Wedgewood Apts concrete test report 134 William Street, Ballston Lake, New York 12019 Phone: (518) 399-1848 Fax: (518) 399-1913 CLIENT: REPORT NUMBER: : PAGE #: 1 INSPECTION DATE: OUR FILE NUMBER:5 INSPECTOR & TEST SET: DAVE CASAW #5 ATT'N: AMBIENT WEATHER: OUR FILE LOCATION: 1 : PLACEMENT LOCATION OF LOAD # 2 : PLACEMENT LOCATION OF LOAD # 3 : 1 2 0 3 4585 / 820135 0 / 820136 4565 / 820137 10.00 / 10.00 4 10.00 / 20.00 4 10.00 / 30.00 4.45 2.35 / 2.55 0 ##2.42 / 2.57 0 3.25 / 3.45 0 3.15 / 3.45 # 3 3.45 / 4.05 ##4.08 / 4.27 4.00 MAX: 1.50 )2 1.17 0 2 1.38 0 3 1.03 0 0.35 5.00 3 0.42 4.75 4 0.25 5.00 4 WATER ADDED ONSITE (GALLONS):0.00 0 0.00 0 0.00 0 WATER ADDED AT DISCRETION OF:0.00 # 0.00 ##0.00 0.27 0.00 0.00 0.00 PLACEMENT SLUMP (INCH) (SPEC: - 5.00 ) 5.00 0 4.75 0 5.00 0 ENTRAINED AIR ( % VOL) (SPEC: - 7.00 )0.00 0 5.00 0 0.00 0038040 UNIT WEIGHT (PCF) (SPEC:-0.00 )0.00 0 144.08 0 0.00 0 - 90 ) 70 0 70 0 70 0 NUMBER OF TEST SPECIMEN CAST:0 0 6 0 0 0 0 174549 - 174554 0 0 0 0 CONCRETE SUPPLIER:CONCRETE TEST CYLINDER COMPRESSIVE RESULTS PER: ASTM: C39 P.S.I. @ 28 DAYS :UNLESS OTHERWISE NOTED ALL CYLINDERS RECEIVED: CEMENT:LBS.CYLINDER TEST UNIT CEMENT:LBS. NUMBER DATE P.S.I. GAL. COARSE AGGREGATE #1: LBS.174549 07/04/17 7 3230 0 COARSE AGGREGATE #2: LBS.174550 07/04/17 7 3100 0 COARSE AGGREGATE #3: LBS.174551 07/25/17 28 4310 0 FINE AGGREGATE: LBS.174552 07/25/17 28 4440 0 ADMIXTURE #1: OZS.174553 07/25/17 28 4550 0 ADMIXTURE #2: OZS.174554 01/00/00 SPARE 0 X ADMIXTURE #3: OZS. AIR ENTRAINING AGENT: OZS.0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X REPORT DISTRIBUTION:0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 01/00/00 0 0 X RESPECTFULLY SUBMITTED,0 0 0 0 01/00/00 0 0 X CONSTRUCTION TECHNOLOGY 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X TOM JOSLIN, S.E.T. (NICET)0 0 0 0 01/00/00 0 0 X MANAGER TECHNICAL SVCS.0 0 0 0 01/00/00 0 0 X Tom Joslin Tom Joslin Tom Joslin Tom Joslin APPLIED LOAD 13 06/27/17 1162.009 174549 60's: P. CLOUDY PROJECT: CONSTRUCTION TECHNOLOGY MR. DARREN VanDeWARKER SCHEMERHORN CONSTRUCTION, INC. 536 BAY ROAD, SUITE 2 QUEENSBURY, NEW YORK 12804 WEDGEWOOD APARTMENTS: BURKE DRIVE, QUEENSBURY, NY. IF APPLICABLE: DELIVERED LOAD NUMBER: TRUCK NUMBER / TICKET NUMBER: YARDAGE DELIVERED / SUBTOTAL: CONCRETE TEMP. (F) (SPEC: SLUMP OF CONCRETE INTO PUMP: TIME PLACEMENT BEGAN / ENDED: CONCRETE AGE ( HOURS ) (SPEC: SLUMP ON ARRIVAL (INCHES): LAB CYLINDER CONTROL NUMBERS: WATER: 0 0 DESIGN STRENGTH & FORMULA: 3: TIME CONC. BATCHED / ARRIVED: 40,600 DAYS UNLESS NOTED ALL TESTING IAW: ASTM: C31, C138, C143, C172, C173, C231, C470, C567, C617, C1064 DISCREPANCIES & REMARKS: 0.0 4: 0.0 5: 6: 7: 8: 1: FILE 2: SUPPLIER 0 0 0 55,750 38,950 0 0 54,100 57,150 0 0 0 0 0 0 0 0.0 0 0 0 0 JOINTA-GALUSHA, LLC 0 ULTIMATE 06/28/17 4.00 C O N C R E T E F I E L D I N S P E C T I O N & C O M P R E S S I O N T E S T R E S U L T S 0.00 TEST AGE 3000 BUILDING #1: FOUNDATION WALL: EAST INTERIOR WALL; NORTH WALL, EAST THIRD; EAST WALL, NORTH HALF BUILDING #1: FOUNDATION WALL: EAST WALL; SOUTH HALF; SOUTH WALL, EAST HALF PLACEMENT LOCATION OF LOAD # BUILDING #1: FOUNDATION WALL: WEST INTERIOR WALL; NORTH WALL, CENTER THIRD 0.00 45 PROPER HOT OR COLD WEATHER CURING PROTECTION FOR AMBIENT CONDITIONS IS AVAILABLE ONSITE. PER DRAWING: S-202, DETAIL: 5 GENERAL CONSTRUCTION PRACTICE: CONCRETE PROPERLY CONSOLIDATED. NO VISUAL EVIDENCE OF SEGREGATION OR COLD JOINTS. PLACEMENT AREA REINFORCEMENT: PLACEMENT AREA FORMWORK: ACCEPTABLE FOR ALIGNMENT & CLEANLINESS. FREE OF DEBRIS & STANDING WATER/ICE/SNOW. CLEANLINESS & COVER ACCEPTABLE. PROPERLY SIZED & LOCATED. PLACEMENT WEATHER PROTECTION: 4 William Street, Ballston Lake, New York 12019 Phone: (518) 399-1848 Fax: (518) 399-1913 CLIENT: REPORT NUMBER: : PAGE #: 2 INSPECTION DATE: OUR FILE NUMBER:5 INSPECTOR & TEST SET: DAVE CASAW #5 ATT'N: AMBIENT WEATHER: OUR FILE LOCATION: 4 : PLACEMENT LOCATION OF LOAD # 5 : 0 0 0 4 5 0 0 4905 / 820138 4585 / 820139 0 0 0 10.00 / 40.00 5 10.00 / 50.00 5 0.00 0 0.00 0 4.15 / 4.32 0 ##4.45 / 5.00 0 0.00 0 0.00 0 4.37 / 4.59 # 5 5.01 / 5.20 ## 0.00 0 0.00 0.00 MAX: 1.50 )4 0.73 0 4 0.58 0 0 0.00 0 0.15 4.75 4 0.45 5.00 5 0.00 0.00 0 WATER ADDED ONSITE (GALLONS):0.00 0 0.00 0 0.00 0 WATER ADDED AT DISCRETION OF:0.00 # 0.00 ##0.00 0.00 0.00 0.00 0.00 PLACEMENT SLUMP (INCH) (SPEC: - 5.00 ) 4.75 0 5.00 0 0.00 0 ENTRAINED AIR ( % VOL) (SPEC: - 7.00 )0.00 0 5.60 0 0.00 0037900 UNIT WEIGHT (PCF) (SPEC:-0.00 )0.00 0 143.55 0 0.00 0 - 90 ) 71 0 70 0 0 0 NUMBER OF TEST SPECIMEN CAST:0 0 6 0 0 0 0 174555 - 174560 0 0 0 0 CONCRETE SUPPLIER:CONCRETE TEST CYLINDER COMPRESSIVE RESULTS PER: ASTM: C39 P.S.I. @ 28 DAYS :UNLESS OTHERWISE NOTED ALL CYLINDERS RECEIVED: CEMENT:LBS.CYLINDER TEST UNIT CEMENT:LBS. NUMBER DATE P.S.I. GAL. COARSE AGGREGATE #1: LBS.174555 07/04/17 7 2870 X COARSE AGGREGATE #2: LBS.174556 07/04/17 7 2830 X COARSE AGGREGATE #3: LBS.174557 07/25/17 28 3960 0 FINE AGGREGATE: LBS.174558 07/25/17 28 4160 0 ADMIXTURE #1: OZS.174559 07/25/17 28 4050 0 ADMIXTURE #2: OZS.174560 01/00/00 SPARE 0 X ADMIXTURE #3: OZS. AIR ENTRAINING AGENT: OZS.0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X REPORT DISTRIBUTION:0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 01/00/00 0 0 X RESPECTFULLY SUBMITTED,0 0 0 0 01/00/00 0 0 X CONSTRUCTION TECHNOLOGY 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X TOM JOSLIN, S.E.T. (NICET)0 0 0 0 01/00/00 0 0 X MANAGER TECHNICAL SVCS.0 0 0 0 01/00/00 0 0 X PROPER HOT OR COLD WEATHER CURING PROTECTION FOR AMBIENT CONDITIONS IS AVAILABLE ONSITE. PER DRAWING: S-202, DETAIL: 5 GENERAL CONSTRUCTION PRACTICE: CONCRETE PROPERLY CONSOLIDATED. NO VISUAL EVIDENCE OF SEGREGATION OR COLD JOINTS. PLACEMENT AREA REINFORCEMENT: PLACEMENT AREA FORMWORK: ACCEPTABLE FOR ALIGNMENT & CLEANLINESS. FREE OF DEBRIS & STANDING WATER/ICE/SNOW. CLEANLINESS & COVER ACCEPTABLE. PROPERLY SIZED & LOCATED. PLACEMENT WEATHER PROTECTION: BUILDING #1: FOUNDATION WALL: SOUTH WALL, WEST HALF; WEST WALL, SOUTH HALF BUILDING #1: FOUNDATION WALL: WEST WALL, NORTH HALF; NORTH WALL, WEST THIRD PLACEMENT LOCATION OF LOAD # 0 0.00 45 C O N C R E T E F I E L D I N S P E C T I O N & C O M P R E S S I O N T E S T R E S U L T S 0.00 TEST AGE 3000 0 JOINTA-GALUSHA, LLC 0 ULTIMATE 06/28/17 4.00 0 0.0 0 0 0 0 52,300 0 0 0 0 0 0 8: 1: FILE 2: SUPPLIER 35,550 0 0 49,800 50,900 0 0 DISCREPANCIES & REMARKS: 0.0 4: 0.0 5: 6: 7: 0 0 DESIGN STRENGTH & FORMULA: 3: TIME CONC. BATCHED / ARRIVED: 36,100 DAYS UNLESS NOTED ALL TESTING IAW: ASTM: C31, C138, C143, C172, C173, C231, C470, C567, C617, C1064 DELIVERED LOAD NUMBER: TRUCK NUMBER / TICKET NUMBER: YARDAGE DELIVERED / SUBTOTAL: LAB CYLINDER CONTROL NUMBERS: WATER: CONCRETE TEMP. (F) (SPEC: SLUMP OF CONCRETE INTO PUMP: TIME PLACEMENT BEGAN / ENDED: CONCRETE AGE ( HOURS ) (SPEC: SLUMP ON ARRIVAL (INCHES): IF APPLICABLE: PROJECT: CONSTRUCTION TECHNOLOGY MR. DARREN VanDeWARKER SCHEMERHORN CONSTRUCTION, INC. 536 BAY ROAD, SUITE 2 QUEENSBURY, NEW YORK 12804 WEDGEWOOD APARTMENTS: BURKE DRIVE, QUEENSBURY, NY. Tom Joslin Tom Joslin Tom Joslin Tom Joslin APPLIED LOAD 13 06/27/17 1162.009 174555 60's: P. CLOUDY