Loading...
Wedgewood Apts concrete test report 124 William Street, Ballston Lake, New York 12019 Phone: (518) 399-1848 Fax: (518) 399-1913 CLIENT: REPORT NUMBER: : PAGE #: 1 INSPECTION DATE: OUR FILE NUMBER:6 INSPECTOR & TEST SET: BOB BEHAN #6 ATT'N: AMBIENT WEATHER: OUR FILE LOCATION: 1 : PLACEMENT LOCATION OF LOAD # 2 : PLACEMENT LOCATION OF LOAD # 3 : 1 2 0 3 4903 / 820002 4563 / 820003 4565 / 820004 11.00 / 11.00 #11.00 / 22.00 1 11.00 / 33.00 1.767 11.40 / 11.55 0 ##11.52 / 12.11 0 12.13 / 12.32 0 12.10 / 12.30 # 12 12.35 / 1.07 ##1.10 / 1.46 1.00 MAX: 1.50 )11 0.83 0 11 1.25 0 12 1.55 1 0.40 6.25 # 0.52 6.00 1 0.13 6.00 1 WATER ADDED ONSITE (GALLONS):0.00 0 0.00 0 0.00 0 WATER ADDED AT DISCRETION OF:0.00 # 0.00 ##0.00 0.46 0.00 0.00 0.00 PLACEMENT SLUMP (INCH) (SPEC: - 5.00 )6.25 1 6.00 1 6.00 1 ENTRAINED AIR ( % VOL) (SPEC: - 7.00 ) 5.90 0 0.00 0 0.00 0381100 UNIT WEIGHT (PCF) (SPEC:-0.00 ) 144.35 0 0.00 0 0.00 0 - 90 ) 81 0 81 0 82 0 NUMBER OF TEST SPECIMEN CAST:6 0 0 0 0 174357 - 174362 0 0 0 0 0 0 1: CONCRETE SUPPLIER:CONCRETE TEST CYLINDER COMPRESSIVE RESULTS PER: ASTM: C39 P.S.I. @ 28 DAYS :UNLESS OTHERWISE NOTED ALL CYLINDERS RECEIVED: CEMENT:LBS.CYLINDER TEST UNIT CEMENT:LBS. NUMBER DATE P.S.I. GAL. COARSE AGGREGATE #1: LBS.174357 06/28/17 7 2090 X COARSE AGGREGATE #2: LBS.174358 06/28/17 7 2190 X COARSE AGGREGATE #3: LBS.174359 07/19/17 28 3420 0 FINE AGGREGATE: LBS.174360 07/19/17 28 3510 0 ADMIXTURE #1: OZS.174361 07/19/17 28 3570 0 ADMIXTURE #2: OZS.174362 01/00/00 SPARE 0 X ADMIXTURE #3: OZS. AIR ENTRAINING AGENT: OZS.0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X REPORT DISTRIBUTION:0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 01/00/00 0 0 X RESPECTFULLY SUBMITTED,0 0 0 0 01/00/00 0 0 X CONSTRUCTION TECHNOLOGY 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X TOM JOSLIN, S.E.T. (NICET)0 0 0 0 01/00/00 0 0 X MANAGER TECHNICAL SVCS.0 0 0 0 01/00/00 0 0 X PROPER HOT OR COLD WEATHER CURING PROTECTION FOR AMBIENT CONDITIONS IS AVAILABLE ONSITE. PER DRAWING: S-202, DETAIL: 5 GENERAL CONSTRUCTION PRACTICE: CONCRETE PROPERLY CONSOLIDATED. NO VISUAL EVIDENCE OF SEGREGATION OR COLD JOINTS. PLACEMENT AREA REINFORCEMENT: PLACEMENT AREA FORMWORK: ACCEPTABLE FOR ALIGNMENT & CLEANLINESS. FREE OF DEBRIS & STANDING WATER/ICE/SNOW. CLEANLINESS & COVER ACCEPTABLE. PROPERLY SIZED & LOCATED. PLACEMENT WEATHER PROTECTION: BUILDING #3: FOUNDATION WALL: SOUTHWEST SECTION BUILDING #3: FOUNDATION WALL: SOUTHEAST SECTION PLACEMENT LOCATION OF LOAD # BUILDING #3: FOUNDATION WALL: WEST CENTER SECTION 0.00 45 C O N C R E T E F I E L D I N S P E C T I O N & C O M P R E S S I O N T E S T R E S U L T S 0.00 TEST AGE 3000 0 JOINTA-GALUSHA, LLC CONTRACTOR NOTIFIED: LOAD 1,2,3: SLUMP ULTIMATE 06/22/17 4.00 0 0.0 0 0 0 0 44,050 0 0 0 0 0 0 8: 1: FILE 2: SUPPLIER 27,500 0 0 42,900 44,800 0 0 DISCREPANCIES & REMARKS: 0.0 4: 0.0 5: 6: 7: 0 0 DESIGN STRENGTH & FORMULA: 3: TIME CONC. BATCHED / ARRIVED: 26,250 DAYS UNLESS NOTED ALL TESTING IAW: ASTM: C31, C138, C143, C172, C173, C231, C470, C567, C617, C1064 DELIVERED LOAD NUMBER: TRUCK NUMBER / TICKET NUMBER: YARDAGE DELIVERED / SUBTOTAL: LAB CYLINDER CONTROL NUMBERS: WATER: CONCRETE TEMP. (F) (SPEC: SLUMP OF CONCRETE INTO PUMP: TIME PLACEMENT BEGAN / ENDED: CONCRETE AGE ( HOURS ) (SPEC: SLUMP ON ARRIVAL (INCHES): IF APPLICABLE: PROJECT: CONSTRUCTION TECHNOLOGY MR. DARREN VanDeWARKER SCHEMERHORN CONSTRUCTION, INC. 536 BAY ROAD, SUITE 2 QUEENSBURY, NEW YORK 12804 WEDGEWOOD APARTMENTS: BURKE DRIVE, QUEENSBURY, NY. Tom Joslin Tom Joslin Tom Joslin Tom Joslin APPLIED LOAD 12 06/21/17 1162.009 174357 70's: CLOUDY 4 William Street, Ballston Lake, New York 12019 Phone: (518) 399-1848 Fax: (518) 399-1913 CLIENT: REPORT NUMBER: : PAGE #: 2 INSPECTION DATE: OUR FILE NUMBER:6 INSPECTOR & TEST SET: BOB BEHAN #6 ATT'N: AMBIENT WEATHER: OUR FILE LOCATION: 4 : PLACEMENT LOCATION OF LOAD # 5 : 0 0 0 4 5 0 0 4585 / 820005 4584 / 820011 0 0 0 11.00 / 44.00 2 11.00 / 55.00 3 0.00 0 0.00 0 1.00 / 1.20 0 ##1.20 / 1.50 0 0.00 0 0.00 0 1.50 / 2.25 # 1 2.30 / 2.50 ## 0.00 0 0.00 0.00 MAX: 1.50 )1 1.42 0 1 1.50 0 0 0.00 0 0.00 5.50 2 0.20 6.25 2 0.00 0.00 0 WATER ADDED ONSITE (GALLONS):0.00 0 0.00 0 0.00 0 WATER ADDED AT DISCRETION OF:0.00 # 0.00 ##0.00 0.00 0.00 0.00 0.00 PLACEMENT SLUMP (INCH) (SPEC: - 5.00 )5.50 1 6.25 1 0.00 0 ENTRAINED AIR ( % VOL) (SPEC: - 7.00 )0.00 0 5.70 0 0.00 0038350 UNIT WEIGHT (PCF) (SPEC:-0.00 )0.00 0 145.26 0 0.00 0 - 90 ) 82 0 83 0 0 0 NUMBER OF TEST SPECIMEN CAST:0 0 6 0 0 0 0 174363 - 174368 0 0 0 1: CONCRETE SUPPLIER:CONCRETE TEST CYLINDER COMPRESSIVE RESULTS PER: ASTM: C39 P.S.I. @ 28 DAYS :UNLESS OTHERWISE NOTED ALL CYLINDERS RECEIVED: CEMENT:LBS.CYLINDER TEST UNIT CEMENT:LBS. NUMBER DATE P.S.I. GAL. COARSE AGGREGATE #1: LBS.174363 06/28/17 7 2060 X COARSE AGGREGATE #2: LBS.174364 06/28/17 7 2130 X COARSE AGGREGATE #3: LBS.174365 07/19/17 28 3320 0 FINE AGGREGATE: LBS.174366 07/19/17 28 3480 0 ADMIXTURE #1: OZS.174367 07/19/17 28 3380 0 ADMIXTURE #2: OZS.174368 01/00/00 SPARE 0 X ADMIXTURE #3: OZS. AIR ENTRAINING AGENT: OZS.0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X REPORT DISTRIBUTION:0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 01/00/00 0 0 X RESPECTFULLY SUBMITTED,0 0 0 0 01/00/00 0 0 X CONSTRUCTION TECHNOLOGY 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X TOM JOSLIN, S.E.T. (NICET)0 0 0 0 01/00/00 0 0 X MANAGER TECHNICAL SVCS.0 0 0 0 01/00/00 0 0 X Tom Joslin Tom Joslin Tom Joslin Tom Joslin APPLIED LOAD 12 06/21/17 1162.009 174363 70's: CLOUDY PROJECT: CONSTRUCTION TECHNOLOGY MR. DARREN VanDeWARKER SCHEMERHORN CONSTRUCTION, INC. 536 BAY ROAD, SUITE 2 QUEENSBURY, NEW YORK 12804 WEDGEWOOD APARTMENTS: BURKE DRIVE, QUEENSBURY, NY. IF APPLICABLE: DELIVERED LOAD NUMBER: TRUCK NUMBER / TICKET NUMBER: YARDAGE DELIVERED / SUBTOTAL: CONCRETE TEMP. (F) (SPEC: SLUMP OF CONCRETE INTO PUMP: TIME PLACEMENT BEGAN / ENDED: CONCRETE AGE ( HOURS ) (SPEC: SLUMP ON ARRIVAL (INCHES): LAB CYLINDER CONTROL NUMBERS: WATER: 0 0 DESIGN STRENGTH & FORMULA: 3: TIME CONC. BATCHED / ARRIVED: 25,900 DAYS UNLESS NOTED ALL TESTING IAW: ASTM: C31, C138, C143, C172, C173, C231, C470, C567, C617, C1064 DISCREPANCIES & REMARKS: 0.0 4: 0.0 5: 6: 7: 8: 1: FILE 2: SUPPLIER 0 0 0 43,700 26,700 0 0 41,650 42,500 0 0 0 0 0 0 0 0.0 0 0 0 0 JOINTA-GALUSHA, LLC CONTRACTOR NOTIFIED: LOAD 4,5: SLUMP ULTIMATE 06/22/17 4.00 C O N C R E T E F I E L D I N S P E C T I O N & C O M P R E S S I O N T E S T R E S U L T S 0.00 TEST AGE 3000 BUILDING #3: FOUNDATION WALL: EAST CENTER SECTION BUILDING #3: FOUNDATION WALL: NORTH SECTION PLACEMENT LOCATION OF LOAD # 0 0.00 45 PROPER HOT OR COLD WEATHER CURING PROTECTION FOR AMBIENT CONDITIONS IS AVAILABLE ONSITE. PER DRAWING: S-202, DETAIL: 5 GENERAL CONSTRUCTION PRACTICE: CONCRETE PROPERLY CONSOLIDATED. NO VISUAL EVIDENCE OF SEGREGATION OR COLD JOINTS. PLACEMENT AREA REINFORCEMENT: PLACEMENT AREA FORMWORK: ACCEPTABLE FOR ALIGNMENT & CLEANLINESS. FREE OF DEBRIS & STANDING WATER/ICE/SNOW. CLEANLINESS & COVER ACCEPTABLE. PROPERLY SIZED & LOCATED. PLACEMENT WEATHER PROTECTION: