Loading...
2008-503 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUP-A-N- CY Pennit Number. P20080503 Date Issued: Wednesday, January 05, 2011 This is to certify that work requested to be done as shown by Permit Number P20080503 has been completed. Location: 12 SARGENT St Tax Map Number. 523400-302-008-0002-041-000-0000 Owner. KATHLEEN HAROLD Applicant: KATHLEEN HAROLD This structure maybe occ&iREESE Garage Attached By Order of Town Board Residential Addition TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, `' <� Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080503 Application Number. A20080503 Tax Map No: 523400-302-008-0002-041-000-0000 Permission is hereby granted to: WILLIAM REESE KATHLEEN HAROLD For property located at: 12 SARGENT St in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Godes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: KATHLEEN HAROLD WILLIAM RESSE Garage Attached 12 SARGENT St Residential Addition $150,000.00 QUEENSBURY, NY 12804-0000 Total value $150,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2008-503 1799 sq ft single family dwelling& 653 sq ft attached garage $281.18 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday, September 23, 2009 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Twn ouee ury u�September 23,2008 / : SIGNED BY _' , ti/✓'f for the Town of Queensbury. Director of Building&Code Enforcement OFFICE USE NLY 0, /, 1 0 TAX MAP NO. PERMIT NO. Yf ' .0 / FEES: PERMIT E�fi ON ENGINEERING 0 , . (If applicable) - � , PRINCIPAL TR UCT URE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: VAIUA AM qG - OWNER: �c71A1rY) ADDRESS: 1 / ` 0e~ L_3f ADDRESS: Gtt"-:.)� 12,%01 PHONE NOS. �-7�i3 "2�� PHONE NOS. CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: -44A1L.PHONE: 6t9l)-Idl LOCATION OF PROPERTY: SUBDIVISION NAME: t4 1a PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT O a CCU w APPLY TO YOUR z LL O rn PROJECT p I- OJ F n0. _ _ w .� it u- LL W Q O U W p J � d d �"- 1- O F- W i W Z z Q ¢ � 07 N cn O u- F- u- CL 06 SINGLE FAMILY 1K � ( /?/—,t' TWO-FAMILY ` MULTI-FAMILY (NO.of UNITS TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED -I- GARAGE(103) c)" � 1C/".� W�✓ 7 7�f(/ OTHER IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST. S ISO ©DU FUEL TYPE: t4NT. 6rl►S. HEAT TYPE: Aar A19- *HOW MANY FIREPLACE(S):. _AND/OR WOODSTOVES(S): � ZONING CATEGORY: 6 -Z4 ARE THERE WETLANDS ON THIS SITE? 90 IS THIS A HISTORIC SITE? fA6 PROPOSED USE OF BUILDING OR ADDITION:- �64 t46ft Y11I?{ St101 *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3-LGL 11-05 Town of Queensbury• Community Development Office • 742 Bay Road, Queensbury, NY 12804 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? t 0 ARE THERE EASEMENTS ON PROPERTY? T1� I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statemeht/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that-pribr to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read a d agr eta a above. Signed / ZAr Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) -------------_---------------___________ Permission is hereby granted to the above This application / proposed action described ; Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: ; , , 10 BUILDING &CODES APPROVAL ; ZONING APPROVAL , , Z , , DATE ; ; DATE 00 QUESTIONS? CALL T61-8256 OR EMAIL codes0gueensburv.net VISIT OUR WESSITE FOR MORE INFORMATION www.ciueensbury.net "; Tozc►n of Queensbury• Community Development Office • 742 Bay Road, Queensbury, NY 12804 19- 2- ,.� rY , Queensbury Building & Code Enforcement - Residential kinai Inspection Office No. (518)761-8256 Arrive: _am/prp Depart: am/pm Date inspection request received: ' f Inspector's Initials: NAME; PERMtT#: C� LOCATION: i 2 it 'F` `' i DATE: TYPE OF STRUCTURE: Comments: Y N A ,V Building Number Address visible from road Chimney Height/"B'Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors _ Handrail 4 or more risers Guards at stairs decks ios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed I regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen waterti ht Safety glazing/Window in stairwells safe glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Batterybadtu Attic access 30 inches x 22 inches x 30 inches(height)in aooessible area Crawl Spaces 18 inch x 24 inch access, 1 M.ft.-150 s .ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 sq.ft. EMtMgnq earess below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater opprating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'A"Gypsum Basement stairs dosed rise a 4 inches Garage Floor Pitched Garage fireproofing I%hour fire door/door closer Duct work Sear Mperly Gas Loge in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built S2gLc System/Sewer Dept. lns ion Sticker Site Plan /Variance required Flood Plain Certification,if req aired Okay to issue C/C or C/O Temporary/Permanent L:1Buiiding&Codes FormslBuilding&Codesllnspection FormslResidential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/2601 Queensbury Building & Code Enforcement - Residential Final In ction Office No. (518) 761-8256 Arrive: am/pm Depart: am/pm Date Inspection request receiv ��fl�.l ,�t Inspector's Initials: ' NAME: PERMIT* LOCATION: DATE: .VkA .l t y TYPE OF STRUCTURE: Comments: Yes No NIA 4" Building Number Address visible from road Chimney Height/W Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs deckspatios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railin s 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate `- Gas Valve shut-off exposed!re ulator 18 inches above qrade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glpzing Interior Smoke ors/Carbon Monoxid etectors Every level: Every Bed m: / Outside every bedroom area: V J V Inter Connected: ✓ Battery backup: •/ Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 s .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 s .ft. - �` Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site �� �. Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Tem 110 t { Enclosed Stairs Sheetrock Underside minimum'A"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C I C or C 10 Temporary/Permanent LABuilding&Codes Formsl6uilding&Codesllnspection FormslResidential Final Inspection ForM_revised_100405.doc;Revised January 7,2008;Revised 6126/08 Queensburyi ilding.& Code Enforcement - Residential Final Inspection ice No. (518)761-8256 Arrive: am/prn Depai�1AL-1 am/pm Date Inspection request receiv : _ inspector's Initials: i NAME: VPE"I`f#: � LOCATION: DATE: TYPE OF STRUCTURE: Comments• N N/ 4' Building Number Address visible from road � �_Z3 Chimne B Hei ht/' 'Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 incres Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deckporches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracin /Handicapp2d Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade i Interior privacy/trim/doors/main entrance 36 inches , Bathroom/Kitchen watertight Safety glazing/Window in stairwells salety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: -'U Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 N.ft.-1 50 sq.ft.vents Bathroom Fans if no window 1 Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area -�— Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum IN Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Gars a fireproofing/%hour fire door/door closer Dud work Sealed pMperly Gas Loge in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Are Fault Breaker in Bedrooms Fleas Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 Temporary/Permanent LABuilding&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08 /o ---I i)04-`- Rough Plumbing 1 Insulation Inspection Report Office No. (518) 761-8256 Date InK!!? Queensbury Building &Code Enforcement Arrive:742 Bay Road, Queensbury, NY 12804 inspecNAME: S� 'r ��. S!Q LOCATION: Z C S Lae_:INSPECT ON: TYPE OF STRUCTURE: C ` ec Y IN NIA Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check lyvek or Similar Exterior Sealant "Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed propeq/No duct tape COMMENTS: Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised January 7,2008 Rough Plumbing / Insulation Inspectio Report Office No. (518) 761-8256 Date Inspection requ r iv Queensbury Building 8�Code Enforcement Arrive: Z� a art: 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: G NAME: PE , T #: i LOCATION: < INSPECT ON: TYPE OF STRUCTURE: Y N NIA Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.1 for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/ Hot Water Piping Insulation If required unheated s paces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Z --4 Town of Qoeaubu y Dine Marikw 742 Bay Road Qaeesa my,NY ln" 761,$M/761-52®6 fax 7454 37 Factory Built Gas EkSRlace/Stove Inspection Report Netim New Ye&State rgmuu dud a$UL listed,helory bit q*Naooes be mulled a000rdog to the and speaC'rcaofi'oas eosrtaiaed in the IastaNation MaowA paayia$the appiiaaoe.No deviation fma the ss� —alter' mans or is allowed. 9 Scbeftlelmw NasaeF S�. Addoe—�_-- lt� ��L��f�i/-� r App6aaoe tMlaad Pr7r`�C�.r me"# ��7 U©t r 1)sa Al�NL Direct Ven Fradiory Bahl C hmsey Fire Sine Dnbk wa$ Triple WA b udated �z59°lZ Yes Me N/A C MAMestr Floor Protection Clearances to Combustibles(all sides) Firestop(s) Vertical Cruse wait resch-Mom, V/ A Vent Clearances to Combustibles Vent/Chimney Termination Cb nwy bagbt most be 3 feet above rod penetration;2 feet above aty ale oobtr0—wiHdt to feet Gas Shut-Off Valve Combustion Air Hearth Extension(if any) mantel Hdgbt aboweU Witness operation Tank Placement(if Lih wIMe-B►dkftg DepL Y rink-Mm awe Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm D_epart: �� m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: �.. NAME: - lHa rc lC PERMIT #: LOCATION: / INSPECT ON: TYPE OF STRUCTURE: ��•G` I Y N NIA Rough Plumbing/ Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping r 50 P.S.I f r 15 minutes Insulation/ esidential Check/Commercial Check jyve imilar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 --------------------------------------- OFFICE USE ONLY PROJECT NAME: gt5w plopir1ftt'l o0at- ; STAFF INITIALS: DATE: BUILDING PERMIT SUBMISSION , CHECKLIST FOR: ' SINGLE FAMILY DWELLING 1. Building Permit Application Completed? YES NO N /A 2 Energy Form or CheckMate Energy Code Compliance Forms Complete? (2-copies) I S Energy Code Inspector's Report from Checkmate ✓ Program? (2-copies) ' 1 4 Septic application completely filled out? (If applicable) 5. ! Electrical Inspection Form complete? ;;6 Two (2) sets of the plans each of the following: YES NO N /A € ✓ ? i a. Floor plans (s)? ? ; I b. Foundation plan? c. Cross sections (s)? I d. Elevations? —� e. Window and door schedule? pW oA6(S. g. Plans signed and sealed by registered architect or engineer? i 3 h. Window and door schedule? ot-3 Two (2) site plans showing location of the structure to be + / 7. j built, location of well or water lines, location of septic system or sewer line 2 I 8. j Setbacks from property lines to new structure? 8 Setbacks to neighboring wells and septic systems, including onsite well and septic systems (if applicable)? j9. � Driveway Permit? I Town of Queensbury - Community Development Office - 742 Bay Road, Queensbury, NY 12804 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: &"� /6 / Queensbury Building &Code Enforcement Arrive: am/pm Depart: m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: - i. x v NAME: y r PERMIT #: LOCATION: INSPECT ON: r TYPE OF STRUCTURE: R Nail Plates nt/Vents in Place 1 Vi inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping T/ Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 i'�1�j ?'- lG'��� Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: lb 10 Queensbury Building &Code Enforcement Arrive: am/pm Depart: m/pm .- 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: �. k �, NAME: 1 Q PERMIT LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N NIA COMMENTS: Framing'2 � 'Aftjvccess 220 x 3W minimum Jack Studs/Headers Bracing/Bridging , Joist hangers Jack Posts/Main Beams -- Exterior sheeting nailed properly " 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/ w 16 gauge 8 16D nags each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour adoAft Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation Hoge side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling1wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (V1i) 5.7 sf above/below grade 5.0 sf grade L:1Bu kW%&Codes Forms-OMBuildim&CodesYnspedion FomnsTraming FnsboppkV Inspection Report.doc Revised January 7,2006 All-r� ' 10-1'JPn-\ Framing / Firestopping Inspection Report Office No. (518)761-8256 Date In ctiIF Queensbury Building&Code Enforcement Arrive: l% :742 Bay Road, Queensbury, NY 12804 Inspector's InNAME: �%t�h IT#: LOCATION: C INSPECT ON: !�l TYPE OF STRUCTURE: Y N A COMMENTS rami AVICICC—Cess 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. H ✓ �c � eadroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Q J Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls - Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq.ft. floor busses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X CeilingANall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASuiiding&Codes Fortes-OMBuilding&CodeMirapedion FormsTrarmng Fib Inspection Repoitdoc Revised January 7,2006 r 10 - 12 /ioCn-'Re;Framing / Firestopping Ins rt Office No. (518)761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: I a 742 Bay Road, Queensbury, NY 12MX Inspector's Initials:��-1� NAME: +l 1,r) PERMIT#: �r LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N NIA COMMENTS: Framing Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Wails Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq.fL floor trusses Abhor l3oits or less on center ice and water sh' Id 24 inches from wall ('...� n 1, 2, 3 hour Fire wail 2, 3, 4 hour - " Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 518 inch Type X Garage side 5/8 inch Type X Ceilin ri Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Buik*V&Codes Forms-OLDiBuild ft&CodesVnspedion FomtsTmminp Restopping inspedion Repatdoc Revised January 7,2006 Framing�/ Fir es topping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/prn Depart:ffj'�4pmlpm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:.4- NAME: PERMIT# LOCATION: . r INSPECT ON: z TYPE OF STRUCTURE: • Framing Y N WA COMMENTS Attic Access 22' x W minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 'h w 16 gauge 8 16D nails each sift Draft 1,000 sq. ft. floor trusses chor 6k or less on center 1 Ice and water shi Id 24 inches from wall' 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling1wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. CM 5.7 sf above/below grade 5.0 sf grade LASuildkV&Codes Forms-QLMSuilding&CodesUnsimbon Fonns'Frarninp FirestOpprg Inspection ReporLdoc Revised January 7,2008 I Foundation Inspection Report C It', Office No.(518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive• �C) am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspecr's Initials: N f ' G'I C 1 / NAME: PE C �'- RMIT#: LOCATION: '? `�r.. f".;i7 1 , INSPECT ON: �ZI TYPE OF STRUC - Common Y N NA Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab ackfill Approval Plumbing Under Slab PVC/Cast?Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\lnspection Forms\Foundation inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No.(518)761-8256 Date Inspgction-&quest received: Queensbury Building&Code Enforcement Arrive:�4�am/pzn� Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector f s'Inifials: �l NAME: - PERMIT#: cr LOCATION: t2�'�C—r�J 7— INSPECT ON: 1 TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. 'als for this purpose on site. oundatio�Wallpour Reinforcement in Place Foot' g Dowell or Keyway in place Foun4ation Dpiripproofing FoundkiawVaterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Buiiding&CodeAInspection Forms\Foundatlon Inspection Report.doc Last printed 12/20/2005 9:24:00 AM � _ Port 1 K Pe Foundation Ins Ction � Office No.(518)761-8256 Date Insf ection request received: Queensbury Building&Code Enforcement Arrive: am/pT Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspecto s tials: .,; NAME: PERMIT#: r Cam' LOCATION: ''`� c� c .r< INSPECT ON: Z? TYPE OF STRUCTURE: Comments NY N/A Footings Y Monolithic Slab Reinforcement in Place The contractor is responsible providing protection from freet for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain.Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspectioon Report.doc Last printed 12/20/2005 9:24:00 AM r \ REScheck Software Version 4.1.3 Nil Compliance Certificate Project Title: Residential Addition Report Date:09/15/08 Data filename:Y:\Resse Residence\const.dwg's\Resse.rck Energy Code: 2007 New York Energy Conservation Construction Code Location: Warren County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 18% Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/Contractor: 12 Sargent St William Resse&Kathy Herold Ethan P.Hall Glens Falls,NY 12801 12 Sargent St Rucinski Hall Architecture Glens Falls,NY 12801 627 Maple Ave 518-793-2825 Saratoga Springs,NY 12866 518-580-1905 ephall@nycap.rr.com Compliance: Compliance:14.3%.Better Than Code Maximum UA:350 Your UA:300 Gross Cavity Cont. Glazing ILIA Assembly Area or R-Value R-Value or D.. Perimeter U-Factor Ceiling 1:Flat Ceiling or Scissor Truss 472 38.0 0.0 14 Ceiling 2:Raised or Energy Truss 174 30.0 0.0 6 Ceiling 3:Raised or Energy Truss 194 38.0 0.0 5 Ceiling 4:Raised or Energy Truss 305 38.0 0.0 8 Ceiling 5:Flat Ceiling or Scissor Truss 91 0.0 20.0 4 Wall 1:Wood Frame,16"o.c. 1066 21.0 0.0 44 Window 1:Wood Frame:Double Pane with Low-E 104 0.350 36 Window 2:Wood Frame:Double Pane 138 0.350 48 Door 1:Solid 20 0.300 6 Door 2:Glass 40 0.350 14 Wall 2:Wood Frame,16"o.c. 797 21.0 0.0 42 Window 3:Wood Frame:Double Pane with Low-E 56 0.350 20 Basement Wall 1:Solid Concrete or Masonry 518 0.0 10.0 36 Wall height:4.9' Depth below grade:4.0' Insulation depth:4.9' Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 520 30.0 0.0 17 Furnace 1:Forced Hot Air89 AFUE Air Conditioner 1:Electric Central Air13 SEER The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to mee York Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped1`14l� „. ey are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specificatio Code. Name-Title to �s *� 't• Date Project Notes: f 70 Project Title: Residential Addition Report date: 09/15/08 Data filename:Y:\Resse Residence\const.dwg's\Resse.rck Page 1 of 6 Res-Check is provided for addition only Project Title: Residential Addition Report date: 09/15/08 Data filename:Y:\Resse Residence\const.dwg's\Resse.rck Page 2 of 6 REScheck Software Version 4.1.3 Inspection Checklist Date:09/15/08 Ceilings: ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: ❑ Ceiling 2:Raised or Energy Truss,R-30.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. ❑ Ceiling 3:Raised or Energy Truss,R-38.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. ❑ Ceiling 4:Raised or Energy Truss,R-38.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. ❑ Ceiling 5:Flat Ceiling or Scissor Truss,R-20.0 continuous insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame,16"o.c.,R-21.0 cavity insulation Comments: ❑ Wall 2:Wood Frame,16"o.c.,R-21.0 cavity insulation Comments: Basement Walls: ❑ Basement Wall 1:Solid Concrete or Masonry,4.9'ht/4.0'bg/4.9'insul,R-10.0 continuous insulation Comments: Exterior insulation has a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. Windows: ❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?_Yes No Comments: ❑ Window 2:Wood Frame:Double Pane,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 3:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Solid,U-factor:0.300 Comments: ❑ Door 2:Glass,U-factor:0.350 Project Title: Residential Addition Report date: 09/15/08 Data filename:Y:\Resse Residence\const.dwg's\Resse.rck Page 3 of 6 Comments: Floors: ❑ Floor 1:All-Wood JoisttTruss:Over Unconditioned Space,R-30.0 cavity insulation Comments: Heating and Cooling Equipment: ❑ Furnace 1:Forced Hot Air:89 AFUE or higher Make and Model Number: ❑ Air Conditioner 1:Electric Central Air:13 SEER or higher Make and Model Number: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation. Vapor Retarder: ❑ Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R-values,glazing U-factors,and heating equipment efficiency are dearly marked on the building plans or specifications. ❑ Insulation is installed according to manufacturers instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building are insulated to at least R-11. ❑ Return ducts in unconditioned attics or outside the building are insulated to at least R-6. ❑ Supply ducts in unconditioned spaces are insulated to at least R-11. ❑ Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements. Duct Construction: ❑ All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,or tapes.Tapes and mastics are rated UL 181A or UL 181B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system provides a means for balancing air and water systems. Temperature Controls: ❑ Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: ❑ Separate electric meters exist for each dwelling unit. Fireplaces: ❑ Fireplaces are installed with tight fitting non-combustible fireplace doors. ❑ Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: ❑ Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: Project Title: Residential Addition Report date: 09/15/08 Data filename:Y:\Resse Residence\const.dwg's\Resse.rck Page 4 of 6 All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps have a time dock. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Project Title: Residential Addition Report date: 09/15/08 Data filename:Y:\Resse Residence\const.dwg's\Resse.rck Page 5 of 6 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes • Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressurefremperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Project Title: Residential Addition Report date: 09/15/08 Data filename:Y:\Resse Residence\const.dwg's\Resse.rck Page 6 of 6