SEP-008207-2018 11202018INSPECTION WORKSHEET (SEP-008207-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0467-2018Case Module:Permit Inspection Date:Tue Nov 20, 2018Inspection Status:Failed Inspector:John O'BrienInspection Type:Septic Job Address:1232 WEST MOUNTAIN RDParcel Number:288.-1-65 Queensbury, NY 12804 Contact TypeCompany NameName ApplicantDwyer, Christopher Granted PermissionDwyer, Christopher Primary OwnerDwyer, Christopher Checklist ItemPassedComments Building Inspector NotesNO11/20/18 As per my site visit this morning I met with Mr. Dwyer and the rep from Rotor Rooter who will camera the septic system. The camera revealed that there was just one Infiltrator line approximately 25' long. I told Mr. Dwyer he needs to install a compliant septic system for a 2 bedroom dwelling. He said he will be contracting George Drellos to file for permit and install system. The dwelling unit has water saving fixtures so 92' of leach field will be needed based on the soils and 110 gallons per day. The septic tank will need to be pumped again to verify whether it is a 1000 gallon septic tank. George Drellos is not sure if it is because it was pumped at the same time as the main house. 11/20/18 As per my 2nd Site Inspection today I verified with George Drellos that the septic tank is only 500 gallon. The septic tank will also need to be replaced with a 1000 gallon tank. Public Sewer Sign-OffNO Nov 20, 2018Page (1) INSPECTION WORKSHEET (SEP-008207-2018) Checklist ItemPassedComments Soil Type: SandNO Soil Type: LoamNO Soil Type: ClayNO Type of Water: Municipal / Well WaterNO Waterline separation distanceNO Well separation distanceNO Well Casing Lengt: 50ft +/-NO Absorbtion Fields: Total LengthNO Septic system field above flood plainNO Septic tanks & pump station anchored in floodNO zone Length of Each TrenchNO Depth of TrenchesNO Size of StoneNO Seepage Pits: NumberNO Size:NO Nov 20, 2018Page (2) INSPECTION WORKSHEET (SEP-008207-2018) Checklist ItemPassedComments Stone Size:NO Building to TankNO Tank to Distribution BoxNO Distribution box to Field / PitNO Opening Sealed:NO End CapNO InletOutlet Pipes & BafflesNO Manholes 12 or less below gradeNO [Provide extension collar if Yes]NO Locations / SeparationsNO Foundation to TankNO Foundation to AbsorptionNO Separation of PitsNO Conforms as per Plot PlanNO Engineer Report and As-BuiltNO ETU Maintenance Contract providedNO Nov 20, 2018Page (3) INSPECTION WORKSHEET (SEP-008207-2018) Checklist ItemPassedComments Location of system on propertyNO System Use StatusNO11/20/18 As per my site visit this morning I met with Mr. Dwyer and the rep from Rotor Rooter who will camera the septic system. The camera revealed that there was just one Infiltrator line approximately 25' long. I told Mr. Dwyer he needs to install a compliant septic system for a 2 bedroom dwelling. He said he will be contracting George Drellos to file for permit and install system. The dwelling unit has water saving fixtures so 92' of leach field will be needed based on the soils and 110 gallons per day. The septic tank will need to be pumped again to verify whether it is a 1000 gallon septic tank. George Drellos is not sure if it is because it was pumped at the same time as the main house. 11/20/18 As per my 2nd Site Inspection today I verified with George Drellos that the septic tank is only 500 gallon. The septic tank will also need to be replaced with a 1000 gallon tank. O'Brien, John (Inspector) Nov 20, 2018Page (4)