BINS-007064-2019 10282019INSPECTION WORKSHEET (BINS-007064-2019)
AST-0644-2019Permit Management
Case Number:Case Module:
10/28/2019Partial Pass
Inspection Date:Inspection Status:
Charles DyerBuilding Foundation
Inspector:Inspection Type:
279.17-2-3
Job Address:Parcel Number:
140 Sunnyside Rd North
Queensbury, NY 12804
Contact TypeCompany NameName
ApplicantEric Sage
Concrete ContractorNorth Valley Constructions Services
ContractorJC Construction
EngineerInfinite Engineering Solutions
Granted PermissionEric Sage
Primary OwnerEric Sage
Checklist ItemPassedComments
Building Inspector NotesFalse
10/16/19 footings approved
10/23/19 foundation walls approved
Footing Drain Stone - 12 inch widthFalse
PVC / Cast / CopperFalse
Foundation / WallpourTrue10/23/19
Masonry WallFalse
Footing Drain Stone - 6 inches above footingFalse
Foundation DampproofingFalseN/A
Plumbing Under SlabFalse
Foundation WaterproofingFalse
Footing Drain Daylight or SumpFalse
Monolithic SlabFalse
FootingsTrue
Footing Drain stone - 6 mil polyFalse
PiersFalse
Backfill ApprovalTrue
Rough Grade 6 inch drop within 10 ft.False
Foundation Insulation Interior / ExteriorFalse
Reinforcement in PlaceTrue
2 rows of # 4 rebar continuous with 1 1/2 key way and #5 vertical
rebar with j hook to be wet set.
Reinforcement in PlaceTrue2 rows of #4 rebar at 48" walls, 3 rows of #4 rebar at 8' walls
Reinforcement in PlaceFalse
Poly Under SlabFalse
Footing Dowels or Keyway in placeTrue1 1/2 key way with #5 rebar vertical dowels wet set
February 04, 2020Page 1 of 1