Wedgewood Apts concrete test report 164 William Street, Ballston Lake, New York 12019 Phone: (518) 399-1848 Fax: (518) 399-1913 CLIENT: REPORT NUMBER: : PAGE #: 1 INSPECTION DATE: OUR FILE NUMBER:6 INSPECTOR & TEST SET: BOB BEHAN #6 ATT'N: AMBIENT WEATHER: OUR FILE LOCATION: 1 : PLACEMENT LOCATION OF LOAD # 2 : PLACEMENT LOCATION OF LOAD # 3 : 1 2 0 3 4561 / 820472 4905 / 820473 4560 / 820474 11.00 / 11.00 2 11.00 / 22.00 3 11.00 / 33.00 3.683 1.15 / 1.35 0 ##1.46 / 2.03 0 2.22 / 2.36 0 1.41 / 2.06 # 2 2.09 / 2.43 ##2.45 / 3.41 3.00 MAX: 1.50 )1 0.85 0 1 0.95 0 2 1.32 0 0.15 6.00 2 0.46 5.50 2 0.22 5.50 3 WATER ADDED ONSITE (GALLONS):0.00 0 0.00 0 0.00 0 WATER ADDED AT DISCRETION OF:0.00 # 0.00 ##0.00 0.41 0.00 0.00 0.00 PLACEMENT SLUMP (INCH) (SPEC: - 5.00 )6.00 1 5.50 1 5.50 1 ENTRAINED AIR ( % VOL) (SPEC: - 7.00 ) 5.20 0 0.00 0 0.00 0368400 UNIT WEIGHT (PCF) (SPEC:-0.00 ) 139.54 0 0.00 0 0.00 0 - 90 ) 82 0 82 0 82 0 NUMBER OF TEST SPECIMEN CAST:6 0 0 0 0 175068 - 175073 0 0 0 0 0 0 1: CONCRETE SUPPLIER:CONCRETE TEST CYLINDER COMPRESSIVE RESULTS PER: ASTM: C39 P.S.I. @ 28 DAYS :UNLESS OTHERWISE NOTED ALL CYLINDERS RECEIVED: CEMENT:LBS.CYLINDER TEST UNIT CEMENT:LBS. NUMBER DATE P.S.I. GAL. COARSE AGGREGATE #1: LBS.175068 07/24/17 7 3010 0 COARSE AGGREGATE #2: LBS.175069 07/24/17 7 2900 X COARSE AGGREGATE #3: LBS.175070 08/14/17 28 4070 0 FINE AGGREGATE: LBS.175071 08/14/17 28 3790 0 ADMIXTURE #1: OZS.175072 08/14/17 28 3890 0 ADMIXTURE #2: OZS.175073 01/00/00 SPARE 0 X ADMIXTURE #3: OZS. AIR ENTRAINING AGENT: OZS.0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X REPORT DISTRIBUTION:0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 01/00/00 0 0 X RESPECTFULLY SUBMITTED,0 0 0 0 01/00/00 0 0 X CONSTRUCTION TECHNOLOGY 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X TOM JOSLIN, S.E.T. (NICET)0 0 0 0 01/00/00 0 0 X MANAGER TECHNICAL SVCS.0 0 0 0 01/00/00 0 0 X PROPER HOT OR COLD WEATHER CURING PROTECTION FOR AMBIENT CONDITIONS IS AVAILABLE ONSITE. PER DRAWING: S-202, DETAIL: 5 GENERAL CONSTRUCTION PRACTICE: CONCRETE PROPERLY CONSOLIDATED. NO VISUAL EVIDENCE OF SEGREGATION OR COLD JOINTS. PLACEMENT AREA REINFORCEMENT: PLACEMENT AREA FORMWORK: ACCEPTABLE FOR ALIGNMENT & CLEANLINESS. FREE OF DEBRIS & STANDING WATER/ICE/SNOW. CLEANLINESS & COVER ACCEPTABLE. PROPERLY SIZED & LOCATED. PLACEMENT WEATHER PROTECTION: BUILDING #4: FOUNDATION WALL: SOUTH SECTION: EAST HALF BUILDING #4: FOUNDATION WALL: SOUTH SECTION: WEST HALF PLACEMENT LOCATION OF LOAD # BUILDING #4: FOUNDATION WALL: NORTH SECTION: SOUTH WALL; EAST WALL 0.00 45 C O N C R E T E F I E L D I N S P E C T I O N & C O M P R E S S I O N T E S T R E S U L T S 0.00 TEST AGE 3000 0 JOINTA-GALUSHA, LLC CONTRACTOR NOTIFIED: LOAD 1,2,3: SLUMP ULTIMATE 07/18/17 4.00 0 0.0 0 0 0 0 47,650 0 0 0 0 0 0 8: 1: FILE 2: SUPPLIER 36,400 0 0 51,100 48,900 0 0 DISCREPANCIES & REMARKS: 0.0 4: 0.0 5: 6: 7: 0 0 DESIGN STRENGTH & FORMULA: 3: TIME CONC. BATCHED / ARRIVED: 37,750 DAYS UNLESS NOTED ALL TESTING IAW: ASTM: C31, C138, C143, C172, C173, C231, C470, C567, C617, C1064 DELIVERED LOAD NUMBER: TRUCK NUMBER / TICKET NUMBER: YARDAGE DELIVERED / SUBTOTAL: LAB CYLINDER CONTROL NUMBERS: WATER: CONCRETE TEMP. (F) (SPEC: SLUMP OF CONCRETE INTO PUMP: TIME PLACEMENT BEGAN / ENDED: CONCRETE AGE ( HOURS ) (SPEC: SLUMP ON ARRIVAL (INCHES): IF APPLICABLE: PROJECT: CONSTRUCTION TECHNOLOGY MR. DARREN VanDeWARKER SCHEMERHORN CONSTRUCTION, INC. 536 BAY ROAD, SUITE 2 QUEENSBURY, NEW YORK 12804 WEDGEWOOD APARTMENTS: BURKE DRIVE, QUEENSBURY, NY. Tom Joslin Tom Joslin Tom Joslin Tom Joslin APPLIED LOAD 16 07/17/17 1162.009 175068 80's: P' CLOUDY 4 William Street, Ballston Lake, New York 12019 Phone: (518) 399-1848 Fax: (518) 399-1913 CLIENT: REPORT NUMBER: : PAGE #: 2 INSPECTION DATE: OUR FILE NUMBER:6 INSPECTOR & TEST SET: BOB BEHAN #6 ATT'N: AMBIENT WEATHER: OUR FILE LOCATION: 4 : PLACEMENT LOCATION OF LOAD # 5 : 0 0 0 4 5 0 0 4561 / 820475 4588 / 820476 0 0 0 10.00 / 43.00 4 10.00 / 53.00 5 0.00 0 0.00 0 3.00 / 3.25 0 ##3.25 / 3.45 0 0.00 0 0.00 0 3.44 / 4.15 # 3 4.19 / 4.48 ## 0.00 0 0.00 0.00 MAX: 1.50 )3 1.25 0 3 1.38 0 0 0.00 0 0.00 5.75 4 0.25 5.75 4 0.00 0.00 0 WATER ADDED ONSITE (GALLONS):0.00 0 0.00 0 0.00 0 WATER ADDED AT DISCRETION OF:0.00 # 0.00 ##0.00 0.00 0.00 0.00 0.00 PLACEMENT SLUMP (INCH) (SPEC: - 5.00 )5.75 1 5.75 1 0.00 0 ENTRAINED AIR ( % VOL) (SPEC: - 7.00 )0.00 0 5.50 0 0.00 0037000 UNIT WEIGHT (PCF) (SPEC:-0.00 )0.00 0 140.14 0 0.00 0 - 90 ) 81 0 81 0 0 0 NUMBER OF TEST SPECIMEN CAST:0 0 6 0 0 0 0 175074 - 175079 0 0 0 1: CONCRETE SUPPLIER:CONCRETE TEST CYLINDER COMPRESSIVE RESULTS PER: ASTM: C39 P.S.I. @ 28 DAYS :UNLESS OTHERWISE NOTED ALL CYLINDERS RECEIVED: CEMENT:LBS.CYLINDER TEST UNIT CEMENT:LBS. NUMBER DATE P.S.I. GAL. COARSE AGGREGATE #1: LBS.175074 07/24/17 7 2560 X COARSE AGGREGATE #2: LBS.175075 07/24/17 7 2440 X COARSE AGGREGATE #3: LBS.175076 08/14/17 28 3360 0 FINE AGGREGATE: LBS.175077 08/14/17 28 3480 0 ADMIXTURE #1: OZS.175078 08/14/17 28 3320 0 ADMIXTURE #2: OZS.175079 01/00/00 SPARE 0 X ADMIXTURE #3: OZS. AIR ENTRAINING AGENT: OZS.0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X REPORT DISTRIBUTION:0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X 0 0 0 01/00/00 0 0 X RESPECTFULLY SUBMITTED,0 0 0 0 01/00/00 0 0 X CONSTRUCTION TECHNOLOGY 0 0 0 0 01/00/00 0 0 X 0 0 0 0 01/00/00 0 0 X TOM JOSLIN, S.E.T. (NICET)0 0 0 0 01/00/00 0 0 X MANAGER TECHNICAL SVCS.0 0 0 0 01/00/00 0 0 X Tom Joslin Tom Joslin Tom Joslin Tom Joslin APPLIED LOAD 16 07/17/17 1162.009 175074 80's: P' CLOUDY PROJECT: CONSTRUCTION TECHNOLOGY MR. DARREN VanDeWARKER SCHEMERHORN CONSTRUCTION, INC. 536 BAY ROAD, SUITE 2 QUEENSBURY, NEW YORK 12804 WEDGEWOOD APARTMENTS: BURKE DRIVE, QUEENSBURY, NY. IF APPLICABLE: DELIVERED LOAD NUMBER: TRUCK NUMBER / TICKET NUMBER: YARDAGE DELIVERED / SUBTOTAL: CONCRETE TEMP. (F) (SPEC: SLUMP OF CONCRETE INTO PUMP: TIME PLACEMENT BEGAN / ENDED: CONCRETE AGE ( HOURS ) (SPEC: SLUMP ON ARRIVAL (INCHES): LAB CYLINDER CONTROL NUMBERS: WATER: 0 0 DESIGN STRENGTH & FORMULA: 3: TIME CONC. BATCHED / ARRIVED: 32,100 DAYS UNLESS NOTED ALL TESTING IAW: ASTM: C31, C138, C143, C172, C173, C231, C470, C567, C617, C1064 DISCREPANCIES & REMARKS: 0.0 4: 0.0 5: 6: 7: 8: 1: FILE 2: SUPPLIER 0 0 0 43,700 30,600 0 0 42,150 41,650 0 0 0 0 0 0 0 0.0 0 0 0 0 JOINTA-GALUSHA, LLC CONTRACTOR NOTIFIED: LOAD 4,5: SLUMP ULTIMATE 07/18/17 4.00 C O N C R E T E F I E L D I N S P E C T I O N & C O M P R E S S I O N T E S T R E S U L T S 0.00 TEST AGE 3000 BUILDING #4: FOUNDATION WALL: NORTH SECTION: NORTH WALL; NORTH WALL BUILDING #4: FOUNDATION WALL: NORTH SECTION: WEST WALL PLACEMENT LOCATION OF LOAD # 0 0.00 45 PROPER HOT OR COLD WEATHER CURING PROTECTION FOR AMBIENT CONDITIONS IS AVAILABLE ONSITE. PER DRAWING: S-202, DETAIL: 5 GENERAL CONSTRUCTION PRACTICE: CONCRETE PROPERLY CONSOLIDATED. NO VISUAL EVIDENCE OF SEGREGATION OR COLD JOINTS. PLACEMENT AREA REINFORCEMENT: PLACEMENT AREA FORMWORK: ACCEPTABLE FOR ALIGNMENT & CLEANLINESS. FREE OF DEBRIS & STANDING WATER/ICE/SNOW. CLEANLINESS & COVER ACCEPTABLE. PROPERLY SIZED & LOCATED. PLACEMENT WEATHER PROTECTION: