RPLUM-001424-2019 03142019INSPECTION WORKSHEET (RPLUM-001424-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:CC-000362-2016 Case Module:Permit
Inspection Date:Thu Mar 14, 2019 Inspection Status:Failed
Inspector:Mark Smith Inspection Type:Rough Plumbing
Job Address:Parcel Number:8, 10, 14, 16, 20, 22, 26, 28 Wedgewood
DR Bldg. 2
Queensbury, NY 12804
302.9-1-28.1
Contact Type Company Name Name
Applicant Schermerhorn R.E. Holdings VANDERWARKER, DARREN
Contractor Schermerhorn R.E. Holdings VANDERWARKER, DARREN
Granted Permission Schermerhorn R.E. Holdings VANDERWARKER, DARREN
Primary Owner SCHERMERHORN WEDGEWOOD
LLC
Architect Rucinski-Hall Architecture
Checklist Item Passed Comments
Building Inspector Notes NO 7/26/17 Plumbing Under Slab Approved
3/14/19 all plumbing above slab ok. Connection from above
slab to under slab needs to be verified and tested.
Plumbing Under Slab YES 7/26/17 Plumbing Under Slab Approved
Cleanout every 100 feet change of direction YES
Pressure Test YES Still need to test and verify tubs
Drain Vent NO
Mar 14, 2019 Page (1)
INSPECTION WORKSHEET (RPLUM-001424-2019)
Checklist Item Passed Comments
Air Head YES 7/26/17 Plumbing Under Slab Approved
- Pressure test ok! 6 psi
5 psi or 10 ft. above highest conn. for 15 minutes YES 7/26/17 Plumbing Under Slab Approved
- Pressure test ok! 6 psi
Pressure Test NO
Air Head YES Sprinkler system tested with 50 PSI air
Air Test Gas Piping 10 psi for 10 Minutes NO
All Return Air Hard Duct Work NO
Duct Insulation - if required in unheated spaces NO
Duct Testing Outside Conditioned Space NO
Duct work sealed properly NO
Mar 14, 2019 Page (2)
Smith, Mark (Inspector)