ResCheck •
REScheck Software Version 4.6.4
Compliance Certificate
Project CHRISTOPHER DWYER
Energy Code: 2015 IECC
Location: Glens Falls, New York 288.-1-65 RC-0467-2018
Construction Type: Single-family Williams,--Tom- C;hr\S bv\1y�,�/
Project Type: New Construction �J
1232 IN Mountain Rd
Conditioned Floor Area: 1,140 ft2
Glazing Area 13% Garage Alterations 1140 s.f.
Climate Zone: 6 (7635 HDD)
Permit Date:
Permit Number:
Construction Site: Owner/Agent: Designer/Contractor:
1232 West Mountain Road Christopher Dwyer
Queensbury, NY 12804 1232 West Mountain Road
Queensbury, NY 12804
Compliance. Passes using UA trade-off
Compliance: 2.9%Better Than Code Maximum UA: 1055 Your UA: 1024
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area
Assembly or Cavity Cont. U-Factor UA
Perimeter R-Value R-Value
Ceiling 1: Flat Ceiling or Scissor Truss 1,140 38.0 0.0 0.030 34
Wall 1:Wood Frame, 16" o.c. 1,088 13.0 0.0 0.082 76
Window 1: Wood Frame:Double Pane with Low-E 105 0.310 33
Door 1: Solid 20 0.200 4
Door 2: Glass 40 0.310 12
Floor 1: Slab-On-Grade:Unheated 1,360 60.0 0.636 865
Insulation depth: 6.0'
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications,and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.4 and to comply with the mandatory requirements ' in e REScheck Inspection Checklist.
G. PETER JENSEN ��� ////O
Name-Title 17 WES I KUAIJ ignaturef Date
SOUTH GLENS FALL' / ' QED ARC
NEW YORK 1280? •Eb
(518)798-1Rcq 4uc, Ircl ER Jets,ti'�
Q cr 41 e c7 n
l 0,2602V „E-
Project Title: CHRISTOPHER DWYER �r�OF Hs*yOP Report date: 11/19/18
Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 1 of 9
wt'�. F�re, _.:.fi e.-}. r t7- '�'�C n! .'�!!. 's 'N ;, c`4
•
•
•
' t}Z L,;. e .,go� k 1..�t: .� �; <S ` '4• _ `4 gXr
•
> "'+.' :} �, 'i,.M, ,c_„ -j. .,�./ � ..
ff
,+Ft
ri:sb 59 Ek. .P?� .'' ; 7 °j` ��1�yn., i���„''•o � ''�` ' '`YxA "'f 'et•35Iq�
�aA a1R� . � i.l� � . ��¢¢
S L `C Ya Z
ems. a._ ...
•
t4
4 0 0r/
0 REScheck Software VersionChecklist 4.6.4
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
Si Req.ID
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate ❑Does Not
[PR1]' energy code compliance for the
d, building envelope.Thermal [Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]' lighting and mechanical systems. [Not Observable
„) Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
403.7 sized per ACCA Manual 5 based Btu/hr Btu/hr ❑Does Not
[PR2)2 on loads calculated per ACCA Cooling: Cooling:
42; Manual J or other methods Btu/hr Btu/hr ❑Not Observable
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: CHRISTOPHER DWYER Report date: 11/19/18
Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 2 of 9
.
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.2 Slab edge insulation R-value. R- R- ❑Complies See the Envelope Assemblies
[Foil' ❑ Unheated ❑ Unheated EDoes Not table for values.
❑ Heated ❑ Heated [Not Observable
❑Not Applicable
402.1.2 Slab edge insulation ft ft ❑Complies See the Envelope Assemblies
[FO3]1 depth/length. ❑Does Not table for values.
.1* ❑Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies
[F011]2 to protect exposed exterior ['Does Not
insulation and extends a
minimum of 6 in. below grade. ❑Not Observable
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies
[F012]2 controls installed. ❑Does Not
0' ❑Not Observable
ElNot Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: CHRISTOPHER DWYER Report date: 11/19/18
Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 3 of 9
Section Plans Verified Field Verified
Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Door U-factor. U U ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 [Not Observable
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.3.6, DNot Observable
402.5 ❑Not Applicable
[FR2]1
303.1.3 U-factors of fenestration products ❑Complies
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or
taken from the default table. ❑Not Observable
❑Not Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's ❑Does Not
instructions.
❑Not Observable
❑Not Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR2O]1 is listed and labeled as meeting ❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
or has infiltration rates per NFRC ❑Not Observable
400 that do not exceed code ❑Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies
[FR16]2 sealed at housing/interior finish ❑Does Not
and labeled to indicate 52.0 cfm
leakage at 75 Pa. ❑Not Observable
❑Not Applicable
403.2.1 Supply and return ducts in attics ❑Complies
[FR12]1 insulated >= R-8 where duct is ❑Does Not
>= 3 inches in diameter and >=
R-6 where<3 inches.Supply and ❑Not Observable
return ducts in other portions of ❑Not Applicable
the building insulated>= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.3.5 Building cavities are not used as ❑Complies
[FR15]3 ducts or plenums. ❑Does Not
❑Not Observable
❑Not Applicable
403.4 HVAC piping conveying fluids R- R- ❑Complies
[FR17]2 above 105°F or chilled fluids ❑Does Not
below 55°F are insulated to>_R-
3 ❑Not Observable
❑Not Applicable
403.4.1 Protection of insulation on HVAC ❑Complies
[FR24]1 piping. ❑Does Not
❑Not Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- ❑Complies
[FR1812 >_R-3. ❑Does Not
❑Not Observable
❑Not Applicable
403.6 Automatic or gravity dampers are ❑Complies
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts.
❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: CHRISTOPHER DWYER Report date: 11/19/18
Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 4 of 9
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: CHRISTOPHER DWYER Report date: 11/19/18
Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 5 of 9
Section Plans Verified Field Verified
Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
303.1 All installed insulation is labeled ❑Complies
[IN13]2 or the installed R-values ❑Does Not
provided.
❑Not Observable
❑Not Applicable
402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 2 of the ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall
[IN3]1 exterior,the exterior insulation Mass [1] Mass ❑Not Observable
requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. ❑Does Not
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: CHRISTOPHER DWYER Report date: 11/19/18
Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 6 of 9
Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
&Req.ID
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2, ❑ Steel ❑ Steel ❑Not Observable
402.2.6
[FI1]1 ❑Not Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. ❑Does Not
[F12]1 Blown insulation marked every
300 ftz. [Not Observable
❑Not Applicable
402.2.3 Vented attics with air permeable ❑Complies
(F122]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. [Not Observable
❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies
[F13]1 insulation .12-value of the ❑Does Not
adjacent assembly.
['Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50= ❑Complies
[F117]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8. ❑Not Observable
❑Not Applicable
403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
[FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa.For rough-in ❑Not Observable
tests, verification may need to ❑Not Applicable
occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies
[FI27]1 determine air leakage with ft2 ft2 ❑Does Not
either: Rough-in test:Total
leakage measured with a ❑Not Observable
pressure differential of 0.1 inch ❑Not Applicable
w.g.across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated ❑Complies
[F124]1 by manufacturer at<=2%of ❑Does Not
design air flow.
[Not Observable
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies
[F19]2 installed for control of primary ElDoes Not
heating and cooling systems and
initially set by manufacturer to ❑Not Observable
code specifications. ElNot Applicable
403.1.2 Heat pump thermostat installed ❑Complies
[FI10]2 on heat pumps. ❑Does Not
❑Not Observable
❑Not Applicable
403.5.1 Circulating service hot water ❑Complies
[FI11]2 systems have automatic or ❑Does Not
accessible manual controls.
❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: CHRISTOPHER DWYER Report date: 11/19/18
Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 7 of 9
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
&Req.ID
403.6.1 All mechanical ventilation system DComplies
[FI25]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air flow limits. Not Observable
❑Not Applicable
403.2 Hot water boilers supplying heat DComplies
[FI2612 through one-or two-pipe heating ❑Does Not
systems have outdoor setback
control to lower boiler water [Not Observable
temperature based on outdoor DNot Applicable
temperature.
403.5.1.1 Heated water circulation systems DComplies
[F128)2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply DNot Observable
pipe.Gravity and thermos- DNot Applicable
syphon circulation systems are
not present.Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy.Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems DComplies
[F129]2 comply with IEEE 515.1 or UL ❑Does Not
515.Controls automatically
adjust the energy input to the DNot Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that DComplies
[FI30]2 have recirculation pumps that ❑Does Not
pump water from a heated water
supply pipe back to the heated ['Not Observable
water source through a cold DNot Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 104°F.
403.5.4 Drain water heat recovery units DComplies
[F131]2 tested in accordance with CSA ❑Does Not
B55.1.Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units< 3 psi for DNot Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units< 2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent DComplies
[FI6]1 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps.
Does not apply to low-voltage :Not Observable
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have DComplies
[FI23]3 no continuous pilot light. ❑Does Not
❑Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: CHRISTOPHER DWYER Report date: 11/19/18
Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 8 of 9
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
&Req.ID
401.3 Compliance certificate posted. ❑Complies
[F17)2 ❑Does Not
['Not Observable
❑Not Applicable
303.3 Manufacturer manuals for ❑Complies
[FI1813 mechanical and water heating ❑Does Not
systems have been provided.
[Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: CHRISTOPHER DWYER Report date: 11/19/18
Data filename: C:\Users\Peter\Documents\REScheck\Chris Dwyer.rck Page 9 of 9