BINS-000359-2019 01172019
INSPECTION WORKSHEET (BINS-000359-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
CC-000364-2016Permit
Case Number:Case Module:
Thu Jan 17, 2019Partial Pass
Inspection Date:Inspection Status:
John O'BrienBuilding Framing
Inspector:Inspection Type:
27, 29, 33, 35, 39, 41, 45, 47 Wedgewood302.9-1-28.1
Job Address:Parcel Number:
DR Bldg. 3
Queensbury, NY 12804
Contact TypeCompany NameName
ArchitectRucinski-Hall Architecture
Primary OwnerSCHERMERHORN WEDGEWOOD
LLC
ApplicantSchermerhorn R.E. HoldingsVANDERWARKER, DARREN
ContractorSchermerhorn R.E. HoldingsVANDERWARKER, DARREN
Granted PermissionSchermerhorn R.E. HoldingsVANDERWARKER, DARREN
Checklist ItemPassedComments
Building Inspector NotesNO6/15/18 Ice & Water Shield Partial Approval
-Upper roof ok to shingle. I will check the balance on Monday
6/18/18
6/18/18 Ice & Water Shield Approved-Balance
1/17/19 Framing Partial Approval - Preliminary Framing
- Garage anchor bolts are missing in areas. They do not
meet 6' oc or less spacing. Spliced bottom plate anchoring
ok.
- Check stair landings for missing joist hangers
- Bridging missing at outside box area and in middle spans.
Just recheck after trades are done.
- Complete nailing all truss bracing at gable ends and at
changes to different truss locations. Some areas are missing
nailer blocks totally and some blocks are there but are not
nailed .
Jan 17, 2019Page (1)
INSPECTION WORKSHEET (BINS-000359-2019)
Checklist ItemPassedComments
- Refer to my previous note on 1/15/19 regarding hold down
locations to be verified by Ethan Hall.
FramingNO1/17/19 Framing Partial Approval - Preliminary Framing
- Garage anchor bolts are missing in areas. They do not
meet 6' oc or less spacing. Spliced bottom plate anchoring
ok.
- Check stair landings for missing joist hangers
- Bridging missing at outside box area and in middle spans.
Just recheck after trades are done.
- Complete nailing all truss bracing at gable ends and at
changes to different truss locations. Some areas are missing
nailer blocks totally and some blocks are there but are not
nailed .
- Refer to my previous note on 1/15/19 regarding hold down
locations to be verified by Ethan Hall.
Attic Access 22 x 30 minimumNO
Jack Studs HeadersNO
Continuous Header for Garage Doors withNO
Straping
Truss Specification ProvidedNO
Bracing BridgingNO
Hurricane Clips/Uplift Screws/Nail Holes FilledNO
Air Seal all Plates and SillsNO
Air Seal All Registers at FloorNO
Jan 17, 2019Page (2)
INSPECTION WORKSHEET (BINS-000359-2019)
Checklist ItemPassedComments
Air Sealing all Joints Before InsulationNO
Joist hangersNO
Jack Posts Main BeamsNO
Exterior sheeting nailed properlyNO
12 O.C.NO
Headroom 6 ft. 8 in.NO
Notches Holes Bearing WallsNO
Metal Strapping for Notches Top PlateNO
Draft stopping 1,000 sq. ft. floor trussesNO
Anchor Bolts 6 ft. or less on centerNO
Ice and water shield 24 inches from wallYES6/15/18 Ice & Water Shield Partial Approval
-Upper roof ok to shingle. I will check the balance on Monday
6/18/18
6/18/18 Ice & Water Shield Approved-Balance
Soffits-Insulation BaffelNO
Windows Habitable Space BedroomsNO
24 in. (H)NO
20 in. (W)NO
Jan 17, 2019Page (3)
INSPECTION WORKSHEET (BINS-000359-2019)
Checklist ItemPassedComments
5.7 sf above below gradeNO
5.0 sf gradeNO
Design Professional Sign-off, if requiredNO
O'Brien, John (Inspector)
Jan 17, 2019Page (4)