2008-573 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number. P20080573 Date Issued: Thursday, July 02, 2009
This is to certify that work requested to be done as shown by Permit Number P20080573
has been completed.
Location: 980 RIDGE Rd
Tax Map Number. 523400-290-010-0001-031-000-0000
Owner. TABASSUM SHEIK
Applicant: TABASSUM SHEIK
This structure may be occupied as a:
Deck By Omer of Town Board
Fireplace TOWN OF QUEENSBURY
Garage Attached %
Rusadcut+fltl�iddi�oticate of Occupancy DOES NOT relieve the
fK@§jtfttWjpptAthffesponsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
i
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20080573 Application Number. A20080573
Tax Map No: 523400-290-010-0001-03 1-000-0000
Permission is hereby granted to: TABASSUM SHEIK
For property located at: 980 RIDGE Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: TABASSUM SHEIK
980 RIDGE Rd Deck
QUEENSBURY,NY 12804-0000 Fireplace
Garage Attached
Residential Addition $90,000.00
Residential Alteration
Total Value $90,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans &Specifications
2008-573
354 sq ft residential addition 600 sq ft residential alteration 834 sq ft decks 600 sq ft garage& 1 fireplace
$278.40 PERMIT FEE PAID- THIS PERMIT EXPIRES: Thursday,November 26,2009
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at th own ::erjrday,November 26, 2008
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
;........ .......... .............'FFICEUSEONLY .-._.-_-
TAX MAP NO. � cJ 1 PERMIT NO. � ;
,
FEES: PERMI CR ATI ENGINEERING ; ;
._. (If applicable) ;
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
APPLICANT/BUILDER: etul a OWNER:
ADDRESS: 919 F'10 'Town, j P.A., ADDRESS: qa'C W1014et
PHONE NOS. 39"����2- "" S'S - Yw2 PHONE NOS.
CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: 11,,,0 (-, sf. _PHONE:
LOCATION OF PROPERTY: /l?o ko` -0
SUBDIVISION NAME:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT Z
0 w U-
APPLY TO YOUR Z F- w cn U) r w
PROJECT OO ►� ►-- Q Q. = v
w —i u_ ~ 0
H
Z Q Q � � O ~ � u~ CL3: od
SINGLE FAMILY 66
TWO-FAMILY
MULTI-FAMILY
(NO.of UNITS )
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(103) '
OTHER
l, r .
IF COMMERCIAL OR INDUSTRIAL— NAME OF BUSIWSS:
ESTIMATED CONSTRUCTION COST: 9m,a°a FUEL TYPE: at a fan t—
HEAT TYPE: Prop%,,L ''HOW MANY FIREPLACE(S):_ yet AND /OR WOODSTOVES(S):
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? ,tJ 0
IS THIS A HISTORIC SITE? Nz�
PROPOSED USE OF BUILDING OR ADDITION: �-r��'�9r S P.��� �A' --
"Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3-LGL t t-05
QTown of Queensbury - Community Development Office • 742 Bay Road, Queensbury, NY 12804
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? N d
ARE THERE EASEMENTS ON PROPERTY? N 6
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete state me nt/d escri ptio n of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to th above.
Signed
Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction
codes or septic systems)
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
.................................................... ..._ .........
Permission is hereby granted to the above This application / proposed action described
Applicant to erect or alter the building herein is found to be in accordance with the
described herein in accordance with said zoning Laws of the Town of Queensbury.
Application:
VIA
/ / /
I � / 1
o B 1, G & CODES ROYAL ; ZONING APPROVAL
o
o / ,
D DATE 01
/ 1 /
's...................................................i ...................................................J
QUESTIONS? CALL 761.8256 OR EMAIL
codesCc)-gueensbury.net
Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION
www.gueensbury.net
Operating Permit Issued: Yes No
Occupancy Type: (�:f=" QT<M
Construction Classification: yQ�
Assembly Occupancy Limit:
Special Conditions:
;> Tozvn of Qunensbury - Community Development Office • 742 Bay Road, Queensburyj, NY 12804
Check Residential Plan Review: One & Two Family Dwellings
Y/N/N/A
(2)Full sets of plans
Over 1,500 sq. ft.-Stamped
/ Design Loads On Plans: 90 Wind Floor Loads 40 psf
50 Ground Snow Load Sleeping Areas and Attics 30 psf
Calculations:
Window Schedule With Glass Size
Door Schedule/Main Entrance 36"Door
Emergency Escape Or Bedrooms and Habitable Space
/ Above/Below grade, 5.7 sq. ft.
Grade,5.0 sq. ft.
/ 24"(h)x 20"(w)min.
44"Max.Height above floor
Residential Check Paperwork Compliance and Inspectors Checklist: OK
Dampproofing/Waterproofing Materials On Plans
Foundation Drainage On Plans, if required
6"Drop in 10' Exterior Grade
Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where
Required
Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls
Platforms At Exterior Doors
Stairway Headroom 6' 8' All Stairs 36"Width
Stair Run and Rise
Winder Run and Rise
Spiral Not Allowed From 2 Story
Smoke Detectors Battery Backup and Proper Location
Bathroom Fixtures Proper Clearance
✓/ Hall Width, 36"min.
Handrails More Than Four Risers On Open Sides
-E-A9%#3G Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht.
Safety Glazing Notes For Required Areas
Garage Fire Separation
Garage Floor Sloped
^. Attic Access � L
6
Roof over 30"-22"x 30"/Crawl Spaces 18"x 24"Access
Carbon Monoxide Detector Outside Lowest Sleeping Area, On Every Level&
Interconnected
Soil Test Results, if required
Septic To Well Or Water Line Separation
All Paperwork Signed
�1 << .___
r 1 ✓ ��
- Fire Marshal`s Office
1-iccrYi of Que,nsbur - 74' Bay Road Que::Yts.mr;l, ; eu) York •1)804 -
Michael%. Paline•r, Fire N'farshal'Gary 4WI'nlan, JXvid' Fire Marshal
,
APPLICATION FOR FUEL BURNING APPLIANCE & CHIMNEYS
Application is hereby made to the Building&Codes Office for the issuance of a Building&Use Permit
pursuant to the New York State Fire Prevention &Building Code. The applicant or owner agrees to comply
with all applicable laws, ordinances,regulations,and all conditions that are part of these requirements and
also will allow all inspectors to enter premises to perform required inspections.
IMPORTANT' NOTE TO APPLICANT: ROUGH-IN AND FINAL INSPECTIONS ARE REQUIRED.
OWNER: /4 L]a S u.+, S ti k INSTALLER/BUILDER: )�au��] c(D��b.Y�n
ADDRESS: `'80 19,d e.o,40 Q u� ns6'l ADDRESS: 'a19 K
°9 Tc�Wr. 6A�O
PHONE NOS. PHONE NOS.
LOCATION OF PROPERTY- Q
SO .1h a Jel)e-0 SUBDIVISION NAME:
LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: g.-D R�9C /S mgal Q�et,,s b,�/y✓i.�y Qnz.
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: DA.v r0 T4cab5C.a, PHONE: G 3J b'S,-Z
✓ FUEL BURNING APPLIANCE WOOD COAL PELLET GAS OIL
INFORMATION
STOVE
FIREPLACE INSERT
FIREPLACE,FACTORY BUILT*
FIREPLACE,MASONRY
FURNACE{GARAGE ONLY) ,V1
*IF FACTORY BUILT,PLEASE PROVIDE: MANUFACTURER NAME: 1"1 a dS?/ MODEL NO. MI you 0v3.Lpr
LISTED BY: NUMBER:
QUESTIONS?
CALL 7614205 or 761-6206
CHIMNEY INFORMATION BLOCK BRICK STONE OR EMAIL:
fremarshalftueens bury.net
MASONRY" CHECK ONE ✓ VISIT OUR WESSITE
TILE STEEL SIZE IN FOR MORE INFORMATION
/ INCHES www.aueensbury.net
FUZE CHECK ONE ✓ V L/
DOUBLE TRIPLE WALL INSULATED DIRECT VENT CHIMNEY
WALL LINER
CHIMNEY MATERIAL CNECKONE ✓
**IF NON-MASONRY,PLEASE PROVIDE: MANUFACTURER NAME: MODEL NO.
ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION&BUILDING CODE AND/OR
MANUFACTURERS REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED
INSPECTIONS.
Queensbury Building & Code Enforcement 4R idential Final Inspection
Office No. (518)761-8256 Arrive: am/pm part: am/pm
Date Inspection request received: Inspector's Initials:
NAME: PERMIT#:
LOCATION: DATE:
TYPE OF STRUCTURE:
Commentits:
Y N A
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors _
Handrail 4 or more risers
Guards at stairs deckspatios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck porches 36 inches or more R
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Com liar
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off a used/regulator 18 inches above grade
Interior /trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Wi in stairwells safety ilialing
Interior Smoke - ors I Carbon WnoxidDet ors /
Every level: Eve Bed =v/
Outside every bedroom res:
Inter Connected: Batte bac ku :
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access 1 N.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stoppiM finished basement 1,000 sq.ft.
Ememency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum W Gypsum_
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer �...�
Duct work Sealed properly
Gas Logo in Sealed or Glass Enclosure
Final Electrical
Final SurveyPlot Plan
Arc fault Breaker in Bedrooms
Flex Gas Pipe Bonding _
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C I C or C 10 1 Temporary/Permanent
L:16uilding&Codes FormslBuilding&Codesunspection FormsWesidential Final inspection Form_revised_100405.doc;Revised
January 7,2008;Revised 6/26/08
M a_Z66ti-
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518) 761-8256 Arrive: am/am Depart: ?(C� am/pm
Date Inspection request received: inspector's Initials: ) 7�
NAME: �� ` PERMIT#:
LOCATION: Y 6 DATE: C3
TYPE OF STRUCTURE:
C en
Yes NQ N/A
4" Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Com late/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs deckspatios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed 1 regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safe I n
Interior Smoke De ors/Carbon Wnoxide etecto
Every level: Eve Bed m:
Outside every bedroo ea:
Inter Connected: Batte backu
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 sQ.ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 s .ft. �f 1
Emergency Tess below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'IV Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door doser
Duct work Sealed ro rl
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Arc Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if r uired
Okay to issue C/C or C 10 Temporary/Permanent
L:1Buiiding&Codes Forms\Building&CodesNinspection FormslResidential Final Inspection Form_revised_100405.doc;Revised
January 7,2008;Revised 6/26/08
Framing / Firestopping Inspection Repo
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm rt: • am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT#: %� _ 5-7 �
LOCATION: INSPECT ON: ZY
`�
TYPE OF STRUCTURE:
Y N NIA COMMENTS:
Framing
s 220 x 30" minimum
Jack Studs/Headers
Bracing/Bridging � ---
Joist hangers
Jadc Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 'h w 16 gauge 8 16D nails each We
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 518 inch Type X
Ceilingfwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. C
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Forms-OLDli3uilding&CodWinspedion FornaTrarning Firestopping inspection Reportdoc Revised January 7,2006
Foundation Inspection Report
Office No.(518)761-8256 Date Inspectioq,r uest received:
Queensbury Building&Code Enforcement Arrive: am/pin Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspectors Initials. _
NAME: PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Commeab
< Y N N/A
Footings a
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast?Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Fonm\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
Tmm of Qwetoskary Fire Mania
742 Barry Road
QweewdNiry,NY 12M4
761- M 1761-5206
fax 7454437
Factory Built Gas 1?"iineolaee/Stove Inspection Resort
Nebm New York State rdmres fiat aU UL Label,factory 6wilt app6amea be mAmMed a wdin#to tie mAn bommts and
iw tie Ikon NLumnal wyi■#the appEamm No deviatim f we the iawdadwt'er's
mmatnmcfiews or specs ieatiom s is amowoeA
Pam# r Sciedote InspectiAItanC1 r, l V lM
!lame � t \ Addce s t c Bowes b Fond
4*fiaoe Mamm"c weer ` L-l../ Model#
Direct Vemat Factory Ba tt Money Floe S Dowile Wa#I Triple WaH bmalated
Yes No NIA Cow
Floor Protection V/
00
Clearances to Combustibles(all sides)
Firrstop(s) Vaticd Chase V
Was rtmek aw..=„�
Vent Clearances to Combustibles
Vent/Chimney Termination of
Clvawey begM mwmm st be 3 fed above roof
pesdra6omm;2 fed above any combadibk
ewmhi ctiow Wilkie 19 feet
Gas Shut-Off Valve
Combustion Air
Hearth Extension(if any)
Mantel
Rdglit Above f1p
Witness Operation
Task Placement(if UP)
WNW-R ME Dept ydbw link-Ewe blur"
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials-
NAME: .�
PERMIT #:
LOCATION-'-- ,`� r:_ F;f = INSPECT ON: - --
TYPE OF STRUCTURE:
Y N NIA
Rough Plumbing/Nail Plates
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/H d..R
'i.S.1 for minutes
Insulation/Re 'idential Check/Commercial Check
T iIar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If r uired unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS: L
r�
Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008
Framing / Firesto Aping Inspection Report
Once No. (518)761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm Depart: a
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: LPERMIT
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
l v
-- Y N NIA COMMENTS:
('Framing
A Ic Access 27 x 30" minimum Jack Studs/Headers C,
Bracing/Bridging ✓�� ��-t'��� �"�.'�l _,
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in. i 1 "
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %W 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
6 ft. or less on center
ce and wale hield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cai(dy min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceilingfwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LASuilding&Codes Fortes-01.13113uilding&Codesmnspedion Fams\Frenft Fuetopping Inspection ReporLdoc Revised January 7,2006
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building $Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials: Z",
y
NAME: PERMIT#: God-173
LOCATION: INSPECT ON: —
TYPE OF STRUCTURE:
Y N WA COMMENTS:
Framing
ttic ss 22"x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly - -- - -
12"O.C.
Headroom 6 ft. 8 in.
StairweAs 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in. y
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceilingfwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. CM
5.7 sf above/below grade
5.0 sf grade
LABUilding&Codes Forms-OLMSuildN&CodesUropedion Fom*\Framing Faestopping Inspection Repoitdoc Revised January 7,2WO
Framing / Firestoppin nspectlon epo
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm De rt: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: ef / ` 4 PERMIT#: �
LOCATION: INSPECT ON: -
TYPE OF STRUCTURE:
— 6�h 12
r Y N A WA COMMENTS:
Framing
s 22' x 30' minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nags each side
Draft stopping 1,000 sq. ft. floor trusses �-
Anchor Bolts 6 ft. or less on center oe
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
FirBstopping
Penetration sealed Z�
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 518 inch Type X
Ceilingfwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LABuitding&Codes Forms-=\13Ui ding&CodesVrspection FomisTraming Frsdopp ft Impection Report.doc Revised January 7,2006
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart:72 am/pm
742 Bay Rd.,Queensbury,NY 12804 inspector's Initials: d
NAME: PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE: - T
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundatio ampproaa` �
Foundatio Waterproofing,,,--`
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Reportdoc
Last printed 12/20/2005 9:24:00 AM
1-3
s
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: _�
NAME: R r PERMIT#:
LOCATION: INSPECT ON: " ,
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
m
-6-niiI poly for wet areas un lab t/f y'
val
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
71
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pnu Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: rt
NAME: PERMIT# — �
LOCATION: INSPECT ON: -
TYPE OF STRUCTURE:
Common
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the con
Materi s for'this se on site.
Foundati /Wallpour
Reinforcemen ' ce
Footing Dowels or Keyway in place 10 ,
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Back ill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\lnspecdon Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
o-
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart.<q i am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: Ar / ' PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete. f
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\lnspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
2 " 4/ 7/t a f
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart-- am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
L �{NAME: 5 / PERMIT#: (/
LOCATION: 7W INSPECT ON: 12 —
TYPE OF STRUCTURE:
Commeab
Y N
Footings
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
REScheck Software Version 4.1.3
Compliance Certificate
Project Title: 100808
Report Date: 10/22/08
Data filename:Y:\\100808 SHEIKH RIDGE ROAD,QUEENSBURY.rck
Energy Code: 2007 New York Energy Conservation
Construction Code
Location: Warren County,New York
Construction Type: Detached 1I or 2 Family
Heating Type: Non-Electric
Glazing Area Percentage: 22%
Heating Degree Days: 7635
Construction Site: Owner/Agent: Designer/Contractor:
980 RIDGE ROAD TABASSUM SHEIKH JESSICA CHENIER
QUEENSBURY,NY 12804 4 MANOR DR APT B WILLIAMS&WILLIAMS DESIGNERS
QUEENSBURY,NY 12804 509 GLEN STREET
518-793-0663 GLENS FALLS,NY 12801
518-798-4687
Compliance:Passes
Compliance:20.5%Better Than Code Maximum UA:83 Your UA:66
Gross Cavity Cont. Glazing UA
Assembly Area or R-Value R-Value or D..
Perimeter U-Factor
Ceiling 1:Flat Ceiling or Scissor Truss 258 38.0 0.0 8
Wall 1:Wood Frame, 16"o.c. 415 19.0 0.0 19
Window 1:Vinyl Frame:Double Pane with Low-E 40 0.280 11
Door 1:Glass 53 0.300 16
Crawl 1:Solid Concrete or Masonry 181 0.0 11.0 12
Wall height:5.0'
Depth below grade:4.0'
Insulation depth:5.0'
Inside below-grade depth:4.0'
Furnace 1:Forced Hot Air92.8 AFUE
The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted
with this permit application.The proposed systems have been designed to meet the 2007 New York Energy Conservation Construction
Code requirements.When a Registered Design Professional has stamped and si ' age,they are attesting that to the best of his/her
knowledge,b lief,and professional'udgment,such plans or specifications area' plia ce with this Code.
ZZ
ZZ
Name-Title 1 ature Date
(�OF NE11V
� KEITH (J�
O 0
is
\ 7 5 n (LAC?
Project Title: 100808 eport date: 10/22/08
Data filename:Y:\\100808 SHEIKH RIDGE ROAD,QUEENSBURY.rck Page 1 of 4
REScheck Software Version 4.1.3
Inspection Checklist
Date: 10/22/08
Ceilings:
❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation
Comments:
Above-Grade Walls:
❑ Wall 1:Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:
Windows:
❑ Window 1:Vinyl Frame:Double Pane with Low-E,U-factor:0.280
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1:Glass,U-factor:0.300
Comments:
Crawl Space Walls:
❑ Crawl 1:Solid Concrete or Masonry,5.0'ht/4.0'bg/5.0'ext.insul/4.0'inside bg depth,R-11.0 continuous insulation
Comments:
Applies to walls of unventilated crawl spaces.
Exterior insulation has a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends
at least 6 in.below grade.
Heating and Cooling Equipment:
❑ Furnace 1:Forced Hot Air:92.8 AFUE or higher
Make and Model Number:
Air Leakage:
❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible
materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation.
Vapor Retarder:
❑ Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors,
Materials Identification:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment are identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
❑ Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building plans or specifications.
❑ Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner
that achieves the rated R-value without compressing the insulation.
Duct Insulation:
❑ Supply ducts in unconditioned attics or outside the building are insulated to at least R-11.
❑ Return ducts in unconditioned attics or outside the building are insulated to at least R-6.
❑ Supply ducts in unconditioned spaces are insulated to at least R-11.
Project Title: 100806 Report date: 10/22/08
Data filename:Y:\\100808 SHEIKH RIDGE ROAD, QUEENSBURY.rck Page 2 of 4
Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements.
Duct Construction:
All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,or
tapes.Tapes and mastics are rated UL 181A or UL 181 B.
Exceptions:
Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa).
Ll The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
Lj Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone.
Electric Systems:
❑ Separate electric meters exist for each dwelling unit.
Fireplaces:
Lj Fireplaces are installed with tight fitting non-combustible fireplace doors.
❑ Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York
State,the Residential Code of New York State or the New York City Building Code,as applicable.
Service Water Heating:
Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or
is part of a circulating system.
Lj Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
❑ Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable
sources.Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
Ll HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
Project Title: 100808 Report date: 10/22/08
Data filename:YM100808 SHEIKH RIDGE ROAD,QUEENSBURY.rck Page 3 of 4
Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non-Circulating Runouts Circulating Mains and Runouts
Heated Water Temperature(°F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-169 0.5 0.5 1.0 1.5
100-139 0.5 0.5 0.5 1.0
Table 2.Minimum Insulation Thickness for HVAC Pipes
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range(°F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0
Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD:(Building Department Use Only)
Project Title: 100808 Report date: 10/22/08
Data filename:YM100808 SHEIKH RIDGE ROAD,QUEENSBURY.rck Page 4 of 4