Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
blower door results --28
Testing Company: Name:LoCascio Energy Solutions Address:20 Ogden Rd. Queensbury , NEW YORK 12804 Phone: 5188573144 Technician: Name:Anthony LoCascio Credentials:HERS Rater#4242961 Email:tony@locascioenergysolutions.com Building Information: Project ID:28 Wedge Address:28 Wedgewood -A Queensbury, NY 12803 Geo-Tag Data:Latitude: 43.326088 Longitude: -73.685105 Timestamp: 2020-02-12 12:31:28 Customer Information: Name:Schermerhorn Address:Queensbury, NY 12804 Measured Leakage:640.8 CFM50 Test ID:28 Wedgwood Purpose of Test:RESNET Multi-Pt Env. Leakage Measured ACH50:3.43 (+/- 4.0%)Effective Leakage Area: 31.3 in² Building Volume:11,223.0 ft ³Enclosure Surface Area: 1,247.0 ft² Flow Coefficient (C):42.0 (+/- 13.6%)Exponent (n): 0.697 (+/- 0.040) Correlation Coefficient:0.99951 Test Standard:RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 68 °F Altitude: 457.0 ft Outdoor Temp: 33 °F Time Average Period: 10 seconds Test Date and Time:2020-02-12 14:11:22 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -4.5 -60.0 -63.8 -59.3 -174.7 783.3 Ring B -48.0 -54.9 -50.4 -130.1 677.0 Ring B -35.0 -38.6 -34.1 -74.5 513.6 Ring B -23.0 -26.9 -22.4 -45.1 400.3 Ring B -10.0 -10.9 -6.4 -52.4 162.9 Ring C Test Equipment: Flow Device:Model 3 110V Fan Serial #: 3172 Pressure Gauge:DG1000 Serial #: 3172 Calibration Date: 2019-02-18 Deviations from Standard: None Comments: Envelope Leakage Test (Page 2) Report generated by TEC Auto Test version 1.6.3 (2), © 2019 by The Energy Conservatory, Inc.