Loading...
ComCheck COMcheck Software version 4.0.2.2 Envelope Compliance Certificate FILE COPY Project Information Energy Code: 2014 New York Energy Conservation Construction Code Project Title: Wedgewood Apartments Location: Warren County, New York 302.91-28.1 CC-000362-2016 Climate Zone: 6a Project Type: New Construction Schermerhorn Wedgewood LLC Vertical Glazing I Wall Area: 12% 8-28 Wedgewood Drive, Btdg• #2 8-unit apt. 9782 0., garage 2288 S.f. Construction Site: Owner/Agent: Designer/Contractor: Burke Drive Schermerhorn Properties, Inc. Ethan P. Hall Queensbury, NY 12804 536 Bay Road Rucinski Hall Architecture Suite 2 134 Dix Ave Queensbury, NY 12804 Glens Falls, NY 12801 518-798-0674 518-741-0268 rich@5chermerhornproperties.com ephall@nycap.rr.com Building Area Floor Area 1-Multifamily:Residential 9782 Additional Efficiency Package JUN 14 2016 Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor FactortaF Perimeter Roof 1:Attic Roof with Wood Joists,[Bldg.Use 1 -Multifamily] 4832 3B.0 0.0 0.027 0.021 Exterior Wall 1:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Multifamily] 1593 19.0 3.6 0.052 0.051 Window 1:Vinyl]Fiberglass Frame:Operable,Perf,Specs.:Product ID 62 - - 0.320 0.430 product label,SHGC 0.35,[Bldg.Use 1 -Multifamily](b) Door 1:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 --- --- 0.300 0.370 Door 2:Insulated Metal,Swinging,[Bldg. Use 1-Multifamily] 20 - - 0.300 0.370 Door 3:Insulated Metal,Swinging,[Bldg.Use 1-Multifamily] 20 --- - 0.300 0.370 Door 4:Insulated Metal,Swinging,[Bldg.Use 1 -Multifamily] 20 - - 0.300 0.370 Door 5:Insulated Metal,Swinging,[Bldg.Use 1 -Multifamily] 20 - - 0.300 0.370 Door 6:insulated Metal,Swinging,[Bldg.Use 1 -Multifamily] 20 0.300 0.370 Door 7:Insulated Metal,Swinging,[Bldg.Use 1 -Multifamily] 20 - - 0.300 0.370 Door 8:Insulated Metal,Swinging,[Bldg.Use 1 -Multifamily] 20 - - 0.300 0.370 Door 9:Insulated Metal,Swinging,[Bldg.Use 1 -Multifamily] 20 - - 0.300 0.370 Door 10:Insulated Metal,Swinging,[Bldg.Use 1 -Multifamily] 20 - v 0.300 0.370 Door 11:insulated Metal,Swinging,[Bldg.Use 1 -Multifamily] 20 - - 0.300 0.370 Door 12:Insulated Metal,Swinging, [Bldg.Use i -Multifamily] 20 -- - 0.300 0.370 Door 13:Insulated Metal,Swinging,[Bldg.Use 1 -Multifamily] 20 - 0.300 0.370 Door 14:Insulated Metal,Swinging,(Bldg.Use 1 -Multifamily] 20 - - 0.300 0.370 Exterior Wall 2:Wood-Framed,16"o.c.,[Bldg.Use 1 -Multifamily] 461 19.0 3.6 0.052 0.051 Door 15:Insulated Metal,Swinging,[Bldg.Use 1 -Multifamily] 20 - - 0.300 0.370 Exterior Wall 3:Wood-Framed,16"o.c.,[Bldg.Use 1 -Multifamily] 190 19.0 3.6 0.052 0.051 Exterior Wail 4:Wood-Framed, 16`o.c.,[Bldg.Use 1 -Multifamily] 1593 19.0 3.6 0.052 0.051 Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: Y:ISchermerhorn\Wedgewood Apartments\Wedgewood Apartments.cck Page 1 of 20 Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Facton.) Perimeter Window 2:Vinyl/Fiberglass Frame:Operable,Perf.Specs.:Product ID 186 - - 0.320 0.430 product label,SHGC 0.35,[Bldg.Use 1-Multifamily](b) Door 16:Glass(>50%glazing):Nonmetal Frame,Non-Entrance Door, 40 - - 0.320 0.770 Perf.Specs.:Product ID product label.SHGC 0.35,[Bldg.Use 1 - Multifamily](b) Door 17:Glass(>50%glazing):Nonmetal Frame,Non-Entrance Door, 40 - - 0.320 0.770 Perf.Specs.:Product ID product label,SHGC 0.35,[Bldg.Use 1 - Multifamily](b) Door 18:Glass(>50%glazing):Nonmetal Frame,Non-Entrance Door, 40 - - 0.320 0.770 Pert.Specs.:Product ID product label,SHGC 0.35,[Bldg.Use 1- Multifamily](b) Door 19:Glass(>50%glazing):Nonmetal Frame,Non-Entrance Door, 40 - - 0.320 0.770 Pert.Specs.:Product ID product label,SHGC 0.35,[Bldg.Use 1 - Multifamily](b) Door 20:Glass(>50%glazing):Nonmetal Frame,Non-Entrance Door, 40 - - 0.320 0.770 Perf.Specs.:Product ID product label,SHGC 0.35,[Bldg.Use 1 - Multifamily](b) Door 21:Glass(>50%glazing):Nonmetal Frame,Non-Entrance Door, 40 - -- 0.320 0,770 Perf.Specs.:Product ID product label,SHGC 0.35,[Bldg.Use 1- Multifamily](b) Exterior Wall 5:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Multifamily] 461 19.0 3.6 0.052 0.051 Door 22:Insulated Metal,Swinging,[Bldg.Use 1 -Multifamily] 20 - - 0.300 0.370 Exterior Wall 6:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Multifamily] 190 19.0 3.6 0.052 0.051 Exterior Wall 7:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Multifamily] 1294 19.0 3.6 0.052 0.051 Window 3:Vinyl/Fiberglass Frame:Operable,Perf.Specs.:Product 1D 54 -- --- 0.320 0.430 product label,SHGC 0.35,[Bldg.Use 1 -Multifamily](b) Window 4:Vinyl/Fiberglass Frame:Operable,Perf.Specs.:Product 1D 62 --- - 0.320 0.430 product label,SHGC 0.35,[Bldg.Use 1 -Multifamily](b) Exterior Wall 8:Wood-Framed,16"o.c.,[Bldg.Use 1 -Multifamily] 415 19.0 3.6 0.052 0.051 Exterior Wall 9:Wood-Framed,16°o.c.,[Bldg.Use 1-Multifamily] 171 19.0 3.6 0.052 0.051 Exterior Wall 10:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Multifamily] 1294 19.0 3.6 0.052 0.051 Window 5:Vinyl/Fiberglass Frame:Operable,Perf.Specs.:Product ID 310 - - 0.320 0.430 product label,SHGC 0.35,.[Bldg.Use 1 -Multifamily](b) Door 23:Glass(>50%glazing):Nonmetal Frame,Non-Entrance Door, 40 - - 0.320 0.770 Perf.Specs.:Product ID product label,SHGG 0.35,[Bldg. Use 1 - Multifamily](b) Door 24:Glass(>50%glazing):Nonmetal Frame,Non-Entrance Door, 40 - - 0.320 0.770 Pert.Specs.:Product ID product label,SHGC 0.35,[Bldg.Use 1 - Multifamily](b) Exterior Wall 11:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Multifamily] 415 19.0 3.6 0.052 0.051 Exterior Wall 12:Wood-Framed, 16"o.c.,[Bldg.Use 1 -Multifamily] 171 19.0 3.6 0.052 0.051 Floor 1:Slab-On-Grade:Unheated,Vertical 4 ft.,[Bldg.Use 1 - 449 - 10.0 0.495 0.520 Multifamily](c) (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. (b)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (c)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. r code Envelope PASSES: Design 3% bette than RA Envelope Compliance Statement Compliance Statement. The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed envelope systems have been designed to meet the 2014 New York Energy Conservation Construction Code requirements in COMcheck Version 4.0.2.2 and to comply with the mandatory requirements listed in the Inspection Checklist. Project Title: Wedgewood Apartments Report date: 11/03/15 Data fiiename: Y:15chermerhorn\Wedgewood Apartments\Wedgewood Apartments.cck Page 2 of 20 Ethan P. Hal! Architect : ...,,. Name-Title Sig r r� ��.��ryY�. ,�y, Date 704N Project Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: Y:15chermerhorn\Wedgewood Apartments\Wedgewood Apartments.cck Page 3 of 20 . CQMcheck Software Version 4.0.2,2 Y interior Lighting Compliance Certificate Project Information Energy Code: 2014 New York Energy Conservation Construction Code Project Title: Wedgewood Apartments Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: Burke Drive Schermerhorn Properties, Inc. Ethan P. Hall Queensbury, NY 12804 535 Bay Road Rucinski Hall Architecture Suite 2 134 Dix Ave Queensbury, NY 12804 Glens Falls, NY 12801 518-798-0674 518-741-0268 rich@schermerhornproperties.com ephall@nycap.rr.com Additional Efficiency Package Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts 1 ft2 (B X C) 1-Multifamily 9782 0.60 5869 Total Allowed Watts= 5869 Proposed Interior Lighting Power A B C D E Fixture ID: Description/Lamp I Wattage Per Lamp I Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. 1-Multifamily Compact Fluorescent 1:Spiral 23W: Electronic: f 108 32 3456 Total Proposed Watts= 3456 Interior Lighting Design better than code Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this dccument is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2014 New York Energy Conservation Construction Code requirements in COMcheck Version 4.0.2.2 and to comply with the mandatory requirements listed in the InspgCVn Che list. Ethan P. Hall-Architect rl' /4- JU Ar-- Name-Title SWature Date Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: Y:ISchermerhorn\Wedgewood Apartments\Wedgewood Apartments,cck Page 4 of 20 C©Mcheck Software Version 4.0.2.2 Exterior Lighting Compliance Certificate Project Information Energy Code: 2014 New York Energy Conservation Construction Code Project Title: Wedgewood Apartments Project Type: New Construction Exterior Lighting Zone 2(Residential mixed use area) Construction Site: Owner/Agent: DesignerlContractor: Burke Drive Schermerhorn Properties, Inc. Ethan P. Hall Queensbury, NY 12804 536 Bay Road Rucinski Ball Architecture Suite 2 134 Dix Ave Queensbury, NY 12804 Glens Falls, NY 12801 518-798-0674 518-741-0268 rich@schermerhornproperties.com ephall@nycap.rr.com Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts I Unit Wattage (B X C) Entry canopy 8 ft2 0.25 Yes 2 Total Tradable Watts(a)= 2 Total Allowed Watts= 2 Total Allowad Supplemental Watts(b)= 604 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID : Description 1 Lamp I Wattage Per Lamp 1 Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Entry canopy(8 ft2):Tradable Wattage Compact Fluorescent 1:Spiral 23W:Electronic: 1 16 32 512 Total Tradable Proposed Watts= 512 Exterior Lighting P c better than code Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed exterior lighting systems have been designed to meet the 2014 New York Energy Conservation Construction Code r_aguirWents in COMcheck Version 4.0.2.2 and to comply with the mandatory requirements listed in the Insp r n C /J Ethan P. Hall-Architect he t '0JIfit alk Name-Title 4reafure Date Project Title: Wedgewood Apartments Report date: 11103/15 Data filename: Y:1Schermerhorn\Wedgewood Apartments\Wedgewood Apartments.cck Page 5 of 20 COMcheck Software Version 4.0.2,2 Mechanical Compliance Certificate Project Information Energy Code: 2014 New York Energy Conservation Construction Code Project Title: Wedgewood Apartments Location: Warren County,New York Climate Zone: 6a Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor Burke Drive Schermerhom Properties,Inc. Ethan P.Hall Queensbury,NY 12804 536 Bay Road Rucinski Hall Architecture Suite 2 134 Dix Ave Queensbury,NY 12804 Glens Falls,NY 12801 518-798-0674 518-741-0268 rich@schermerhomproperties.com ephall@nycap.rr.com Additional Efficiency Package Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Mechanical Systems List Quantity System Type&Description 1 HVAC System 1(Single Zone): Heating:1 each-Central Furnace,Gas,Capacity=45 kBtu/h Proposed Efficiency=93.00%Et,Required Efficiency=80.00%Et Cooling:1 each-Packaged Terminal Unit,Capacity=15 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=13.00 EER,Required Efficiency=9.30 EER Fan System: FAN SYSTEM 1—Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Constant Volume,175 CFM,0.5 motor nameplate hp 1 Water Heater 1: Electric Storage Water Heater,Capacity:0 gallons w/Circulation Pump No minimum efficiency requirement applies Mechanical Compliance Statement Comp/Nance Statement: The proposed mechanical design represented in this document is consistent with the building pians, specifications,and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2014 New York Energy Conservation Consction Cod qu' ments in COMcheck Version 4.0.2.2 and to comply with the mandatory requirements listed in theAlnspn�T�Ch�Ethan P.Hall-Architect 14Vu��Name-Title Date Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: Y:\Schermerhonn\Wedgewood Apartments\Wedgewood Apartments.cck Page 6 of 20 iCOMcheck Software Version 4.0.2.2 Inspection Checklist Energy Code: 2014 New York Energy Conservation Construction Code Requirements: 100.0%were addressed directly in the COMcheck software Text in the"Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen.For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan ReviewCompiles3 Comments/Assumptions &Re .ID C103.2 Plans and/or specifications provide all ❑Complies Requirement will be met. [PRI]' information with which compliance ❑Does Not can be determined for the building []Not Observable Location on plans/spec:A-1 envelope and document where exceptions to the standard are ❑Not Applicable claimed. C103.2 Plans,specifications,and/or ❑Complies Requirement will be met. [PR2]1 calculations provide all information ❑Does Not with which compliance can be []Not Observable Location on plans/spec:A-1 determined for the mechanical systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed.Load calculations per acceptable engineering standards and handbooks. C103.2 Plans,specifications,and/or ❑Complies Requirement will be met. [PR3]1 calculations provide all information '❑Does Not .with which compliance can be []Not Observable Location on plans/spec:A-1 determined for the service water heating systems and equipment and ❑Not Applicable document where exceptions to the 'standard are claimed.Hot water system sized per manufacturer's sizing guide. 0103.2 Plans,specifications,and/or [ Complies Requirement will be met. [PR4]1 calculations provide all information [ Does Not with which compliance can be .❑Not Observable Location on plans/spec:A-1 determined for the interior lighting and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed.Information provided should include interior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. C103.2 Plans,specifications,and/or ❑Complies Requirement will be met. [PR8]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable,Location on plans/spec:A-1 determined for the exterior lighting and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed.Information provided should include exterior lighting power calculations,wattage of bulbs and ballasts,transformers and control devices. C406 Plans,specifications,and/or [ Complies Requirement will be met. [PR9]1 calculations provide all information ❑Does Not with which compliance can be ❑Not Observable Location on plans/spec:A-1 determined for the additional energy efficiency package options. ❑Not Applicable 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: Y:\Schermerhom\Wedgewood Apartments\Wedgewood Apartments.cck Page 7 of 20 Section # Plan ReviewComplies? Comments/Assumptions &Req.ID C402.3.1 Vertical fenestration area <=30 ❑Complies .Requirement will be met. [PR10]1 percent of the gross above-grade wall ODoes Not area. ❑Not Observable Location on plans/spec:A-1 ❑Not Applicable C402.3.1 Skylight area <=3 percent of the ❑Complies Requirement will be met. [PRll)l grass roof area. ❑Does Not []Not Observable Location on plans/spec:A-1 ❑Not Applicable C402.3.2. Areas with obstructions that block ❑Complies Exception:Skylights designed to exclude direct sunlight 2 direct beam sunlight on>= 1/2 of the []Does Not entering the occupied space by the use of fixed or automated [PR15)1 roof over the enclosed area for more ❑Not Observable baffles. than 1,500 daytime hours per year between 8 am and 4 pm. ❑Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: YASchermerhom\Wedgewood Apartments\Wedgewood Apartments.cck Page 8 of 20 M n Footing/Foundation Plans Verified FieldVerified Complies? Comments/Assumptions ID Inspection Value Value C402.2.6 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies [FO3]2 ❑ Unheated ❑ Unheated ❑Does Not table for values. ❑ Heated ❑ Heated ❑Not Observable ❑Not Applicable C303.2 Slab edge insulation installed per ❑Complies Requirement will be met. [FO4]2 manufacturer's instructions. ❑Does Not ❑Not Observable Location on plans/spec.A- ❑Not Applicable 1 C402.2.6 Slab edge insulation ft ft ❑Complies See the Envelope Assemblies [FO5]2 depth/length.Slab insulation ❑Does Not table for values. extending away from building is covered by pavement or>=10 []Not Observable Inches of soil. ❑Not Applicable C403.2.7, 'Exterior Insulation protected = ❑Complies Requirement will be met. C408.2.8, against damage,sunlight, ❑Does Not C404.5 moisture,wind,landscaping and 1 x <• (FO6]1 equipment maintenance �° it ❑Not Observable activities. Y ❑Nat Applicable C403.2.4. Freeze protection and snow/ice ❑Complies Exception: Requirement 5 melting system sensors for future ❑Does Not does not apply. [FO9]3 connection to controls. 7 ❑Not Observable ❑Not Applicable C402.2.8 Bottom surface of floor structures �� <❑Complies Exception:Requirement [FO12]3 incorporating radiant heating -'[]Does Not does not apply. insulated to>=R-3.5. ❑Not Observable See the Envelope Assemblies ❑Not Applicable table for values. Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: Y:\Schermerhom\Wedgewood Apartments\Wedgewood Apartments.cck Page 9 of 20 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions &Re .ID C402.4.1, The building envelope contains a JDComphes Requirement will be met. C402.4.2 continuous air barrier that is ;DDoes Not [FR16]1 sealed in an approved manner ❑Not Observable Location on plans/spec:A- and either constructed or tested 1 in an approved manner.Air UNot Applicable barrier penetrations are sealed in an approved manner. C402.4.3, Factory-built fenestration and DComplies Requirement will be met. C402.4.4 doors are labeled as meeting air ❑Does Not [FR18]3 leakage requirements. ❑Not Observable :❑Not Applicable C402.4.7 Vestibules are installed on all DComplies Exception:Requirement [FR17]3 building entrances.Doors haveDDoes Not 'does not apply. self-closing devices. s❑Not Observable ;.. ;❑Not Applicable C402.3.3, Vertical fenestration U-Factor. U- U- ❑Complies See the Envelope Assemblies C402.3.4 ❑Does Not table for values. [FRS]1 []Not Observable ❑Not Applicable C402.3.3 :Vertical fenestration SHGC value. SHGC: SHGC: ❑Complies See the Envelope Assemblies [FR10]1 ❑Does Not table for values. ❑Not Observable ❑Not Applicable C303.1.3 Fenestration products rated in ;❑Complies Requirement will be met. [FR12]2 accordance with NFRC. DDoes Not ❑Not Observable Location on plans/spec:A- ❑Not Applicable 1 C303.1,3 Fenestration products are ❑Complies Requirement will be met. [FR13]1 certified as to performance labels...; _ DDoes Not or certificates provided. { Location on plans/spec:A- ❑Not Observable 1 ❑Not Applicable C402.2.7 U-factor of opaque doors U U- ❑Complies See the Envelope assemblies [FR14]2 associated with the building Swinging ❑ Swinging DDoes Not table for values. thermal envelope meets requirements. [3 Nonswinging E] Nonswinging [:]Not Observable ONot Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: Y:\Schermerhom\Wedgewood Apartments\Wedgewood Apartments.cck Page 10 of 20 Section # Plumbing Rough-In inspectionComplies? Comments/Assumptions &Re .ID C404.3 Temperature controls Installed on ❑Complies Requirement will be met. [PL5]3 service water heating systems(110 QF ❑Does Not for dwelling units and lavatories in ❑Not Observable Location on plans/spec:A-1 public restrooms and 90 QF for other occupancies.) ❑Not Applicable C404.4 Automatic time switches installed to ❑Complies Requirement will be met. [PL311 automatically switch off the []Does Not recirculating hot-water system or heat ❑Not Observable Location on plans/spec:A-1 trace. DNot Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: Y:\Schermerhorn\Wedgewood Apartments\Wedgewood Apartments.cck Page 11 of 20 Section Mechanical Rough-in Plans Verified Field Verified # Complies? Comments/Assumptions. & Reg.It} Inspection Value Value C403.2.3 HVAC equipment efficiency Efficiency: Efficiency: ❑Complies See the Mechanical Systems list [ME55]2 verified. ❑Does Not for values. ❑Not Observable ❑Not Applicable C402.4.5. 'Stair and elevator shaft vents ❑Complies Exception: Requirement 1 have motorized dampers that ❑Does Not does not apply. [ME313 automatically close. "[]Not Observable :,[]Not Applicable C402.4.5. Outdoor air and exhaust systems ❑Complies Exception:Gravity dampers 2 have motorized dampers that ❑Does Not acceptable in systems with [ME58]3 ,automatically shut when not in x outside or exhaust air flow use and meet maximum leakage Not Observable _rates less than 300 cfm. rates.Check gravity dampers '❑Not Applicable where allowed. ` C403.2.5. ;Demand control ventilation ❑Complies Exception:Requirement 1 provided for spaces>500 ft2 and t � x 3� < ,� f's❑Does Not 'does not apply. IME591' >25 people/1000 ft2 occupant ; ❑Not Observable :density and served by systems with air side economizer,auto - 4 N []Not Applicable modulating outside air damper control,or design airflow>3,000 cfm. C403.2.7 HVAC ducts and plenums R- R- ❑Complies Exception:Requirement (ME60]2 insulated.Where ducts or ❑Does Not 'does not apply. ,plenums are installed in or under a slab,verification may need to ❑Not Observable occur during Foundation ❑Not Applicable Inspection. 0403.2.8 'Thermally ineffective panel :❑Complies Exception:Requirement (ME4113 surfaces of sensible heating ❑Does Not does not apply. panels have insulation>=R-3.5. []Not Observable ❑Not Applicable p ❑Complies Exception: Requirement 0403.2.7 Ducts and lenums sealed based [ME10]2 on static pressure and location. ❑Does Not does not apply. �t ❑Not Observable t,4 ❑Not Applicable C403.2.7. Ductwork operating>3 in.water omplies Exception: Requirement 1.3 column requires air leakage �� ❑Does Not does not apply. (ME11]3 testing. ' R []Not Observable * ❑Not Applicable C408.2.2. Air outlets and zone terminal ,. f�;� �,�>x � ❑Complies ':Exception: Requirement 1 'devices have means for air ❑goes Not does not apply. [ME5313 balancing. „❑Not Observable ❑Not Applicable 0403:4.2 ;VAV fan motors>=5.0 hp to be F1 VSD VSD ❑Complies Exception:Requirement (ME66]2 ',driven by variable speed drive, ❑ Vane axial ❑ Vane axial ❑Does Not does not apply. have a vane-axial fan with fan fan variable pitch blades,or have ❑ Other Other ❑Nat Observable F1 controls to limit fan motor ❑Not Applicable demand. 0403.4.2 VAV fan motors>=5.0 hp to be El VSD VSD ❑Complies Exception: Requirement [ME66]2 driven by variable speed drive, ❑ Vane axial ❑ Vane axial ❑Does Not does not apply. have a vane-axial fan with fan fan ariable pitch blades,or have ❑ Other ❑ Other []Not Observable `v controls to limit fan motor ❑Not Applicable demand. 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: YASchermerhorn\Wedgewood Apartments\Wedgewood Apartments.cck Page 12 of 20 Section Mechanical Rough-In Plans Verified Field Verified # Inspection Value Value 'Complies. Comments/Assumptions & Req.ID C403.2.6 Exhaust air energy recovery on ❑Complies [ME57]1 systems meeting Table C403.2.6 El Does Not ❑Nat Observable ❑Not Applicable C403.2.11 Unenclosed spaces that are ❑Complies Exception: Requirement [ME71]2 heated use only radiant heat. ❑Does Not does not apply. ❑Not Observable ❑Not Applicable C403.4.7 Hot gas bypass limited to: <=240 ❑Complies Requirement will be met. [ME35]1 kBtu/h-50%a240 kBtu/h-25% ❑Does Not ❑Not Observable Location on plans/spec: A- ❑Not Applicable 1 C403.14 Sleeping rooms in Group R-1 ❑Complies Exception: null. [ME76]3 occupancies are provided with F-1 Does Not dedicated system to automatically control HVAC ❑Not Observable systems and energy consumption ❑Not Applicable during unoccupied periods. Controls are designed to raise cooling and lower heating temperature set points by at least 4°F when room is unoccupied. C403.3.4 Sleeping rooms in Group R-1 ❑Complies Exception: null. [ME76]3 occupancies are provided with ❑Does Not dedicated system to automatically control HVAC ❑Nat Observable systems and energy consumption ❑Not Applicable during unoccupied periods. Controls are designed to raise cooling and lower heating temperature set points by at least 4"F when room is unoccupied. Additional Comments/Assumptions: 11 High Impact(Tier 1) ! 2 Medium Impact(Tier 2) 3 Low Impact(Tier 37) Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: YASchermerhornlWedgewood Apartments\Wedgewood Apartments,cck Page 13 of 20 Section # Rough-In Electrical inspection Complies? Comments/Assumptions &Re .ID C405.2.2 Automatic controls to shut off all ❑Complies Exception: Emergency egress lighting. 1 building lighting installed in all []Does Not [EL22]2 buildings. ONot Observable ❑Not Applicable C405.2.1. Independent lighting controls installed ❑Complies Requirement will be met. 1 per approved lighting plans and all ❑Does Not [EL23]2 manual controls readily accessible and []Not Observable Location on plans/spec:A-1 visible to occupants. ❑Not Applicable C405.2.1. Lighting controls installed to uniformly ❑Complies Exception:Sleeping units. 2 reduce the lighting load by at least ❑Does Not [EL15]1 50%. ;❑Not Observable' ❑Not Applicable C405.2.2. Daylight zones provided with :❑Complies Exception:Requirement does not apply. 3 individual controls that control the ❑Does Not [EL16]2 !lights independent of general area 'lighting. ❑Not Observable ❑Not Applicable C405.2.3 ;Sleeping units have at least one ❑Complies Requirement will be met. [EL17]3 :master switch at the main entry door ❑Does Not :,that controls wired luminaires and ❑Not Observable switched receptacles. ❑Nat Applicable 0405.2.2. Occupancy sensors installed in ❑Complies Exception:Requirement does not apply. 2 required spaces. :❑Does Not [EL18]1 []Not Observable ❑Not Applicable C405.2.2. Primary sidelighted areas are ❑Complies Exception:Requirement does not apply. 3 equipped with required lighting :❑Does Not [EL20]1 controls. :❑Not Observable []Not Applicable C405.2.2. Enclosed spaces with daylight area ❑Complies Exception:Requirement does not apply. 3 under skylights and rooftop monitors ❑Does Not [EL21]1 are equipped with required lighting []Not Observable controls. ❑Not Applicable C405.2.4 Automatic lighting controls for exterior'❑Complies Requirement will be met. [EL25]2 lighting installed. ❑Does Not ❑Not Observable Location on pians/spec.A-1 ❑Not Applicable C405.2.3 Separate lighting control devices for ❑Complies Requirement will be met. [EL4]1 specific uses installed per approved ;❑Does Not lighting plans. []Not Observable Location on plans/spec:A-1 ❑Not Applicable C405.4 Exit signs do not exceed 5 watts per [ Complies Exception:Requirement does not apply. [EL6]1 face. ❑Does Not :❑Not Observable :❑Not Applicable C405.2.3 Additional interior lighting power ❑Complies Requirement will be met. [ELS]1 allowed for special functions per the ,❑Does Not approved lighting plans and is ❑Not Observable location on plans/spec:A-1 automatically controlled and ❑Not Applicable separated from general lighting. Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: Y:\Schermerhorn\Wedgewood Apartments\Wedgewood Apartments.cck Page 14 of 20 I I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: Y:15chermerhomlWedgewood Apartments\Wedgewood Apartments.cck Page 15 of 20 Section Plans Verified Field Verified #' ` Insulation Inspection Compi=es? Comments/Assumptions &Re .III Value Value C402.4.1. :All sources of air leakage in the []Complies Requirement will be met. 1 'building thermal envelope are DoesNot [IN1]1 sealed,caulked,gasketed, []Not Observable ;Location on plansispec:A- weather stripped or wrapped with-,'._*.: 1 moisture vapor-permeable ;❑Not Applicable wrapping material to minimize air leakage. C402.4.9 ;Vapor retarders an the interior 41r = x ;❑Complies Requirement will be met. [1N18]1 side of framed walls,floors and '❑Does Not ceilings where the framed cavity ar Location on plans/spec:A- is not ventilated to allow a ❑Not Observable 1 moisture to escape.Does not k _ ;0Not Applicable include below-grade assembles C402.4.2. 'Roof R-value.For some ceiling R- R- ❑Complies See the Envelope Assemblies 1 :systems,verification may need to table for values. Y Y Above deck ❑ Above deck ❑Does Not [IN2]1 ;occur during Framing Inspection. ❑ Metal ❑ Metal []Not Observable ❑ Attic ❑ Attic ❑Not Applicable C303.2 Roof insulation installed pers a❑Complies Requirement will be met. [IN3]1 manufacturer's instructions. Does Not Blown or poured loose-fill cY` Location on pians/spec:A- insulation is installed only where s r ❑Not Observable 1 the roof slope Is z=3 in 12. „x a,= . _ ❑Not Applicable C303.2 ;Above-grade wall insulation , 'kms { + 4 y 4 s tiOComplies Requirement will be met. [IN7]1 installed per manufacturer's X ❑Does Not Instructions. �f,r ° { Location an A- S ❑Not Observable 1 plans/spec: r '❑Not Applicable C402.2.5 :Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies [IN8]2 Mass ❑ Mass 0Does Not table for values. ❑ Steel ❑ Steel ❑Not Observable ❑ Wood ❑ Wood !❑Not Applicable C303.1 Building envelope insulation is , h ❑Complies Requirement will be met. [IN10]2 labeled with R-value or insulation ❑Does Not certificate providing R-value and I other relevant data. ❑Not Observable ❑Not Applicable C303:2.1 ;Exterior insulation is protected ❑Complies Exception:Requirement [IN14]2 from damage with a protective ❑Does Not does not apply. material.Verification for exposed 'foundation insulation may need ❑Not Observable to occur during Foundation w h ' tkS zY Ar k, „ ❑Not Applicable Inspection. �xs err C402.2.1 Insulation intended to meet the ❑Complies Exception:Requirement [IN1713 roof insulation requirements x f a x ❑Goes Not does not apply. cannot be installed on top of a suspended ceiling.Mark this ;; :❑Not Observable s y� ; J ., L 3t 3r t t - f requirement compliant if r ❑Not Applicable insulation is installed accordingly.. Additional Comments/Assumptions: 11 Nigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: Y:\Schermerhom\Wedgewood Apartments\Wedgewood Apartments.cck Page 16 of 20 Section # Final inspection Complies? Comments/Assumptions & Reg.ID C402.4.6 Weatherseals installed on all loading ❑Complies Exception: Requirement does not apply. [F137]1 dock cargo doors. ❑Does Not ❑Not Observable ONot Applicable C403.2.4. Heating and cooling to each zone is ❑Complies Requirement will be met. 2 controlled by a thermostat control. ❑Does Not [F147]3 Minimum one humidity control device []Not Observable Location on pians/spec:A-1 per installed humidification/dehumidification ❑Not Applicable system. C403.2.4. Thermostatic controls have a 5'F OComplies Requirement will be met. 2 deadband. 'ODoes Not (F138]3 []Not Observable Location on plans/spec:A-1 0Not Applicable C403.2.4. 'Temperature controls have setpoint ;❑Complies :Requirement will be met. 2 overlap restrictions. ODoes Not [F120]3 .[]Not Observable!Location on plans/spec:A-1 UNot Applicable C403.2.4. Each zone equipped with setback :OComplies Requirement will be met. 3 controls using automatic time clock or ODoes Not [F139]3 programmable control system. ❑Not Observable Location on plans/spec:A-1 :❑Not Applicable C403.2.4. Automatic Controls:Setback to 55°F OComplies *Requirement will be met. 3 (heat)and 85°F(cool);7-day clock,2- ODoes Not [F[40]3 hour occupant override, 10-hour []Not Observable'Location on plans/spec:A-1 backup ONot Applicable C408.2.5. :Furnished HVAC as-built drawings OComplies Requirement will be met. 1 submitted within 90 days of system []Does Not [F17]3 acceptance. ONot Observable ❑Not Applicable C303.3,C4 Furnished 0&M manuals for HVAC OComplies Requirement will be met. 08.2.5.2 systems within 90 days of system ODoes Not [FIB]3 acceptance. []Not Observable. ONot Applicable C408.2.5. An air and/or hydronic system ❑Complies Requirement will be met. 3 balancing report is provided for HVAC ❑Does Not [F14311 systems. Location on plans/spec:A-1 IONot Observable ;❑Not Applicable C408.2.3. HVAC control systems have been OComplies Requirement will be met. 2 tested to ensure proper operation, ;❑Does Not [F11011 calibration and adjustment of controls. []Not Observable`Location on plans/spec:A-1 ❑Not Applicable C404.3 Public lavatory faucet water ❑Complies Requirement will be met, [F111]3 temperature<=110°F. ❑Does Not ❑Not Observable Location on plans/spec:A-1 ONot Applicable C404.5 All piping in circulating system OComplies Exception:Requirement does not apply. [FI2512 insulated ❑Does Not ❑Not Observable' ONot Applicable 11 High impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: Y:\5chermerhorn\Wedgewood Apartments\Wedgewood Apartments.cck Page 17 of 20 Section # Final Inspection Complies? Comments/Assumptions &Re .ID C402.4.8 ;Recessed luminaires in thermal ❑Complies Exception: Requirement does not apply. [FI26]3 envelope to limit infiltration and be IC ODoes Not rated and labeled.Seal between interior finish and luminaire housing. ONot Observable ONot Applicable C403.2.2 'HVAC systems and equipment 'OComplies Requirement will be met. [F127]3 capacity does not exceed calculated ❑Does Not loads. Location on plans/spec:A-1 ❑Not Observable' ONot Applicable C408.2.5. Furnished as-built drawings for :❑Complies Requirement will be met. 1 electric power systems within 30 days ❑Does Not [FI16]3 of system acceptance. :❑Not Observable ONot Applicable C303.3,C4 Fumished O&M instructions for OComplies Requirement will be met. 08.2.5.2 systems and equipment to the ❑Does Not [FI17]3 ;building owner or designated representative. 'ONot Observable'. :❑Not Applicable C405.5.2 Interior installed lamp and fixture OComplies See the Interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what ❑Does Not 'is shown on the approved lighting :ONot Observable plans, demonstrating proposed watts ONot Applicable are less than or equal to allowed watts. C405.6.2 Exterior lighting power is consistent `❑Complies See the Exterior lighting fixture schedule for values. [FI19]1 with what is shown on the approved ODoes Not lighting plans,demonstrating proposed watts are less than or equal IONot Observable. to allowed watts. ONot Applicable C408.2.1 :Commissioning plan developed by OComplies Requirement will be met. [F128]1 registered design professional or ;❑Does Not approved agency. '❑Not Observable Location on plans/spec:A-1 ❑Not Applicable C408.2.4 Preliminary commissioning report [ Complies Requirement will be met. [F129]1 completed and certified by registered 'ODoes Not design professional or approved ONot Observable Location on plans/spec:A-1 agency. ONot Applicable C408.2.5. Final commissioning report due to ;OComplies Requirement will be met. 4 building owner within 90 days of :❑Does Not [F130]1 receipt of certificate of occupancy. ONot Observable Location on plans/spec:A-1 ONot Applicable C408.2.3. HVAC equipment has been tested to ❑Complies Requirement will be met. 1 ensure proper operation. ;❑Does Not (FI31]1 Location on plans/spec:A-1 ;ONot Observable ENot Applicable C408.3 Lighting systems have been tested to 'OComplies Requirement will be met. (F133]1 ensure proper calibration,adjustment, ODoes Not programming,and operation. ONot Observable Location on plans/spec:A-1 ONot Applicable C408.3 Lighting systems have been tested to :❑Complies Requirementwill be met. (F148]1 ensure proper calibration,adjustment, []Does Not programming,and operation. ❑Not Observable Location on plans/spec:A-1 ONot Applicable 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: Y:\Schemterhom\Wedgewood Apartments\Wedgewood Apartments.cck Page 18 of 20 Section # Final inspection Complies? Comments/Assumptions &Re .ID C406 Efficient HVAC performance,efficient ❑Complies Requirement will be met. [F134]1 lighting system,or on-site supply of []Does Not renewable energy consistent with []Not Observable Location on plans/spec:A-1 what is shown the approved plans. ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: Y:\Schermerhorn\Wedgewood Apartments\Wedgewood Apartments.cck Page 19 of 20 Project Title: Wedgewood Apartments Report date: 11/03/15 Data filename: Y:1SchermerhornkWedgewood Apartments\Wedgewood Apartments.cck Page 20 of 20