Loading...
2008-472 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 4E Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20080472 Date Issued: Wednesday, November 14, 2012 This is to certify that work requested to be done as shown by Permit Number P20080472 has been completed. Location: 67 LEHLAND Dr Tax Map Number: 523400-295-007-0001-026-000-0000 Owner: MICHAEL & JENNIFER VOGEL Applicant: MICHAEL & JENNIFER VOGEL This structure may be occupied as a: Residential Addition By Order of Town Board r TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan,Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 BayRoad,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERART Permit Number: P20080472 Application Number. A20080472 Tax Map No: 523400-295-007-0001-026-000-0000 Permission is herebygranted to: MICHAEL&JENNIFER VOGEL For property located at 67 LEHLAND Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the QueensburyZonmg Ordinance. Type of Construction Value Owner Address: MICHAEL&JENNIFER VOGEL Residential Addition $50,000.00 67 LEHLAND Dr Total Value QUEENSBURY,NY 12804 $so,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2008-472 600 sq ft residential addition&63 sq ft deck $79.56 PERMIT FEE PAID- THIS PERAHT EXPIRES: Sunday,September 11,2011 (If a longerperiod is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; f,Thursda f September 11,2008 SIGNED BY el for the Town of Queensbury. Director of uilding&Code Enfo TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080472 Application Nu er. A20080472 Tax Map No: 523400-295-007-0001-026-000-0000 Permission is hereby granted to: MICHAEL&JENNIFER VOGEL For property located at: 67 LEHLAND Dr in the Town of Queensbury,to construct or place at the above location in accordance with application toge e with lot p other' ormation ' to filed and approved and in compliance with the NYS Uniform B ' g des d the Quee bury Zo Ordinance. of Cons ction Value 7ntractor jBdder's CHAEL&JENNIFER VOGE LEHLAND Dr Residentia Additi $50,000.00 EENSBURY,NY 12 Total j e $50,000.00 ame/ dr ss ect ' al Inspection Agency Plans &Specifications 2008-472 600 sq ft residential addi 'on & /sq ft deck $79.56 PERMIT FEE PAID- THIS PERMIT EXPIRES: Saturday, September 11, 2010 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the TAmca of Quee bu / p T ursday, September 11, 2008 SIGNED BY for the Town of Queensbury. Director of Building&Co e Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080472 Application Number. A20080472 Tax Map No: 523400-295-007-0001-026-000-0000 Permission is hereby granted to: MICHAEL&JENNIFER VOGEL For property located at: 67 LEHLAND Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: MICHAEL&JENNIFER VOGEL 67 LEHLAND Dr Residential Addition $50,000.00 QUEENSBURY, NY 12804 Total Value $50,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2008-472 600 sq ft residential addition& 63 sq ft deck $79.56 PERMIT FEE PAID- THIS PERMIT EXPIRES: Friday, September 11, 2009 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at o of We day, September 11, 2008 for the Town of Queensbury. SIGNED BY Director of Building&Code Enforcement .............OFFICE USE ONLY -- --- ------ ... ; I....----.------. TAX MAP NO. "� . ' PERMIT NO. ' FEES: PERMIT'�` ,AECREATION ENGINEERING ; (If applicable) ; - ------------------------------------------------------------- --' -------------------= PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: M� �" *61`5q, OWNER: 15; ws ADDRESS: ,4 Dv ire ADDRESS: Giu nn � `f 124' PHONE NOS. �"t� ''l�J2S CXZ- f� `j PHONE NOS. CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: 414 w PHONE: 66046WSP LOCATION OF PROPERTY: (01 L-eAA!A�YJ M-,qe 10 L-:F-4l.ArjV SUBDIVISION NAME: L r1-4(,Awh0 PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT p a 1-- APPLY TO YOUR Z E_ � O d a W w w PROJECT F- 00 1 U- LU a.. 2 Y w -j u_ u_ w Q Cg V z Q Q SU) Na Our. 0LL az0s SINGLE FAMILY x 6100 TWO-FAMILY MULTI-FAMILY (NO.of UNITS) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) �( OTHER-► i''+ ti/� .�--..r lQ"./ IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: 1�►p' ESTIMATED CONSTRUCTION COST: t�,000 FUEL TYPE: GuP-6 HEAT TYPE: �g _*HOW MANY FIREPLACE(S): AND/OR WOODSTOVES(S): _ e)"Ift. ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? gD PROPOSED USE OF BUILDING OR ADDITION: �,oL A9jaao tA1%6115,Af- br-R-pOD0M t *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office C—;ruver w—' B 3-LGL 11-05 utTozvn of Queensbury• Community Development Office • 742 Bay Road, Queensbury, NY 12804 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? 1`L� ARE THERE EASEMENTS ON PROPERTY? 0 I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a.true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. 1 have read and agr t bove. Signed. ?- , raa7 Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above % % This application / proposed action described ; Applicant to erect or alter the building % herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: 01 11 BUILDING &CODES APPROVAL ZONING APPROVAL 10 10 DATE 0, DATE %_______________________________ ........... -----------.------------.............. QUESTIONS? CALL 761-8256 OR EMAIL codes(ftueensburv.net VISIT OUR WESSITE FOR MORE INFORMATION WWW.9U ensbury.net Tonm of Queensbury- Community Develo,w -ont Office - 742 Bay Road, Queensbury, NY 12804 ________________ Q�Toozvn mmunity Development Office ;of Queensbury • 742 Bay Road • Queensbury, New York •12804 01 0 0 Marilyn Ryba, Executive Director• David Hatin, Director of Building&Codes ; 11 Craig Brown, Zoning Administrator ; 00 BUILDING PERMIT CALCULATION SHEET: NATURAL LIGHT, VENTILATION AND EMERGENCY EGRESS REQUIREMENTS REQUIRED ACTUAL ACTUAL LIGHT REQUIRED SQUARE FOOT HABITABLE ROOM AREA OF ROOM IN LIGHT VENTILATION SQUARE FEET 8"%OF ROOM SQUARE V F ROOM AREA SQUARE OPENING FOR REMARKS AREA FOOTAGE OF ROOM AREA FOOTAGE EGRESS �*ZO424- 388 31.0q 32-s6 QUESTIONS? CALL 761-8256 OR EMAIL codes cDqueensburY.net VISIT OUR WEBSITE FOR MORE INFORMATION WWW.quensburV.net B 10-LTR 11-20 Z�P ,;) a -- a ; .------------------- Q�TOWII ommunity Development OfficeV of Queensbury • 742 Bay Road • Queensbury, New York •12804 ' Marilyn Ryba, Executive Director• David Hatin, Director of Building&Codes ' Craig Brown, Zoning Administrator ; WINDOW SCHEDULE ---------------------- JOB SITE/ADDRESS: , T DATE: OWNER: APPLICATION NO.: WINDOW- UNIT OR CLEAR CLEAR WINDOW STOCK ROUGH ROUGH SQ.FT. OPENING NO.OR WINDOW SQ.FT. WIDTH OPENING SPECIAL HARDWARE OR MANUFACTURER NUMBER OPENING OPENING EGRESS/CLEAR HEIGHT LETTER NAME MODEL/TYPE CALL WIDTH HEIGHT VENT OPENING S IN INSTRUCTIONS ON PLAN INCHES SIZE INCHES �� I�J� �sa ��" �l=�rjy' S 7 S. 33G 257 y'1//' /-Il y - - - - �3 ° — �=o '' �= l,5- l 5- 28 e V6 13 26-LTR 11-05 ,,;)p ca6Y-47,)- ---------------------- `` OFFICE USE ONLY PROJECT NAME: _ h26� - Apo rnt>4of' STAFF INITIALS: DATE: BUILDING PERMIT SUBMISSION , CHECKLIST FOR: ' SINGLE FAMILY DWELLING 1. Building Permit Application Completed? YES NO N /A 2 Energy Form or CheckMate Energy Code Compliance Forms Complete? (2-copies) ; 3 Energy Code Inspector's Report from Checkmate i 3 Program? (2-copies) i 4 Septic application completely filled out? (if applicable) 5. I Electrical Inspection Form complete? 1 6. ? Two (2) sets of the plans each of the following: YES NO 1 N /A { a. Floor plans (s)? i b. Foundation plan? ✓ ' ! i a c. Cross sections (s)? I d. Elevations? e. Window and door schedule? I 1 g. Plans signed and sealed by registered architect or engineer? II h. Window and door schedule? Two (2) site plans showing location of the structure to be li 7. built, location of well or water lines, location of septic i system or sewer line? 8. Setbacks from property lines to new structure? $ Setbacks to neighboring wells and septic systems, including onsite well and septic systems (if applicable)? 9. Driveway Permit? Town of Queensbury - Community P 4opment Office - 742 Bay Road, Queensbury, NY 12804 Community Development Office o�- �- q7�L- own of Queensbury - 742 Bay Road - Queensbury, New York -12804 Marilyn Ryba, Executive Director- David Hatin,Director of Building&Codes Craig Brown,Zoning Administrator Electrical Inspectors THE FOLLOWING ELECTRICAL INSPECTION AGENCIES ARE CERTIFIED BY THE TOWN OF QUEENSBURY TO PERFORM ELECTRICAL INSPECTIONS: NAME&ADDRESS OF BUSINESS INSPECTOR CONTACT NUMBER(S) Commonwealth Electrical Inspection Services 357 Elwyn Terrace Donald Loveland Local Office:l-800-562-9934 Manheim, PA 17545 Ron Mumblo Ron: 518-798-0905 Middle Department Main Office: 1-800-873-6432 143 Troy Schenectady Road Joseph Holmes Local Office: 1-800-479-4504 Watervliet, NY 12189 Joe: 518-273-0861 The Inspector, LLC Main Office: 1-800-487-0535 4755 McConchie Rd. Richard Moon Local Office: (518) 882-6140 Galway, NY 12074 Richard: 518-857-6233 New York Board of Fire Underwriters 40 Fulton Street-61h Street Walter Sonntag Local Office: (518) 463-2122 New York, New York 12210 PLEASE NOTE: WE CANNOT RECOMMEND AN INSPECTOR, HOWEVER, PLEASE ASK YOUR CONTRACTOR WHO HE PREFERS TO INSPECT HIS WORK. B 4-LTR 11-05 Check Residential Plan Review: One& Two Family Dwellings YIN/N/A V1 2) ull sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 50 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: indow Schedule With Glass Size or Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade, 5.7 sq. ft. Grade, 5.0 sq. ft. "(h)x 20"(w)min. 44"Max.Height above floor sidential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofing/Waterproofing Materials On Plans W1/�'Pdundation Drainage On Plans, if required 6" rop in 10' Exterior Grade g Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where VARgElfifired d Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls 1tforms At Exterior Doors fairway Headroom 6' 8' All Stairs 36"Width Stair Run and Rise 10 Winder Run and Rise �Ipiral Not Allowed From 2d Story woke Detectors Battery Backup and Proper Location athroom Fixtures Proper Clearance Ll 501 Width, 36"min. andrails More Than Four Risers On Open Sides iling and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation G ge Floor Sloped A Access Roo over 30"—22"x 30"/Crawl Spaces 18"x 24"Access arbon Monoxide Detector Outside Lowest Sleeping Area, On Every Level& Interconnected Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed h LkjlL,, ./ 0 ' Gbeensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: rte K. De -� Date Inspection request received: Inspector's NAME: V PERMIT#: LOCATION: 9,hS 40 A DATE: TYPE OF STRUCTURE: Comments: Yes No N/A 4" Building Number Address visible from road Chimney Height/wW VentUrect Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 incV s above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Hand' Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to silt plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors I main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 sq.ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed properly/Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within fine of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Tern 110 Enclosed Stairs Sheetrodc Underside minimum',"Gypsum Basement stairs dosed rise>4 inches 7— Garage Floor Pitched Garage fire /%hour fire door/door closer � Gas Logs in Sealed or Glass Enclosure - Final Electrical;Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Septic System/Sewer Dept Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Oka to issue C/C or C 10 Temporary/Permanent L:\Building&Codes Forms\Building&Codesllnspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08;Revised 12=10,Revised 04/13/11 RX DatelTiMe 12/11/2012 12:38 518 273 1202 P.003 'Dec. 11, 2012C12: 36P�MDIA, Watervliet, NY "'` " = MIDDLE DEPARTMENT INSPECTION AGENCY, INC. i6r4* that-the electrical wiring to the electrical equipment listed below has been examined and is approved as being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date noted below and is issued subject to the following conditions. Owner: Date: w' Vogal 11/06/2012 ;, Location: Occupant. Same 67 Leland Drive Queensbury,Warren Co. NY ,;; Occupancy: Single Family Dwg. Applicant: z Brown Brother's Elec. Inc. 4 168 Broad St. �,; Glens Falls, NY 1280:1 L _J Joseph A.Holmes No. 144003;1.���1;�96L�;.#:.,'_?y;:��<' °`.�• -. '�r',' Equipment: 10-Switches; 12-Receptacles; 18;`-°'f=fixtures; 1'`=100` ip55ub Panel;3='Smoke`Detectors }err rr�, This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. This certificate applies only to the use.occupancy and above and the installation inspected as of the above noted date based on a visual ownership as Indicated herein. Upon a change in the use,occupancy or ownership inspection. No warranty is expressed or implied as to the mechanical safety,efli- of the property indicated above,this certlfkate shall be immediately null and void. ciency or illness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes invalid based upon the above conditions, be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Oepartment system to which this certificate applies be altered In any way.Including but not limit- Inspection Agency,Inc. An application for inspection must be submitted to Middle ed to,the introduction of additional electrical equipment and/or the replacement of Department Inspection Agency, Inc.to Initiate the inspection and revalidation any of the components installed as of the above noted date,this certificate shall be process. A fee Will be Charged for this service. i r 7 Queensbury Building & CodeZfo E ent - Re2dl Fin l l pection Office No. (518) 761-8256 Arrive: 1= a rt: :- a Date Inspection request ive ; Inspector's Initi NAME: � �-r P MIT#: 4j` LOCATION: E: TYPE OF STRU TORE: Comments: Yes 1'uA 4° Building Number Address visible fromroad Chimney Height/"B°Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 Inches Roof Complete/Exterior Finish Complete Platform at all exterior doors _ Handrail 4 or more risers Guards at stairs deckspatios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall tnterior/Extedor Railings 34 inches to 38 inches Deck Bradn /Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to silt plate Gas Valve shut-off ex sed/regulator 18 inches above grade Interior priM/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazina/Window in stairwells p 12ty glazing interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, i N.ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trapt Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'A",Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched 0-5� ��'_ Garage fireproofing/%hour fire door/door closer Duct work Sealed propedy Gas Logo in Sealed or Glass Enclosure Final Electrical Final SurveyPlot Plan Are Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if rR uired Okay to issue C/C or C 10 Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc;Revised January 7,2008;Revised 6/26/08 Queensbury Building & C e �nforcernent - Resi entiai F' al Inspection No. (518)761-8256 Arrive: a m rt: a Date Inspection request received: Inspector's Initia s: NAME: P MIT#: LOCATION: Ar- ATE: — 2- 1 1 TYPE OF STRUCTURE: Comments: 4' Building Number Address visible from road Chimney Height/'S'Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 Inches Roof Ca I Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs decks ios more than 30 inures above grade Guard at stairwell at 34 inches or more Guard at deck es 36 inches or more t"l� Handrail Termination at Newell Post or Wall Intertor/Extertor Railings 34 inches to 38 inches Deck Brad /HandicappLd Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off e /regulator 18 inches above grade Q � E �� Interior /trim/doors/main entrance 36 inches V Bathroom/Kitchen watertf ht �E "T� Cc-c(� Safety /Window in stairwells safe i Interior Smoke Detectors/Carbon Monoxide Detectors / Every level: Every Bedroom: Outside every bedroom area: \A fNb Inter Connected: Batt badcu : Cz C5 Attic access 30 inches x 22 inches x 30 inches eight in accessible area Crawl Spaces 18 inch x 24 inch access 1 sq.ft:150 sq.ft.vents f o Bathroom Fans if no window Plumbina fixtures Foundation insulation/Insulation Certification Floor truss drafts in finished basement tow sq.ft. t�� Ememency earess below grade Gas Furnace shut-off within 30 feet or within fine of site Oil Furnace shutoff at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler t Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed oMpEdl Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Broker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer De . lns on Sticker Site Plan /Variance required Flood Plain Certification if required Okay to issue C/C or C/Q 1 Temporary/Permanent L\Bulkling&Codes Forms\Building&Codes\Insped#on FormsWesidential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/2M Rough Plumbing / Insulation In ection Report Office No. (518) 761-8256 Date Inspection r cyst r a _ Queensbury Building & Code Enforcement Arrive: �' art , m 742 Bay Road, Queensbury, NY 12804 Inspector's Initia NAME: / PERMIT #: — , Y72- LOCATION:-- INSPECT ON: , TYPE OF STRUCTURE: Y N NIA Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 for 15 minutes -Iffs—Watibn/Nsidential Check/Commercial Check Tyvek or Simi r Exterior Sealant Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct worts sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Rough Plumbing / Insulation Inspection Re ort Office No. (518) 761-8256 Date Inspection r s re ' Queensbury Building &Code Enforcement Arrive: art: m 742 Bay Road, Queensbury, NY 12804 Inspector's Initia 4-7 ZZ NAME: PER IT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping or minutes eln!su!lalion�/ identia{ Check/Commercial Check r Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depalcpm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:/LAlj_jN NAME: Ate' PERMIT#: LOCATION: SPECT ON: -- �V22— TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials on site. Foundatio /Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing ` 6 ly for wet areas under slab Backfil pproval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Ins cti request received: � �S 0`� Queensbury Building&Code Enforcement Arrive: - am/ Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector' itials:`�, NAME: �� ��` PERMIT#: D Z LOCATION: A,,\j DE INSPECT ON: TYPE OF STRUC . Comment Y N NA ,pnotings Piers Monolithic Slab Reinforcement in Place The contractor is respoble for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM CREScheck Software Version 4.1.3 NJ( Compliance Certificate Project Title: New Residential Addition Report Date:08/28/08 Data filename:Y:\Vogel-Mike&Jen\const.dwg's\Vogel.rck Energy Code: 2007 New York Energy Conservation Construction Code Location: Warren County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 19% Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/Contractor: 67 Lehland drive Mike lli Jeri Vogel Ethan P.Hall Queensbury,NY 12804 67 Lehland Drive Rucinski Hall Architecture Queensbury,NY 12804 627 Maple Ave Saratoga Springs,NY 12866 518-580-1905 ephail@nycap.rr.com Compliance: Passes Compliance:13.9%Better Than Code Maximum UA:151 Your UA:130 Gross Cavity Cont. Glazing UA Assembly Area or R-Value R-Value or D•. Perimeter U-Factor Ceiling 1:Raised or Energy Truss 600 38.0 0.0 15 Wall 1:Wood Frame,16"o.c. 630 21.0 0.0 31 Window 1:Vinyl Frame:Double Pane with Low-E 35 0.340 12 Window 2:Vinyl Frame:Double Pane with Low-E 20 0.340 7 Window 3:Vinyl Frame:Double Pane with Low-E 30 0.340 10 Wall 2:Wood Frame,16"o.c. 92 21.0 0.0 2 Window 4:Vinyl Frame:Double Pane with Low-E 15 0.340 5 Door 1:Glass 39 0.340 13 Crawl 1:Solid Concrete or Masonry 420 0.0 10.0 35 Wall height:6.0' Depth below grade:4.0' Insulation depth:5.0' Inside below-grade depth:0.0' Furnace 1:Forced Hot Air89 AFUE Air Conditioner 1:Electric Central Air13 SEER The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the 2007 New York Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and__professional judgment,such plans or specifica' are in this Code. Name-Title t f- e 0 Date ki r� Project Notes: Res-Check is provided for new addition only t. ^- !, c :ate y3 x e KTD Project Title: New Residential Addition Report date: 08/28/08 Data filename:Y:\Vogel-Mike&Jen\const.dwg's\Vogel.rck Page 1 of 4 CREScheck Software Version 4.1.3 NJ( Inspection Checklist Date:08/28/08 Ceilings: ❑ Ceiling 1:Raised or Energy Truss,R-38.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. Above-Grade Walls: ❑ Wall 1:Wood Frame,16"o.c.,R-21.0 cavity insulation Comments: ❑ Wall 2:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: Windows: ❑ Window 1:Vinyl Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 2:Vinyl Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 3:Vinyl Frame:Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 4:Vinyl Frame:Double Pane with low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Glass,U-factor:0.340 Comments: Crawl Space Walls: ❑ Crawl 1:Solid Concrete or Masonry,6.0'ht/4.0'bg/5.0'ext.insul/Off inside bg depth,R-10.0 continuous insulation Comments: Applies to walls of unventilated crawl spaces. Exterior insulation has a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. Heating and Cooling Equipment: ❑ Furnace 1:Forced Hot Air:89 AFUE or higher Make and Model Number: ❑ Air Conditioner 1:Electric Central Air:13 SEER or higher Make and Model Number: Project Title: New Residential Addition Report date:08/28/08 Data filename:Y:\Vogel-Mike&Jen\const.dwg's\Vogel.rck Page 2 of 4 Air Leakage: Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation. Vapor Retarder: Ll Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: Lj Materials and equipment are installed in accordance with the manufacturer's installation instructions. Materials and equipment are identified so that compliance can be determined. Li Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. Ll Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building plans or specifications. 0 Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: Lj Supply ducts in unconditioned attics or outside the building are insulated to at least R-11. Ll Return duds in unconditioned attics or outside the building are insulated to at least R-6. Lj Supply ducts in unconditioned spaces are insulated to at least R-11. Ll Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements. Duct Construction: ❑ All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,or tapes.Tapes and mastics are rated UL 181A or UL 181 B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). Lj The HVAC system provides a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Lj Separate electric meters exist for each dwelling unit. Fireplaces: Lj Fireplaces are installed with tight fitting non-combustible fireplace doors. Lj Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Lj Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: Lj Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: Lj All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps have a time dock. Heating and Cooling Piping Insulation: Ll HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Project Title: New Residential Addition Report date: 08/28/08 Data filename:Y:\Vogel-Mike&Jen\const.dwg's\Vogel.rck Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure(remperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Project Title: New Residential Addition Report date:08/28/08 Data filename:Y:\Vogel-Mike&Jen\const.dwg's\Vogel.rck Page 4 of 4