Loading...
ComCheck . COMcheck Software Version 4.0.7.2 Review rtft II Envelope Compliance Certificate E GjpPst Project Information FILE Energy Code: 2015 IECC Project Title: O'Reilly Auto Parts Store Location: Glens Falls, New York Climate Zone: 6a REVIEWED FOR Project Type: New Construction Vertical Glazing/Wall Area: 7`)/° ENERGY CODE COMPLIANCE Construction Site: Owner/Agent: Designer/Contractor: 682 Glen Street O'Reilly Automotive Phase Zero Design Queensbury, NY 12804 233 South Patterson 35 Pond Park Rd Springfield, MO 65801 Bay 16 Hingham, MA 02043 781-452-7121 LSirois@gmail.com Building Area Floor Area 1-Retail : Nonresidential 7453 Additional Efficiency Package High efficiency HVAC.Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor(e) Perimeter Roof 1:Metal Building,Standing Seam,Double Insulation Layer with 7453 11.0 25.0 0.029 0.031 Thermal Blocks(d),[Bldg.Use 1 -Retail] Floor 1:Slab-On-Grade:Unheated,Vertical 4 ft.,[Bldg.Use 1 - 345 --- 10.0 0.480 0.540 Retail](c) NORTH Exterior Wall 4:Concrete Block:8",Partially Grouted,Cells Empty, 1298 0.0 9.0 0.083 0.080 Normal Density,Furring:Metal,[Bldg.Use 1 -Retail] Door 3:Insulated Metal,Swinging,[Bldg.Use 1 -Retail] 21 --- --- 0.310 0.370 Door 4:Insulated Metal,Non-Swinging,[Bldg.Use 1 -Retail] 48 --- --- 0.340 0.340 EAST Exterior Wall 3:Concrete Block:8",Partially Grouted,Cells Empty, 1322 0.0 9.0 0.083 0.080 Normal Density,Furring:Metal,[Bldg.Use 1 -Retail] SOUTH Exterior Wall 2:Concrete Block:8",Partially Grouted,Cells Empty, 1474 0.0 9.0 0.083 0.080 Normal Density,Furring:Metal,[Bldg.Use 1 -Retail] Window 2:Metal Frame with Thermal Break:Fixed,Perf.Specs.: 370 --- --- 0.320 0.360 Product ID Kawneer,SHGC 0.40,PF 0.50,[Bldg.Use 1 -Retail](b) Door 6:Glass(>50%glazing):Metal Frame,Entrance Door,Perf. 21 --- --- 0.320 0.770 Specs.:Product ID kawneer,SHGC 0.40,[Bldg.Use 1 -Retail](b) WEST Project Title: O'Reilly Auto Parts Store Report date: 04/11/18 Data filename: H:\Retail\OReilly Auto parts\1 -PERMITTED 2117238 Queensbury NY\Queensbury NY Page 1 of 9 ComCheck.cck Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor., Perimeter Exterior Wall 1:Concrete Block:8",Partially Grouted,Cells Empty, 1322 0.0 9.0 0.083 0.080 Normal Density,Furring: Metal,(Bldg.Use 1 -Retail) Door 5:Insulated Metal,Swinging,(Bldg.Use 1 -Retail] 21 --- --- 0.310 0.370 (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. (b)Fenestration product performance must be certified In accordance with NFRC and requires supporting documentation. (c)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. (d)Thermal spacer block with minimum R-3.5 must be installed above the purlin/batt,and the roof deck secured to the purlins. nvelope PASSES: Design 3% better than code Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit a lication. The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Versio 1 4.0.7,2 Review and to comply with any applicable mandatory requirements listed in the Inspection Checklist. ��hM% 'Hm544 -tJP- fi tNu -et-(' • 1.8 Name-title Ignature Date � ARCy(<7kED KI/Lie /)`4g � "' �l! �0 Q t ICP, s'�a•a 1' -1 l), 029423 40 * FoF NE`N Project Title: O'Reilly Auto Parts Store Report date: 04/11/18 Data filename: H:\Retail\OReilly Auto parts\1 - PERMITTED 2117238 Queensbury NY\Queensbury NY Page 2 of 9 ComCheck.cck COMcheck Software Version 4.0.7.2 Review Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans and/or specifications provide all DComplies [PR1]1 information with which compliance ODoes Not can be determined for the building envelope and document where ❑Not Observable exceptions to the standard are ❑Not Applicable claimed. C402.4.1 The vertical fenestration area <= 30 ❑Complies [PR1O]1 percent of the gross above-grade wall DDoes Not area. DNot Observable ❑Not Applicable C402.4.1 The skylight area <= 3 percent of the ❑Complies [PR11]1 gross roof area. ❑Does Not :Not Observable ONot Applicable C406 Plans, specifications, and/or DComplies [PR9]1 calculations provide all information ❑Does Not with which compliance can be determined for the additional energy ['Not Observable efficiency package options. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: O'Reilly Auto Parts Store Report date: 04/11/18 Data filename: H:\Retail\OReilly Auto parts\1 -PERMITTED 2117238 Queensbury NY\Queensbury NY Page 3 of 9 ComCheck.cck Section # 1 Footing/Foundation Inspection Complies? Comments/Assumptions & Req.ID I C303.2 Slab edge insulation installed per ❑Complies [FO4]2 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable C303.2.1 Exterior insulation protected against ❑Complies [FO6]1 damage, sunlight, moisture, wind, ❑Does Not landscaping and equipment maintenance activities. ['Not Observable ❑Not Applicable C402.2.5 Slab edge insulation R-value. ❑Complies See the Envelope Assemblies table for values. [FO3]2 ElDoes Not ❑Not Observable ❑Not Applicable C402.2.6 Radiant heating systems panels OComplies See the Envelope Assemblies table for values. [FO12]3 insulated to>=R-3.5 on face opposite ❑Does Not space being heated. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: O'Reilly Auto Parts Store Report date: 04/11/18 Data filename: H:\Retail\OReilly Auto parts\1 -PERMITTED 2117238 Queensbury NY\Queensbury NY Page 4 of 9 ComCheck.cck Section # • Framing/Rough-In Inspection Complies? Comments/Assumptions & Req.ID C303.1.3 Fenestration products rated in ❑Complies [FR12]z accordance with NFRC. ❑Does Not ['Not Observable ONot Applicable C303.1.3 Fenestration products are certified as ❑Complies [FR13]1 to performance labels or certificates ❑Does Not provided. ONot Observable ONot Applicable C402.4.3 Vertical fenestration SHGC value. ❑Complies See the Envelope Assemblies table for values. [FR10]1 ❑Does Not ['Not Observable ONot Applicable C402.4.3, Vertical fenestration U-Factor. ❑Complies See the Envelope Assemblies table for values. C402.4.3. ❑Does Not 4 [FR8)1 ['Not Observable ONot Applicable C402.4.4 U-factor of opaque doors associated ❑Complies See the Envelope Assemblies table for values. [FR14]2 with the building thermal envelope ['Does Not meets requirements. ❑Not Observable ❑Not Applicable C402.5.1. The building envelope contains a ❑Complies 2.2 continuous air barrier that is sealed in ❑Does Not [FR20]1 an approved manner and average assembly air leakage <= 0.04 cfm/ft2. ['Not Observable Air barrier penetrations are sealed in ONot Applicable an approved manner. C402.5.2, Factory-built fenestration and doors ❑Complies C402.5.4 are labeled as meeting air leakage ❑Does Not [FR1813 requirements. :Not Observable ❑Not Applicable C402.5.7 Vestibules are installed on all building ❑Complies [FR17]3 entrances. Doors have self-closing ❑Does Not devices. ONot Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: O'Reilly Auto Parts Store Report date: 04/11/18 Data filename: H:\Retail\OReilly Auto parts\1 -PERMITTED 2117238 Queensbury NY\Queensbury NY Page 5 of 9 ComCheck.cck Section # ' Mechanical Rough-In Inspection Compiles? Comments/Assumptions & Req.ID C402.5.5, Stair and elevator shaft vents have Complies C403.2.4. motorized dampers that automatically ❑Does Not 3[MEW close. ❑Not Observable ❑Not Applicable C402.5.5, Outdoor air and exhaust systems have DComplies C403.2.4. motorized dampers that automatically ❑Does Not 3 shut when not in use and meet [ME58]3 maximum leakage rates.Check :Not Observable gravity dampers where allowed. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: O'Reilly Auto Parts Store Report date: 04/11/18 Data filename: H:\Retail\OReilly Auto parts\1-PERMITTED 2117238 Queensbury NY\Queensbury NY Page 6 of 9 ComCheck.cck • • Section # ' Insulation Inspection Complies? Comments/Assumptions & Req.ID C303.1 Roof insulation installed per DComplies [IN3]1 manufacturer's instructions. Blown or ❑Does Not poured loose-fill insulation is installed only where the roof slope is<=3 in ❑Not Observable 12. ❑Not Applicable C303.1 Building envelope insulation is labeled DComplies [IN10]2 with R-value or insulation certificate ❑Does Not providing R-value and other relevant data. [Not Observable ❑Not Applicable C303.2 Above-grade wall insulation installed DComplies [IN7]1 per manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable C303.2.1 Exterior insulation is protected from DComplies [IN14]2 damage with a protective material. ❑Does Not Verification for exposed foundation insulation may need to occur during ❑Not Observable Foundation Inspection. ❑Not Applicable C402.1.3 Non-swinging opaque doors have R- DComplies [IN19]3 4.75 insulation. ❑Does Not ❑Not Observable ❑Not Applicable C402.2.1 Insulation intended to meet the roof DComplies [IN17]3 insulation requirements cannot be ❑Does Not installed on top of a suspended ceiling. Mark this requirement :Not Observable compliant if insulation is installed ❑Not Applicable accordingly. C402.2.3 Above-grade wall insulation R-value. DComplies See the Envelope Assemblies table for values. [IN6]1 ❑Does Not ['Not Observable ❑Not Applicable C402.2.5 Floor insulation R-value. DComplies See the Envelope Assemblies table for values. [IN8]2 ❑Does Not ❑Not Observable ❑Not Applicable C402.2.6 Radiant panels and associated DComplies [IN18]3 components, designed for heat ❑Does Not transfer from the panel surfaces to the occupants or indoor space are [Not Observable insulated with a minimum of R-3.5. ❑Not Applicable C402.2.2 Roof R-value. For some ceiling DComplies See the Envelope Assemblies table for values. [IN2]1 systems, verification may need to ❑Does Not occur during Framing Inspection. ❑Not Observable ❑Not Applicable C402.5.1. All sources of air leakage in the DComplies 1 building thermal envelope are sealed, ❑Does Not [IN1]1 caulked, gasketed,weather stripped or wrapped with moisture vapor- ❑Not Observable permeable wrapping material to ❑Not Applicable minimize air leakage. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: O'Reilly Auto Parts Store Report date: 04/11/18 Data filename: H:\Retail\OReilly Auto parts\1-PERMITTED 2117238 Queensbury NY\Queensbury NY Page 7 of 9 ComCheck.cck Section Final Inspection Complies? Comments/Assumptions & Req.ID C402.5.3 Where open combustion air ducts ❑Complies [F151]3 provide combustion air to open ❑Does Not combustion fuel burning appliances, the appliances and combustion air ❑Not Observable opening are located outside the ❑Not Applicable building thermal envelope or enclosed in a room, isolated from inside the thermal envelope.Such rooms are sealed and insulated. C402.5.6 Weatherseals installed on all loading ❑Complies [FI37]1 dock cargo doors. ❑Does Not ONot Observable ❑Not Applicable C402.5.8 Recessed luminaires in thermal ❑Complies [FI26]3 envelope to limit infiltration and be IC ❑Does Not rated and labeled.Seal between interior finish and luminaire housing. ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: O'Reilly Auto Parts Store Report date: 04/11/18 Data filename: H:\Retail\OReilly Auto parts\1 -PERMITTED 2117238 Queensbury NY\Queensbury NY Page 8 of 9 ComCheck.cck Project Title: O'Reilly Auto Parts Store Report date: 04/11/18 Data filename: H:\Retail\OReilly Auto parts\1 -PERMITTED 2117238 Queensbury NY\Queensbury NY Page 9 of 9 ComCheck.cck 111ACOMcheck Software Version 4.0.8.1 ii Interior Lighting Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: O'Reilly Auto Parts Store Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: 682 Glen Street O'Reilly Automotive Phase Zero Design Queensbury,NY 12804 233 South Patterson 35 Pond Park Rd Springfield, MO 65801 Bay 16 Hingham,M Additional Efficiency Package(s) 78-452--7121 02043 LSirois@gmall,com Reduced interior lighting power.Requirements are Implicitly enforced within interior lighting allowance calculations. Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts I ft2 (B X C) 1-Retail 7453 1,13 8452 Total Allowed Watts- 8452 Proposed Interior Lighting Power A B C D E Fixture ID: Description/Lamp I Wattage Per Lamp/Ballast Lamps/ I of Fixture (C X 0) Fixture Fixtures Watt. 1-Retell LED 1:A:Other: 1 52 67 3484 LED 2:B:Other: 1 12 34 408 LED 3:C:Other: 1 33 67 2211 LED 4:D:Other: 1 9 34 306 Total Proposed Watts- 6409 Interior Lighting PASSES: Design 24% better than code Interior Lighting Compliance Statement 4istt+44a? Compliance Statement: The proposed interior lighting design repkelertetyi;ki+]s}doc ent is consistent with the building plans, specifications,and other calculations submitted with this permij4v8pjr�li't,`atton.The`prp p 41 interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck vi fend;(Qi3,?ra[adif8ito, ly'Avith any applicable mandatory requirements listed in the Inspection Checklist. Norman E.Goth, P.E. April 11,2018 Name-Title Si natue, ', ,,;: Date 1. �.• 066752 •a`'J`�v e a • •401#I,ZG)`ES5\a, 0 Project Title: O'Reilly Auto Parts Store Report date: 04/11/18 Data filename: E:\CLIENTS-O'Reilly Active Stores\Queensbury,NY OR17-148 (New)(Leah)\Com Check\Queensb Page 1 of 3 NY ComCheck.cck 114COMcheck Software Version 4.0.8.1 ii Exterior Lighting Compliance Certificate 1 Project Information Energy Code: 2015 IECC Project Title: O'Reilly Auto Parts Store Project Type: New Construction Exterior Lighting Zone 2 (Neighborhood business district) Construction Site: Owner/Agent: Designer/Contractor: 682 Glen Street O'Reilly Automotive Phase Zero Design Queensbury, NY 12804 233 South Patterson 35 Pond Park Rd Springfield, MO 65801 Bay 16 Hingham, MA 02043 781-452-7121 LSirois@gmall.cOm Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts I Unit Wattage (B X C) Driveway 11585 ft2 0,06 Yes 695 Walkway<10 feet wide 1641 ft of 0.7 Yes 1149 Total Tradable Watts(a)- 1844 Total Allowed Watts- 1844 Total Allowed Supplemental Watts(b) = 600 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non tradable and tradable areas/surfaces. Proposed Exterior Lighting Power A B C D E Fixture ID: Description I Lamp I Wattage Per Lamp I Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Driveway(11585 ft2):Tradable_ ttage LED 5:P1:Other: 1 2 154 308 Walkway< l0 feet wide(1641 It of walkway length). Tradable Wattage LED 6:WP1:Other: 1 5 59 295 LED 6:WP2:Other: 1 2 29 58 Total Tradable Proposed Watts• 661 Exterior I ighting PASSES: Design 73%better than code Exterior Lighting Compliance Statement t,��‘ Ur.NEIv/'•,, Compliance Statement: The proposed exterior lighting desigekeiaNs4nted in thts►.f." gent is consistent with the building plans, specifications, and other calculations submitted with this pedrut;appMitli ritfI lt(rCE+itbr.:•s'd exterior lighting systems have been designed to meet the 2015 IECC requirements in COMcheclCder/on 4;9:f.),fhd to c4(npt,with any applicable mandatory requirements listed in the Inspection Checklist. — ' f';.• e - Norman E. Goth, P.E. ! -.. 'iv` April 11. 2018 Name -Title Signal �-• e. 096752 .!„.. Date .4if�,O ,*°...,.y*�*"_` %�` Project Title: O'Reilly Auto Parts Store Report date: 04/11/18 Data filename. E:\CLIENTS-O'Reilly Active Stores\Queensbury, NY OR17-148 (New)(Leah)\Com Check\Queensb Page 2 of 3 NY ComCheck.cck • COMcheck Software Version 4.0.8.1 ii Mechanical Compliance Certificate 11111 Project Information Energy Code: 2015 IECC Project Title: O'Reilly Auto Parts Store Location: Glens Falls, New York Climate Zone: 6a Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: 682 Glen Street O'Reilly Automotive Phase Zero Design Queensbury,NY 12804 233 South Patterson 35 Pond Park Rd Springfield, MO 65801 Bay 16 Hingham, MA 02041 Additional Efficiency Package(s) 781.452-7121 LSirois@gmall.com Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Mechanical Systems List Quantity System Type&Description 3 HVAC System 1 (Single Zone): Heating:3 each-Unit Heater,Gas,Capacity=180 kBlu/h Proposed Efficiency-82.00%Ec,Required Efficiency=80.00%Ec Cooling:3 each-Single Package DX Unit,Capacity-93 kBlu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency- 12.00 EER, Required Efficiency: 11.00 EER + 12.6 IEER Fan System: Unspecified 1 Water Heater 1: Electric Storage Water Healer,Capacity: 19 gallons No minimum efficiency requirement applies Mechanical Compliance Statement Compliance Statement: The proposed mechanical design representq{>•+hdiis7ddd, f?nt is consistent with the building plans, specifications,and other calculations submitted with this permit Iia ton;,titt/pjp}Seyed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck Ve*e_h�4.p.6.1 and td c0 fly with any applicable mandatory requirements listed in the Inspection Checklist. X .'llORat4E.C�l}I ',•. . Norman E. Goth, P.E. o April 11.2018 Name-Title Si r+. •- fi- X Date i'3,'. •096752 L•�i� Z.� Project Title: O'Reilly Auto Parts Store Report date: 04/11/18 Data filename: E:\CLIENTS-O'Reilly Active Stores\Queensbury, NY OR17-148 (New)(Leah)\Com Check\Queensb Page 3 of 3 NY ComCheck.cck