blower door resultsWappingers Falls OfficeAAPPOLO868BurdeckSteet95AiportDriveSuit HE ATTEN G Scteneciay,NY 12306,Wappingers Fall NY 12590 Tel (518)355-0433 Tel.(845)452-5400 Vestal Office 414 Commerce Road P.O Box 66 Vestal,NY 13851 Tel.(607)729-5847DegreesAboveTheRest,SCE /968/ax (518)355-3174 ‘Fax.(845)452-1606 Fax (607)797-7520 Property Address_|Wedgewood Dr Apartment Unit 17,Queensbury Ny Builder ‘Schermerhorn Date of test.1/31/2020 Model of Home Blower Door Test Level Square Feet Air Volume (Cu.Ft.) Dining 238 10 =|2380 1%Floor 302 9 2718 2nd Floor 539 9 4851 Total 1078 9949 Equipment Used ‘TEC Minneapolis Blower Door with TEC DG-1000 Manometer Fan Configuration BRing Measured CFMSO 492 Calculated ACHSO 3.0 Testing done in accordance with ASTM E 1827-11 Thereby certify and attest to the accuracy of the testing results Th Anelas 4 Aboree— Test performed by: Nick Abrunza Energy Auditor/ BPI Certification Number:5059019 aaFPOke Degrees Above The Rest,SCE 1968/ws appotoheating com Main Office 868 Burdeck Street Schenectady,NY 12306 Tel.(518)355-0433 Fax.(518)355-3174 ‘Wappingers Falls Office 95 Ainport Drive ~Suite | ‘Wappingers Falls,NY 12590 Tel,(845)452-5400 Fax,(845)452-1606 Vestal Omice 414 Commerce Road P.O Box 66 Vestal,NY 13851 Tel,(607)729-5847 Fax.(607)797-7520 Property Address Wedgewood Apartment Unit 21,Queensbury Ny Builder Schermerhorn Date of test 1/28/2020 Model of Home Blower Door Test Ceiling|Level Square Feet__|Height Air Volume (Cu.Ft.) Basement 1"Floor 1204 9 10836 2nd Floor Total 1204 10836 TEC Minneapolis Blower Door with TEC DG-1000 Equipment Used__|Manometer Fan Configuration_|8 Ring dMeasuredCFMS0_|480 Calculated ACHSO|2.7 Testing done in accordance with ASTM E 1827-11 Thereby certify and attest to the accuracy of the testing results Th Males 4 Aboe— Test performed by: Nick Abrunza Energy Auditor! BPI Certification Number:5059019 Main Office 868 Burdeck StreetAAPPOLOBete...Degrees Above The Rest,SICE 1968/Tel.(518)355-0433 Fax,(518)355-3174 Wappingers Falls Office 95 Aisport Drive~Suite | ‘Wappingers Falls,NY 12590 Tel.(845)452-5400 Fax.(845)452-1606 Vestal Office 414 Commerce Road P.O Box 66 Vestal,NY 13851 Tel,(607)729-5847 Fax,(607)797-7520wowappotohetingcom[Property Address|Wedgewood Apartments Unit 23,Queensbury Ny Builder Schermerhorn Date of test 1/31/2020 Model of Home Ceiling Level Square Feet Height Air Volume (Cu.Ft.) Basement 1*Floor 81 9 729 2nd Floor 1383 9 12447 Total 1464 13176 Blower Door Test TEC Minneapolis Blower Door with TEC DG-1000 Equipment Used_|Manometer Fan Configuration|B Ring Measured CFM50|665 Calculated ACH50|3.0 Testing done in accordance with ASTM E 1827-11 Thereby certify and attest to the accuracy of the testing results Th cneales A Abwte- ‘Test performed by:Nick Abrunza Energy Auditor/ BPI Certification Number:5059019