Loading...
BINS-003150-2019 05302019INSPECTION WORKSHEET (BINS-003150-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0467-2018 Case Module:Permit Inspection Date:Thu May 30, 2019 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Building Foundation Job Address:Parcel Number:1232 WEST MOUNTAIN RD Queensbury, NY 12804 288.-1-65 Contact Type Company Name Name Granted Permission Dwyer, Christopher Primary Owner Dwyer, Christopher Applicant Dwyer, Christopher Checklist Item Passed Comments Building Inspector Notes NO 12/10/18 As per my inspection of the core drilled location in the slab there is no insulation under the floor. The material under the floor which is 4-6" thick is some type of the material that is light brown in color. I have told Mr. Dwyer he needs to have 2" Foam Board Insulation Installed at the perimeter of the slab 1' vertical below grade and then 3' horizontal away from the slab. 5/29/19 Foundation Insulation Partial Approval - South & West Elevations (1' vertical 3' horizontal) Ok to backfill these areas. 5/30/19 Foundation Insulation Partial Approval - North Elevation (1' vertical, 3' horizontal) Ok to backfill Footings NO Piers NO Monolithic Slab NO May 30, 2019 Page (1) INSPECTION WORKSHEET (BINS-003150-2019) Checklist Item Passed Comments Reinforcement in Place NO Foundation / Wallpour NO 12/10/18 As per my inspection of the core drilled location in the slab there is no insulation under the floor. The material under the floor which is 4-6" thick is some type of the material that is light brown in color. I have told Mr. Dwyer he needs to have 2" Foam Board Insulation Installed at the perimeter of the slab 1' vertical below grade and then 3' horizontal away from the slab. Reinforcement in Place NO Footing Dowels or Keyway in place NO Foundation Dampproofing NO Foundation Waterproofing NO Footing Drain Daylight or Sump NO Footing Drain Stone - 12 inch width NO Footing Drain Stone - 6 inches above footing NO Footing Drain stone - 6 mil poly NO Backfill Approval NO 5/29/19 Foundation Insulation Partial Approval - South & West Elevations (1' vertical 3' horizontal) Ok to backfill these areas. 5/30/19 Foundation Insulation Partial Approval - North Elevation (1' vertical, 3' horizontal) Ok to backfill Plumbing Under Slab NO May 30, 2019 Page (2) INSPECTION WORKSHEET (BINS-003150-2019) Checklist Item Passed Comments PVC / Cast / Copper NO Foundation Insulation Interior / Exterior NO 5/29/19 Foundation Insulation Partial Approval - South & West Elevations (1' vertical 3' horizontal) Ok to backfill these areas. 5/30/19 Foundation Insulation Partial Approval - North Elevation (1' vertical, 3' horizontal) Ok to backfill Rough Grade 6 inch drop within 10 ft.NO Poly Under Slab NO May 30, 2019 Page (3) O'Brien, John (Inspector)