PTI-007197-2019 11042019INSPECTION WORKSHEET (PTI-007197-2019)
PT-0671-2019Permit Management
Case Number:Case Module:
11/04/2019Passed
Inspection Date:Inspection Status:
Charles DyerProperty Transfer Inspections
Inspector:Inspection Type:
226.12-1-18
Job Address:Parcel Number:
79 Mason Rd
Queensbury, NY 12804
Contact TypeCompany NameName
AgentSteven Cushing
Primary OwnerMARION CUSHING
Checklist ItemPassedComments
Capacity in gallonsTrue1500 gallons
Is there a high water alarm?True
Roof gutters don't discharge over leach fieldTrue
Concrete tankTrue
Temperature (Fahrenheit)True45 degress
D-box materialTrueConcrete
Visible scum layerTrue
Septic tank (include # of tanks)True
1500 gallon septic tank was only 2/3 full, I suspect that the two
piece tank is leaking at the seam. Home owner has agreed to fill
the tank with water to verify if it will hold.
Plumbing fixtures tested & confirmedTrue
Evidence of a pipe bypassing tankTrueNone seen
Tank coverTrueConcrete
System appears to have functioned adequatelyTrueUnable to verify at this time,
System passes all function testingTrue
Does the pump(s) appear to be operating properly?True
Roof runoffTrue
Leaching bedTrue
Depth below grade to top of tankTrue12/16"
Inlet baffleTrue
Test each fixture flow to septic tankTrue
Liquid level AT/ABOVE/BELOW (one) discharge invertTrue
Liquid below discharge level
11/1/19 verified filling of tank, water level with invert, measured
from top of concrete baffle to water level, measures @ 8 1/2 " to
recheck Monday 11/4
Are both switch and alarm operable?True
Solids in D-boxTrueNone seen
Ejector or grinder pump sealedTrue
Pipe from pump station needs to be sealed at cover
11/4/19 pump cover has been replaced with new seals and
gaskets
Outlet baffleTrue
WeatherTrueOvercast
Leaking water fixturesTrueNone seen
OtherTrue
Cracked, corroded or deformed?TrueNothing obvious observed, possible leaking at the seam
February 05, 2020Page 1 of 2
INSPECTION WORKSHEET (PTI-007197-2019)
Checklist ItemPassedComments
Water tight tankTrue
Unable to verify at this time, tank to be filled with water to verify
11/4/19 the septic tank was filled with lake water to verify that is is
not leaking. The fluid level in the tank did not change over the
weekend. The homeowner was advised to pump out the water
from the tank for fear of freezing and has chosen not to do so.