SEP-008207-2018 11202018INSPECTION WORKSHEET (SEP-008207-2018)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0467-2018Case Module:Permit
Inspection Date:Tue Nov 20, 2018Inspection Status:Failed
Inspector:John O'BrienInspection Type:Septic
Job Address:1232 WEST MOUNTAIN RDParcel Number:288.-1-65
Queensbury, NY 12804
Contact TypeCompany NameName
ApplicantDwyer, Christopher
Granted PermissionDwyer, Christopher
Primary OwnerDwyer, Christopher
Checklist ItemPassedComments
Building Inspector NotesNO11/20/18 As per my site visit this morning I met with Mr.
Dwyer and the rep from Rotor Rooter who will camera the
septic system.
The camera revealed that there was just one Infiltrator line
approximately 25' long.
I told Mr. Dwyer he needs to install a compliant septic system
for a 2 bedroom dwelling. He said he will be contracting
George Drellos to file for permit and install system. The
dwelling unit has water saving fixtures so 92' of leach field
will be needed based on the soils and 110 gallons per day.
The septic tank will need to be pumped again to verify
whether it is a 1000 gallon septic tank. George Drellos is not
sure if it is because it was pumped at the same time as the
main house.
11/20/18 As per my 2nd Site Inspection today I verified with
George Drellos that the septic tank is only 500 gallon. The
septic tank will also need to be replaced with a 1000 gallon
tank.
Public Sewer Sign-OffNO
Nov 20, 2018Page (1)
INSPECTION WORKSHEET (SEP-008207-2018)
Checklist ItemPassedComments
Soil Type: SandNO
Soil Type: LoamNO
Soil Type: ClayNO
Type of Water: Municipal / Well WaterNO
Waterline separation distanceNO
Well separation distanceNO
Well Casing Lengt: 50ft +/-NO
Absorbtion Fields: Total LengthNO
Septic system field above flood plainNO
Septic tanks & pump station anchored in floodNO
zone
Length of Each TrenchNO
Depth of TrenchesNO
Size of StoneNO
Seepage Pits: NumberNO
Size:NO
Nov 20, 2018Page (2)
INSPECTION WORKSHEET (SEP-008207-2018)
Checklist ItemPassedComments
Stone Size:NO
Building to TankNO
Tank to Distribution BoxNO
Distribution box to Field / PitNO
Opening Sealed:NO
End CapNO
InletOutlet Pipes & BafflesNO
Manholes 12 or less below gradeNO
[Provide extension collar if Yes]NO
Locations / SeparationsNO
Foundation to TankNO
Foundation to AbsorptionNO
Separation of PitsNO
Conforms as per Plot PlanNO
Engineer Report and As-BuiltNO
ETU Maintenance Contract providedNO
Nov 20, 2018Page (3)
INSPECTION WORKSHEET (SEP-008207-2018)
Checklist ItemPassedComments
Location of system on propertyNO
System Use StatusNO11/20/18 As per my site visit this morning I met with Mr.
Dwyer and the rep from Rotor Rooter who will camera the
septic system.
The camera revealed that there was just one Infiltrator line
approximately 25' long.
I told Mr. Dwyer he needs to install a compliant septic system
for a 2 bedroom dwelling. He said he will be contracting
George Drellos to file for permit and install system. The
dwelling unit has water saving fixtures so 92' of leach field
will be needed based on the soils and 110 gallons per day.
The septic tank will need to be pumped again to verify
whether it is a 1000 gallon septic tank. George Drellos is not
sure if it is because it was pumped at the same time as the
main house.
11/20/18 As per my 2nd Site Inspection today I verified with
George Drellos that the septic tank is only 500 gallon. The
septic tank will also need to be replaced with a 1000 gallon
tank.
O'Brien, John (Inspector)
Nov 20, 2018Page (4)