BINS-000314-2019 01142019 INSPECTION WORKSHEET (BINS-000314-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal CC-000362-2015Permit Case Number:Case Module: Mon Jan 14, 2019Partial Pass Inspection Date:Inspection Status: John O'BrienBuilding Framing Inspector:Inspection Type: 3-23 Wedgewood DR Bldg. 1302.9-1-28.1 Job Address:Parcel Number: Queensbury, NY 12804 Contact TypeCompany NameName ApplicantSchermerhorn R.E. HoldingsVANDERWARKER, DARREN Primary OwnerSCHERMERHORN WEDGEWOOD LLC Granted PermissionSchermerhorn Properties ContractorSchermerhorn R.E. HoldingsVANDERWARKER, DARREN ArchitectRucinski-Hall Architecture Checklist ItemPassedComments Building Inspector NotesNO6/1/18 Ice & Water Shield Approved 1/14/19 Framing Partial Approval- Preliminary Framing Remaining Items: - Complete nailing all truss bracing at gable ends. Some areas missing blocks and some are not nailed. - One H4 2nd Floor shear hold down missing lower bracket at middle unit front elevation. - Check all stair landings joist hangers for missing nails. - Provide Ethan Hall's Framing Inspection Report. Jan 14, 2019Page (1) INSPECTION WORKSHEET (BINS-000314-2019) Checklist ItemPassedComments FramingNO1/14/19 Framing Partial Approval- Preliminary Framing Remaining Items: - Complete nailing all truss bracing at gable ends. Some areas missing blocks and some are not nailed. - One H4 2nd Floor shear hold down missing lower bracket at middle unit front elevation. - Check all stair landings joist hangers for missing nails. - Provide Ethan Hall's Framing Inspection Report. Attic Access 22 x 30 minimumNO Jack Studs HeadersNO Continuous Header for Garage Doors withNO Straping Truss Specification ProvidedNO Bracing BridgingNO Hurricane Clips/Uplift Screws/Nail Holes FilledNO Air Seal all Plates and SillsNO Air Seal All Registers at FloorNO Air Sealing all Joints Before InsulationNO Joist hangersNO Jack Posts Main BeamsNO Exterior sheeting nailed properlyNO Jan 14, 2019Page (2) INSPECTION WORKSHEET (BINS-000314-2019) Checklist ItemPassedComments 12 O.C.NO Headroom 6 ft. 8 in.NO Notches Holes Bearing WallsNO Metal Strapping for Notches Top PlateNO Draft stopping 1,000 sq. ft. floor trussesNO Anchor Bolts 6 ft. or less on centerNO Ice and water shield 24 inches from wallYES6/1/18 Ice & Water Shield Approved Soffits-Insulation BaffelNO Windows Habitable Space BedroomsNO 24 in. (H)NO 20 in. (W)NO 5.7 sf above below gradeNO 5.0 sf gradeNO Design Professional Sign-off, if requiredNO O'Brien, John (Inspector) Jan 14, 2019Page (3)