BINS-008654-2018 12102018
INSPECTION WORKSHEET (BINS-008654-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
RC-0467-2018Permit
Case Number:Case Module:
Mon Dec 10, 2018Failed
Inspection Date:Inspection Status:
John O'BrienBuilding Foundation
Inspector:Inspection Type:
1232 WEST MOUNTAIN RD288.-1-65
Job Address:Parcel Number:
Queensbury, NY 12804
Contact TypeCompany NameName
Primary OwnerDwyer, Christopher
ApplicantDwyer, Christopher
Granted PermissionDwyer, Christopher
Checklist ItemPassedComments
Building Inspector NotesNO12/10/18 As per my inspection of the core drilled location in
the slab there is no insulation under the floor. The material
under the floor which is 4-6" thick is some type of the material
that is light brown in color. I have told Mr. Dwyer he needs to
have 2" Foam Board Insulation Installed at the perimeter of
the slab 1' vertical below grade and then 3' horizontal away
from the slab.
FootingsNO
PiersNO
Monolithic SlabNO
Reinforcement in PlaceNO
Dec 10, 2018Page (1)
INSPECTION WORKSHEET (BINS-008654-2018)
Checklist ItemPassedComments
Foundation / WallpourNO12/10/18 As per my inspection of the core drilled location in
the slab there is no insulation under the floor. The material
under the floor which is 4-6" thick is some type of the material
that is light brown in color. I have told Mr. Dwyer he needs to
have 2" Foam Board Insulation Installed at the perimeter of
the slab 1' vertical below grade and then 3' horizontal away
from the slab.
Reinforcement in PlaceNO
Footing Dowels or Keyway in placeNO
Foundation DampproofingNO
Foundation WaterproofingNO
Footing Drain Daylight or SumpNO
Footing Drain Stone - 12 inch widthNO
Footing Drain Stone - 6 inches above footingNO
Footing Drain stone - 6 mil polyNO
Backfill ApprovalNO
Plumbing Under SlabNO
PVC / Cast / CopperNO
Foundation Insulation Interior / ExteriorNO
Rough Grade 6 inch drop within 10 ft.NO
Dec 10, 2018Page (2)
INSPECTION WORKSHEET (BINS-008654-2018)
Checklist ItemPassedComments
Poly Under SlabNO
O'Brien, John (Inspector)
Dec 10, 2018Page (3)