Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
2008-586
TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 4z Community Development- Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20080586 Date Issued: Friday, April 08, 2011 This is to certify that work requested to be done as shown by Permit Number P20080586 has been completed. Location: 15 LYNDON Rd Tax Map Number: 523400-297-006-0001-017-000-0000 Owner: JOHN & STACEE ASPLAND JR Applicant: JOHN & STACEE ASPLAND JR This structure may be occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the owner of the responsibility for compliance with Site Plan 1 ''� property P tY P � �-- bt�`� ^'� Variance, or other issues and conditions as a result of approvals by the Director of Building&Code E force Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080586 Application Number. A20080586 Tax Map No: 523400-297-006-0001-017-000-0000 Permission is hereby granted to: JOHN& STACEE ASPLAND JR For property located at: 15 LYNDON Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JOHN & STACEE ASPLAND JR 15 LYNDON Rd Residential Addition $40,000.00 QUEENSBURY, NY 12804-0000 Total value $40,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2008-586 208 sq ft res addition $75.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Thursday,November 12, 2009 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at o f Qu e be�iy; sday,November 12, 2008 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Check Residential Plan Review: One & Two Family Dwellings Y/N/N/A 2)Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 50 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade, 5.7 sq. ft. rude,5.0 sq. ft. 4"(h)x 20"(w)min. 44"Max.Height above floor VI Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofmg/Waterproofmg Materials On Plans XA- I Foundation Drainage On Plans, if required 'Drop in 10' Exterior Grade ,Vraming Cross Section For Each Roof Line, Vertical Fire Stopping Every 10' Where uired ce and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls atforms At Exterior Doors irway Headroom 6' 8' All Stairs 36"Width Stair Run and Rise Winder Run and Rise Spiral Not Allowed From 2nd Story Smoke Detectors Battery Backup and Proper Location athroom Fixtures Proper Clearance all Width, 36"min. Handrails More Than Four Risers On Open Sides Whiling and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation arage Floor Sloped Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access arbon Monoxide Detector Outside Lowest Sleeping Area, On Every Level& Interconnected Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed ................................................................................... 0....................... 3 OFFICE USE ONLY ol L— 1 _ </ +� TAX MAP NO. / PERMIT NO. FEES: PERMIT RECREATION ENGINEERING ; 10 (If applicable) ; 10 ,..................................................... PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: t�tj f 3 Tc 4 p�At, OWNER: SA#i Co ADDRESS: I S_ bl jO N k d • ADDRESS: PHONE NOS. g 3 PHONE NOS. CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: ` ,,2 (zjATTP PHONE: 3�s a a LOCATION OF PROPERTY: L4AAAl Ed. If HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION APPROVAL? ❑ YES GI/NO IF SO, INDICATE APPLICATION NO. AND DATE OF APPROVAL: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT APPLY TO YOUR Z p O C3 co PROJECT 0 0 O = _ Uu_ Tv_ _ � O _ U 0 o � OZ_ Z Q Q d N W 0 LL OF- U_ d = 06 SINGLE FAMILY TWO-FAMILY b MULTI-FAMILY (NO. of UNITS ) TOWNHOUSE I BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER kt�O�P IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST:A-gUj 0-ov FUEL TYPE: n i � �1"e2 HEAT TYPE: F,s '`wHOW MANY FIREPLACE(S): AND/OR WOODSTOVES(S): '— ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? Q0 IS THIS A HISTORIC SITE? /V d PROPOSED USE OF BUILDING OR ADDITION: kl)pSifAn:LrP *Please complete a separate Application for"Fuel Burning Appliances& Chimneys"available in our office Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 B 3-LGL 11-05 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? �c7 ARE THERE EASEMENTS ON PROPERTY? A)O I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) -------------------------------- lo This application / proposed action described o Permission is hereby granted to the above ; pp ' p p Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: ' 01 0 , ', , / ' ; ; ; BUILDING & CODES APPROVAL o ZONING APPROVAL 01 DATE ; DATE , , , QUESTIONS? CALL 761-8256 OR EMAIL codes(&-aueensburv.net Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION www.aueensbury.net Operating Permit Issued: Yes No Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: Town of Queensburyj - Cornmtinity Development Office ■ 742 Bay Road, Queensbury, NY 12804 �C � P Ar r , JJ Ij n u 5�P Queensbury BuildingA Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/pm Denart: 'MIPM Date Inspection request received: Inspector's Initials: 4ILLICT - ( NAME: PERMIT#: LOCATION: DATE: TYPE OF STRUCTUR : Comments: NO 4' Building Number Address visible from road Chimney HeWht/'B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 Indw Roof Co I Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs decks more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at decK porches 36 Inches or more Handrail Termination at Newell Post or Wall Interlor/Exterior Railings 34 inches to 38 inch Deck Brad /Handicapped Romp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Vahre shut-off /regulator 18 inches above grade Interior pdvwv I trim/doors I main entrance 36 inches Bathroom/Kitchen watertight Sa /Window in stairwells safety glazing Interior Smoke Detectors/Cartoon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Batt backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 .ft.-150 sq.ft.vents Bathroom Fans if no window Plumbina fixtures Foundation insulation/Insulation Certification Floor truss draft stopping finished basement 1,000 sq.ft. Emergency egress below grade /w Gas Furnace shut-off within 30 feet or within line of site, Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap!Water Ternp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs dosed rise>4 inches Go"Floor Pitched Garage fi roofi /%hour fire door/door closer Duct work Sealed Properly Gas Loge in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bondina As Built Se0c System/Sewer Dept. inspection Sticker Site Plan /Variance required Flood Plain Ceriification if required Okay to issue C I C or C 10 Temporay/Permanent L.\Bugding&Codes Forms\Suilding&Codes\inspection FormWesidential Final Inspection Forrr_revised_100405.doc;Revised January 7,2008;Revised WWI Queensbury Building,& Code Enforcement Residential Final Inspection t Of file No. (618)761-8256 Arrive: am/pm Depart: am/pm Date Inspection request received: _ Inspector's initials: NAME: CL ti PERMIT#: LOCATION: DATE: TYPE OF STRUCTURE: - 12 4 —"" Comments: 4" Building Number Address visible from road ���/ r /l iC- L Chimney Height r8m Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbina Vent through roof minimum 8 inches Roof Compleb/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs deckspatios more than 30 inches above arade, Guard at stairwell at 34 inches or more Guard at deckporches 38 Inches or more Handrail Termination at Newell Post or wall tnterior/Exlerior Railings 34 inches to 38 inches Deck Wacing/Handicapp2d Ramp Car► Nant Grade way from famdatlon 6 inches with 10 feet 8 inch clearance to sill pilate, Gas Valve shut-off /regulator 18 inches above grade Interior /trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Sa /Window in stairwells safety g4ft Interior Smoke Detectors I Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Bane becku Attic access 30 inches x 22 inches x 30 Inches ht in acoessible area Crawl Spaces 18 inch x 24 inch access 1 sq.1-150 sq.ft.verb Bathroom Fans if no window Plumbing fixtures Foundation insulation/Insulation Codification Floor truss draft stopping finished basement 1,000 sq.ft. Ememerw earess below arade Gas Furnace shut-off within 30 feet or within line of site ON Furnace shut-off at entrance to fumaos area Furnace/Hot Water Heater operadEs Low water shut-off boiler _ Relief Vahre s Installed/Heat Lm jg Water 1IMp 110 Enclosed Stairs Sheetrock Underside minimum IN Gymm Basement stairs closed rise>4 inches Go"Floor Pitched Garage fireproofing /%hour fire door/door doser Dud work Seated pMerly GaAJA In§@A2j or Glass Enclosure nal IeCuic;a3rl Ian Arc Fault Breaker in Bedrooms Flex Gas Pipe Bondina As Built Septic System/Sewer Deo. In on Sticker Site Plsth I Variance required Flood Plain Certification if required Okay to issue C I C or C 10 1 Temporary/Permanent LABuilding&Codes FormsWuilding&CodesUnspecdon FormsWesidential Final inspection Form_revised_100405.doc;Revised January 7,2008;Revised 8128/08 �:92 1 CIA-1-1-L-AS "AAld 01. ADV ld 0009 V . -1-1,1 A9 "1\1�d'-ILVn d0 9W011„ COMMONWEALTH ELECTRICAL YNSPIrCTION SERVICE,INC. Main Office 176 Doe Ran Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Pmait No...................... ....-..--..Cert, N2 7 13 U Cut-in Card No....-................•.............. .. Owner..............•--........ ` Location................,.<.s ........ �Yn.a.g.t....�C>.�............................... .,•. ,......................................... i Installation Consisting of :./Z asq..'41.4.4+,l,�.......... i i �u.. T-_ ...� �..s.s may✓, , .............................. .... .............. . Installed By...... .-...........................................Lie.No...................................... .... i The conditions following governed the issuance orthis certificate,and any certificate previously issued is cancelled.,- This certificate only covers the electrical equipment and installation conditions as of date. U • in ,°{�o a ate ui c o% t n , �Q o ection. t Ct pcEto9tj of Company )VM p—nvvriryleg�ma�ting tnsp tits att'an uni and i ruses are violated,the C'ompar� i I{tiga<ettt � cc t a . l�T A A O� /1u1 1 a 1�1L V 1 .............. INSPECTOR...... ....... .... .... .................. Member N.F.P.A,I.A.E.I. TO 39dd 0-igwnW NOd P8918GL 00:9T TTOZ/b0/b0 1w ;L; yd;/-- �--10 &A-- Queensbury Building & Code Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: am/pm Depart:T am/pm Date Inspecti re est r ived: t0 l inspector's Initials: NAME: PERMIT#: - LOCATION: ;M1 DATE: TYPE OF S RUCTURE: � ,F _ Comments: Q Yss N NIA_ 4" Buildingro Number Address visible from ad Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers __ Guards at stairs,decks, ati®s mare than 30 inches above grade Guard at stairwell at 34 inches or more ' Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall AZ Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above 2rade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen waterti ht Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 s .ft.vents Bathroom Fans,if no window u a fixtures FPlumbing L�\� Foundndation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 s .ft. Emergency egress below grade `-�.Cy' Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area v, Fumace/Hot Water Heater operating Low water shut-off boiler , Relief Valves installed/Heat Trap/Water Temp 110 �✓/� �` � Enclosed Stairs Sheetrock Underside minimum'A"Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required - Flood Plain Certification,if required Okay to issue C/C or C 10 1 Temporary/Permanent L:\Building&Codes Forms\Building&CodeMinspection Forms\Residential Final Inspection Form_revised_100406.doc;Revised January 7,2008;Revised 6/26/08 z a©j 7 Rough Plumbingfnsu ation Ins coon Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:C--' -%/ NAME: / PERMIT#: D -- LOCATION: INSPECT ON: / -® TYPE OF STRUCTURE: Y N NIA Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washina Machine Drain 2 inch minimum anout every 0 feet/change of direction Pressure Te m ent Air/ 10V . above highest connection for 15 minutes Pressure Test,/ PPIy Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing insulation Report revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Report v r l� -�-- Office No. (518)761-8256 Date Inspection request received: ►2 `�/�'`S Queensbury Building &Code Enforcement Arrive: am/pm Depart: i am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: � � ` '� � PERMIT#: - LOCATION: _=q11 :L f j INSPECT ON: U TYPE OF STRUCTURE: _., Y N WA COMMENTS: Attic Access 22" x 3Y minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq.ft floor trusses Anchor Bolts 6 ft. or less on enter Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hair Fire wall 2, 3, 4 hour irestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 518 inch Type X Ceiling1wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. W 5.7 sf above/below grade 5.0 sf grade LABuiidirg&Codes Formsd31.13\13uitdi V&CodeMinspedion FomesTrarnirg Firestopping Inspection Report doc Revised January 7,2008 lb - it Rough Plumbing l Insulation Inspection Report kz- Office No. (518) 761-8256 Date Inspection request received: � LIt� Queensbury Building &Code Enforcement Arrive: am/prn art: - am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: � S � ' � PERMIT ##: C> LOCATION: _/�, w•. i2 INSPECT ON: 2 `�- TYPE OF STRUCTURE: VLt 1 Y N N/A Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/char a of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 fit. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes nsulation/Residential Check/Commercial Check I Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: k'�A Rough Plumbing Insulation Report,revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Report ' Office No. (518)781-8256 Date Inspection request received: / —Z' )- ok Queensbury Building &Code Enforcement Arrive: am/pm Depart:jj - m/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: Ar d1� PERMIT#: ( �_ �' ,A LOCATION: INSPECT ON: _L, Z.�� TYPE OF STRUCTURE: YZ N WA�'Framing 00, COMMENTS Attic Access 220 x 3W minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12'O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Wails Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq.ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X CeiringNTII Windows Habitable Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Fortes-OLDISuNci ft&CodesMnspection FornisTrarning Firestopping Inspection Repatdoc Revised January 7,2008 Framing / Firestopping InspectionAeport Office No. (518)761-8256 Date Inspection request received:_ Queensbury Building &Code Enforcement Arrive: am/ Depart: I,am/pm 742 Bay Road, Queensbury, NY 12604 Inspector's Initials: r , NAME: PERMIT#: (ca LOCATION: _ INSPECT ON: TYPE OF STRUCTURE: Y N WA COMMENTS: Framing ,, ss 22" x 30" minimum Jack Studs/Headers F7vt�' ` f Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. .---..._�_ Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. �._._.. . ... .,_A yr --__ �-ems Notches/Holes/Bearing Walls + Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side .- Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilingtwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (V1/) 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Forms-OLD\BuikWV&Codesdnspedion FornIsT aening Fusstopping inspection RepoR.doc Revised January 7,20W Framing / Firestopping Inspection Report r 1 �I U U 1 Office No. (518)761-8256 Date Inspection request received: Z Queensbury Building &Code Enforcement Arrive: am/= Depart: 1 am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's initials: NAME: �, P - _ - PERMIT#. Y � LOCATION: T <� c �► INSPECT ON: 2 r TYPE OF STRUCTURE: _ C � Framing Y N NIA COMMENTS Attic Access 220 x 3V minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12° O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Wails Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 518 inch Type X Ceiling1wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (" 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Forms-OLDBuiiding&Codesdnspection FomisTrarning Firestopping Inspection Report.cbc Revised January 7,2006 Foundation Inspection Report Office No.(518)761-8256 Date Inspecttrequegst Queensbury Building&Code Enforcement Arrive: h D art:742 Bay Rd.,Queensbury,NY 12804 Inspector's � NAME: Asio PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: _ Comm n Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement the concrete. &1��Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width nc a hove footing 1 po1 r wet areas under slab Bac -Elumbitrg"Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Fonms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Foundation Inspection Report Office No. 518 761-8256 Date Ins{ ) Inspection request received: 1 Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: n � NAME: PERMIT#: � LOCATION: 15 L�/� G - i INSPECT ON: Z TYPE OF STRUC Comments Y N N/A tings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place { Footing Dowels or Keyway in place �} Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\lnspection Forms\Faundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM REScheck Software Version 4.2.0 Compliance Certificate Project Title: JOHN AND STACEE ASPLAND Energy Code: 20001ECC Location: Glens Falls,New York Construction Type: Single Family Glazing Area Percentage: 15% Heating Degree Days: 7635 Construction Site: Owner/Agent: Designer/Contractor: 15 LYNDON ROAD QUEENSBURY,NY ,Compliance: Compliance:5.3%Better Than Code Maximum UA:57 Your UA:54 Gross Cavity Cont. Glazing UA Assembly Area or R-Value R-Value or D.. Perimeter U-Factor Ceiling 1:Flat Ceiling or Scissor Truss 208 38.0 0.0 6 Wall 1:Wood Frame, 16"o.c. 380 21.0 0.0 17 Window 1:Wood Frame:Double Pane with Low-E 15 0.350 5 Door 1:Glass 42 0.350 15 Door 2:Solid 19 0.100 2 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 208 21.0 0.0 9 Boiler 1:Other(Except Gas-Fired Steam)80 AFUE Air Conditioner 1:Electric Central Air 13 SEER Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 4.2.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. G Al2l l-I-ckG K Es Di2AFzs him 1 d 27 -c8 Name-Tide Signature Date Project Title:JOHN AND STACEE ASPLAND Report date: 10/27/08 Data filename: Untitled.rck Page 1 of 4 t 4 CREScheck Software Version 4.2.0 VJ Inspection Checklist Ceilings: ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame,16"o.c.,R-21.0 cavity insulation Comments: Windows: ❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?—Yes No Comments: Doors: ❑ Door 1:Glass,U-factor:0.350 Comments: ❑ Door 2:Solid,U-factor:0.100 Comments: Floors: ❑ Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-21.0 cavity insulation Comments: Heating and Cooling Equipment: ❑ Boiler 1:Other(Except Gas-Fired Steam):80 AFUE or higher Make and Model Number. ❑ Air Conditioner 1:Electric Central Air:13 SEER or higher Make and Model Number: Air Leakage: ❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation. Vapor Retarder: ❑ Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: ❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications. ❑ Insulation is installed according to manufacturers instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: ❑ Ducts in unconditioned spaces are insulated to at least R-5.Ducts outside the building are insulated to at least R-8.0. Duct Construction: Project Title:JOHN AND STACEE ASPLAND Report date: 10/27/08 Data filename: Untitled.rck Page 2 of 4 All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,or tapes.Tapes and mastics are rated UL 181 A or UL 181 B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). The HVAC system provides a means for balancing air and water systems. Temperature Controls: Lj Thermostats exist for each separate HVAC system.A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor is provided. Service Water Heating: Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. 0 Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: Lj Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: Lj All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depietable sources.Pool pumps have a time clock. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Project Title.JOHN AND STACEE ASPLAND Report date: 10/27/08 Data filename: Untitled.rck Page 3 of 4 t Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" Temperature("F) 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2:Minimum Insulation Thickness for HVAC Pipes insulation Thickness in Inches by Pipe Sizes Fluid Temp. 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Piping System Types Range("F) Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.6 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Project Title: JOHN AND STACEE ASPLANDI Report date: 10/27/08 Data filename: Untitled.rck Page 4 of 4