 1:Flat Ceiling or Scissor Truss: 339 30.0 0.0 12
Wall 1:Wood Frame,16"o.c.: 478 19.0 0.0 27
Window 1:Vinyl Frame:Double Pane: 32 0.490 16
Floor 1:All-Wood JOISUTruss:Over Unconditioned Space: 52 30.0 0.0 2
The proposed building represented in this document is consistent with the building plans,specifications,and other calculations
submitted with this permit application.The proposed systems have been designed to meet the New York State Energy Conservation
Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that
to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code.
6AKWOOT) C0411 C:tz.cu,a,Qd fir--L 8:
Builder/Designer ompany Name Date
Kelli&Steve Moore Page 1 of 4
REScheck Software Version 3.7.3
Inspection Checklist
Date:06/09/08
edings:
Ceiling 1:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation
Comments:
/�bove-Grade Walls:
YJI Wall 1:Wood Frame,16"o.c.,R-19.0 cavity insulation
Comments:
Windows:
Window 1:Vinyl Frame:Double Pane,U-factor:0.490
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Floors:
loor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation
Comments:
Air Leakage:
ants,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed.
Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from
combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation.
apor Retarder:
Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
aterials Identification:
atedals and equipment must be installed in accordance with the manufacturer's installation instructions.
Jfaterials and equipment must be identified so that compliance can be determined.
[0 Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided.
Insulation R-values and glazing U-factors must be dearly marked on the building plans or specifications.
uct Insulation:
upply ducts in unconditioned attics or outside the building must be insulated to R-11.
FF,eptum ducts in unconditioned attics or outside the building must be insulated to R-6.
plyducts in unconditioned spaces must be insulated to R-11.
ducts in unconditioned spaces(except basements)must be insulated to R-
Retur ducts in unconditioned spaces(except basements)must be insulated to R-2.
Insulation is not required on return ducts in basements.
OAuct Construction:
All joints,seams,and connections must be securely fastened with welds,gaskets,mastics(adhesives),
mastic-plus-embedded fabric,or tapes.Tapes and mastics must be rated UL 181A or UL 181 B.
Jxception:
Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500
a).
he HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Kelli&Steve Moore Page 2 of 4
d'*'Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest
zone.
Zlectric Systems:
separate electric meters are required for each dwelling unit.
ji!replaces:
ireplaces must be installed with tight fitting non-combustible fireplace doors.
Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building
Code of New Yofk State,the Residential Code of New York State or the New York City Building Code,as applicable.
ervice Water Heating:
Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral
W l
eat trap or is part of a circulating system.
Insulate circulating hot water pipes to the levels in Table 1.
irculating Hot Water Systems:
Insulate circulating hot water pipes to the levels in Table 1.
imming Pools:
All heated swimming pools must have an on/off heater switch and require a cover unless over 20%of the heating energy is from
non-depletable sources.Pool pumps require a time clock.
eating and Cooling Piping Insulation:
HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table
2.
Kelli&Steve Moore Page 3 of 4
+U T
Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non-Circulating Runouts Circulating Mains and Runouts
Heated Water
Temperature("F) Up to 1" Up to 1.25" 1.5'to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-169 0.5 0.5 1.0 1.5
100-139 0.5 0.5 0.5 1.0
Table 2:Minimum Insulation Thickness for HVAC Pipes
Fluid Temp. insulation Thickness in Inches by Pipe Sizes
Piping System Types Range("F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0
Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD:(Building Department Use Only)
Kelli&Steve Moore _ Page 4 of 4