SEP-001899-2019 04102019INSPECTION WORKSHEET (SEP-001899-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:CC-000362-2015Case Module:Permit
Inspection Date:Wed Apr 10, 2019Inspection Status:Partial Pass
Inspector:John O'BrienInspection Type:Septic
Job Address:3-23 Wedgewood DR Bldg. 1Parcel Number:302.9-1-28.1
Queensbury, NY 12804
Contact TypeCompany NameName
ArchitectRucinski-Hall Architecture
Primary OwnerSCHERMERHORN WEDGEWOOD
LLC
ApplicantSchermerhorn R.E. HoldingsVANDERWARKER, DARREN
ContractorSchermerhorn R.E. HoldingsVANDERWARKER, DARREN
Granted PermissionSchermerhorn Properties
Checklist ItemPassedComments
Building Inspector NotesNO4/10/19 Septic System Partial Approval - 2 Septic Systems
- Forward an email stating you have inspected the septic
system and approve the installation based on the approved
septic system design.
- Submit As-Built Septic Plan
- Install clean out at 45 degree bend before 22.5 degree bend
to distribution box.
Type of Water: Municipal / Well WaterYESMunicipal
Absorbtion Fields: Total LengthYES2 Septic Systems @ 420'
Length of Each TrenchYES(2) 7 @ 60'
Apr 10, 2019Page (1)
INSPECTION WORKSHEET (SEP-001899-2019)
Checklist ItemPassedComments
Depth of TrenchesYESWest System 18"-30"
East System 18"-24"
Size of StoneYES#2
Building to TankYES4" sch40
Tank to Distribution BoxYES4" sdr35 pvc
Distribution box to Field / PitYES4" pvc to 4" pvc perforated
InletOutlet Pipes & BafflesYESNo filter as per engineer
Engineer Report and As-BuiltNO- Forward an email stating you have inspected the septic
system and approve the installation based on the approved
septic system design.
- Submit As-Built Septic Plan
- Install clean out at 45 degree bend before 22.5 degree
Location of system on propertyNOWest Septic System Installed to the west side of building #1.
East Septic System Installed to the east of building #1 and
the leach field is behind building #3
System Use StatusNO4/10/19 Septic System Partial Approval - 2 Septic Systems
- Forward an email stating you have inspected the septic
system and approve the installation based on the approved
septic system design.
- Submit As-Built Septic Plan
- Install clean out at 45 degree bend before 22.5 degree bend
to distribution box.
Note: Once I receive the email and as-built drawing from the
engineer the septic system can be backfilled.
O'Brien, John (Inspector)