008021-2018 11152018INSPECTION WORKSHEET (008021-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0467-2018Case Module:Permit
Inspection Date:Thu Nov 15, 2018Inspection Status:Partial Pass
Inspector:Dave HatinInspection Type:Residential Final Inspection
Job Address:1232 WEST MOUNTAIN RDParcel Number:288.-1-65
Queensbury, NY 12804
Contact TypeCompany NameName
Granted PermissionDwyer, Christopher
Primary OwnerDwyer, Christopher
ApplicantDwyer, Christopher
Checklist ItemPassedComments
General CommentsNOVerified kitchen stove and refrigerator
4 inch Building Number Address visible from roadNO
Chimney Height / B Vent / Direct Vent LocationNO
Chimney Rain Cap InstalledNO
Fresh Air IntakeNO
Fresh air supply 3' from gradeNO
3" Plumbing Vent through roof minimum 18 inchNO
Outside Spigots have Air GapNO
Nov 15, 2018Page (1)
INSPECTION WORKSHEET (008021-2018)
Checklist ItemPassedComments
Roof Complete / Exterior Finish CompleteNO
Platform at all exterior doorsNO
Handrail 4 or more risersNO
Guards at stairs,decks,patios 30" + above gradeNO
Guard at stairwell at 34" or moreNO
Window guards req:<2' above floor/6' aboveNO
grade - quick release installed
Guard at deck, porches 36" or moreNO
Handrail Termination at Newell Post or WallNO
Interior/Exterior Railings 34 to 38NO
Wood deck: 2'+ from grade dia bracing required -NO
H/C ramp compliant
4+ Deck Joist Ledger Connections-24" FromNO
Ends
Deck Ledger-Bolted per CodeNO
Grade away from foundation 6 with 10 feetNO
6 clearance to sill plateNO
Nov 15, 2018Page (2)
INSPECTION WORKSHEET (008021-2018)
Checklist ItemPassedComments
Gas Shut-off Exposed & Regulator (18) AboveNO
Grade
HVAC Vent Terminal 10' from Lot Line &NO
Openings
Dryer Duct Max Length 35', Labeled Over 35'NO
Interior privacy/trim/doors/main entrance 36NO
Bathroom / Kitchen WatertightNO
Low flow toilet 1.3 gal/flushing cycle -NO
showerhead/faucet
Safety glazing: w/in 5' of tub/shower - stairwellNO
win/adj to drs
Smoke Detectors: Carbon MonoxideNO
CO in Bedrooms w/GasNO
Smoke Detectors 3' from Kitchens & Baths R314NO
Every level, Every bedroomNO
Outside every bedroom areaNO
Inter ConnectedNO
Battery backup: _____NO
Nov 15, 2018Page (3)
INSPECTION WORKSHEET (008021-2018)
Checklist ItemPassedComments
Attic Access 22 x 30 minimumNO
Attic Access Insulation = Attic R- ValueNO
Attic Access GasketedNO
Crawl Space Access 18 x 24NO
Bathroom Fans, if no windowNO
Plumbing fixturesNO
Backflow Preventors where requiredNO
Foundation insulation to floorNO
Energy Sticker on Elec. Panel:R-Val. & HeatingNO
Sys
All Hot Water Systems: R-3NO
Duct work sealed properlyNO
Intake OpeningsNO
Range Hood 400+ cfm-Fresh Air REQUIREDNO
Blower Door Test CertificationNO
HRV or ERV Installed per Bedroom RequirementsNO
Nov 15, 2018Page (4)
INSPECTION WORKSHEET (008021-2018)
Checklist ItemPassedComments
Floor truss, draft stop- fin base 1,000 sq. ft.NO
Emergency egress below gradeNO
Furnace shut-off w/in 30 ft. or w/in line of siteNO
Oil Furnace Shut-Off at Entrance to Furnace AreaNO
Propane Tank: Proper Setback from PropNO
Line/Struct
Furnace Hot Water Heater operatingNO
Low water shut-off boilerNO
Relief Valve ,Heat Trap/Water Temp 110 deg orNO
less
Encl. Stairs Sheetrock Underside minimum ½NO
Gypsum
1/2" Gypsum or House Wall and GableNO
5/8" Type X with Living Space AboveNO
20 Minute Fire Door/Self-Closing HardwareNO
Seals on Garage Doors, esp. WoodNO
Basement stairs closed rise greater than 4 inchesNO
Nov 15, 2018Page (5)
INSPECTION WORKSHEET (008021-2018)
Checklist ItemPassedComments
Basement Egress: 5s.f. window w/sill or BilcoNO
door
Basement ceiling covered 2x8 fl joist or lessNO
Fireblocking at fl joist 80 s.f. or lessNO
Garage Floor PitchedNO
1/2" Gypsum-Bsmt Ceiling<2x10 Frame/TJI/Fl.NO
Truss
Gas Log In Sealed or Glass EnclosureNO
Fin Elect; Energy Saving Light Bulbs 50 PercentNO
CSST/other piping in conduit if buried,if requiredNO
Final Survey Plot PlanNO
Arc Fault Breaker Habitable SpacesNO
Flex Gas Pipe BondingNO
As Built Septic SystemNO
Sewer Dept. Inspection StickerNO
Site Plan / Variance requiredNO
Flood Plain Certification, if requiredNO
Nov 15, 2018Page (6)
INSPECTION WORKSHEET (008021-2018)
Checklist ItemPassedComments
Fuel Tanks above flood plain elevationNO
Buried Fuel Tanks anchored in flood zoneNO
Truss ID Signage Installed at Electrical MeterNO
OK to Issue Temporary C/ONO
OK to Issue C/ONO
Hatin, Dave (Inspector)
Nov 15, 2018Page (7)