Loading...
blower door results -- 26Testing Company: Name:LoCascio Energy Solutions Address:20 Ogden Rd. Queensbury , NEW YORK 12804 Phone: 5188573144 Technician: Name:Anthony LoCascio Credentials:HERS Rater#4242961 Email:tony@locascioenergysolutions.com Building Information: Project ID:26 wedge Address:26 Wedgewood Queensbury, NY 12804 Geo-Tag Data:Latitude: 43.326122 Longitude: -73.685098 Timestamp: 2020-02-12 12:35:19 Customer Information: Name:Schermerhorn Address:536 Bay Rd Queensbury, NY 12804 Measured Leakage:415.9 CFM50 Test ID:26 Wedgwood Purpose of Test:RESNET Multi-Pt Env. Leakage Measured ACH50:2.37 (+/- 7.2%)Effective Leakage Area: 21.5 in² Building Volume:10,530.0 ft³Enclosure Surface Area: 1,170.0 ft² Flow Coefficient (C):29.7 (+/- 34.7%)Exponent (n): 0.675 (+/- 0.099) Correlation Coefficient:0.99680 Test Standard:RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 61 °F Altitude: 424.0 ft Outdoor Temp: 33 °F Time Average Period: 10 seconds Test Date and Time:2020-02-12 14:34:15 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -1.9 -60.0 -62.2 -60.3 -72.5 506.5 Ring B -48.0 -49.7 -47.8 -52.3 430.8 Ring B -35.0 -36.9 -35.0 -33.5 345.3 Ring B -23.0 -25.8 -23.9 -123.1 252.6 Ring C -10.0 -14.3 -12.4 -61.7 177.3 Ring C Test Equipment: Flow Device:Model 3 110V Fan Serial #: 3172 Pressure Gauge:DG1000 Serial #: 3172 Calibration Date: 2019-02-18 Deviations from Standard: None Comments: Envelope Leakage Test (Page 2) Report generated by TEC Auto Test version 1.6.3 (2), © 2019 by The Energy Conservatory, Inc.