2008-633 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building& Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20080633 Date Issued: Monday, June 20, 2011
This is to certify that work requested to be done as shown by Permit Number P20080633
has been completed.
Location: 19 CAITLIN Dr
Tax Map Number: 523400-301-017-0003-048-000-0000
Owner: KELACO, LLC
Applicant: KELACO, LLC
This structure may be occupied as a:
Residential Alteration By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20080633 Application Number. A20080633
Tax Map No: 523400-301-017-0003-045-000-0000
Permission is hereby granted to: KELACO, LLC
For property located at: 888 SHERMAN Ave
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: KELACO, LLC Residential Alteration $110,000.00
35 FRONT St Total Value $110,000.00
LAKE GEORGE,NY 12845-0000
Contractor or Builder's Name/ Address Electrical Inspection Agency
Plans &Specifications
2008-633
2722 sq ft residential alteration
$272.20 PERMIT FEE PAID- THIS PERMIT EXPIRES: Thursday,December 10, 2009
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the f Que bury; Wednesday,December 10,2008
SIGNED BY for the Town of Queensbury.
Director of Buil g& e Enforcement
----------- -------
Fire Nlav,;hal's Office
-1 0um of,,_)I/C:C11S1'11 I'll/ - '42 Pay Road Qiwenslyitrq, New York -12804
JYJiCIIIRJ j. Pahncr,, Firt,Alar5lhd - '_Irl/ShIltnan, DePitt'll Fire Alarshal
--------------- ------
APPLICATION FOR FUEL BURNING APPLIANCE & CHIMNEYS
Application is hereby made to the Building&Codes Office for the issuance of a Building & Use Permit
pursuant to the New York State Fire Prevention &Building Code. The applicant or owner agrees to comply
with all applicable laws, ordinances,regulations, and all conditions that are part of these requirements and
also will allow all inspectors to enter premises to perform required inspections.
IMPORTANT NOTE TO APPLICANT: ROUGH-IN AND FINAL INSPECTIONS ARE REQUIRED.
OWNER: C-0 U C, INSTALLER/BUILDER: . Co 11,P#P
ADDRESS: b LJ, PtZ- !;4(-kInAA) ADDRESS: Q2 LA-)- •
PHONE NOS. PHONE NOS. v 6 I a D 65 519--1,
LOCATION OF PROPERTY: "(UV'PjZ_ V J?RPIL SX111ZAAA1 f'SUBDfVISION NAME:
LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: SAI&tb
.12
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: 16111, 6611e^ —PHONE: ,5
✓ FUEL BURNING APPLIANCE WOOD COAL PELLET GAS OIL
INFORMATION
STOVE
FIREPLACE INSERT
FIREPLACE,FACTORY BUILT*
FIREPLACE,MASONRY
FURNACE(GARAGE ONLY)
*IF FACTORY BUILT,PLEASE PROVIDE: MANUFACTURER NAME: MODEL NO.
LISTED BY: NUMBER:
QUESTIONS?
CALL 7614205 or 761-6206
CHIMNEY INFORMATION BLOCK BRICK STONE OR EMAIL:
firemarshal@gueensbury.net
MASONRY" CHECK ONE ✓
VISIT OUR WESSITE
✓TILE STEEL SIZE IN FOR MORE INFORMATION
INCHES www.queensburv.ne
FLUE CHECK ONE ✓
DOUBLE TRIPLE WALL INSULATED DIRECT VENT CHIMNEY
WALL LINER
CHIMNEY MATERIAL CHECK ONE ✓
**IF NON-MASONRY,PLEASE PROVIDE: MANUFACTURER NAME: MODEL NO.
ADDITIONAL NOTE: CONSTRUCTION/INSTALLATION MUST CONFORM TO NYS FIRE PREVENTION&BUILDING CODE AND/OR
MANUFACTURERS REQUIREMENTS. CONSULT AVAILABLE TOWN OF QUEENSBURY HANDOUTS REGARDING REQUIRED
INSPECTIONS.
Check Residential Plan Review: One & Two Family Dwellings
YA/N/A
(2)Full sets of plans
Over 1,500 sq. ft.—Stamped
Design Loads On Plans: 90 Wind Floor Loads 40 psf
50 Ground Snow Load Sleeping Areas and Attics 30 psf
f' Calculations:
Window Schedule With Glass Size
Door Schedule/Main Entrance 36"Door
Emergency Escape Or Bedrooms and Habitable Space
t Above/Below grade, 5.7 sq. ft.
Grade,5.0 sq. ft.
24"(h)x 20"(w)min.
44"Max.Height above floor
,Residential Check Paperwork Compliance and Inspectors Checklist: OK
Dampproofmg/Waterproofing Materials On Plans
Foundation Drainage On Plans, if required
6"Drop in 10' Exterior Grade
Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10' Where
Required
Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls
Platforms At Exterior Doors
Stairway Headroom 6' 8' All Stairs 36"Width
Stair Run and Rise
,Winder Run and Rise
Spiral Not Allowed From 2° Story
Smoke Detectors Battery Backup and Proper Location
Bathroom Fixtures Proper Clearance
Hall Width, 36"min.
Handrails More Than Four Risers On Open Sides
' Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht.
Safety-Glazing Notes For Required Areas
Garage Fire Separation
Garage Floor Sloped
Attic Access
Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access
Carbon Monoxide Detector Outside Lowest Sleeping Area, On Every Level&
Interconnected
Soil Test Results, if required
Septic To Well Or Water Line Separation
All Paperwork Signed
-? --1-- ------------------ OFFICE USE ONLY_---._. .--- -_--_ r i
r .? d
- ; i ) ��
TAX MAP NO. PERMIT NO. t ;
Z:- ; ,,
oo FEES: PERMIT /- ` RECREATION ENGINEERING N01 � $
(If applicable) 0
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
APPLICANT/BUILDER: (0tL-[L�e (,Atj.tf OWNER: F.N lAco /
ADDRESS: 6 "VefLShtJj1 Ib � • ADDRESS: Sr -
PHONE NOS. 1l;LJ '� � '�- PHONE NOS.
CONTACT PERSON FOR BUILDING &CODFS COMPLIANCE: (<PAL.) Celle77r PHONE:
LOCATION OF PROPERTY: �? 2&e= ?yte/t e'y
HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION APPROVAL? ❑ YES I3"'NO
IF SO, INDICATE APPLICATION NO. AND DATE OF APPROVAL:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT ZO o
APPLY TO YOUR Z 0 cn rnw
PROJECT OC 0 u uj _ a.
, O F.: _
L� o LLCM °z C� F- H 0E- � LLZ
Z Q Q V7 N U) O LL E- U-
SINGLE FAMILY / 7 3� jq U — ;) ;a 3q
TWO-FAMILY V /
MULTI-FAMILY
(NO.of UNITS )
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(1,2,3)
OTHER
IF COMMERCIAL OR INDUSTRIAL- NAME OF BUSINESS:
ESTIMATED CONSTRUCTION COST. 4110 00 FUEL TYPE: 4AS
HEAT TYPE: god"" a t{'� *HOW MANY FIREPLACE(S): AND/ OR WOODSTOVES(S) r
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE?
IS THIS A HISTORIC SITE? AM --
PROPOSED USE OF BUILDING OR ADDITION: pse
`Please complete a separate Application for"Fuel Burning Appliances& Chimneys"available in our office
Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804
B 3-LGL 1]-05
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? kc?
ARE THERE EASEMENTS ON PROPERTY? /`•-�-
I acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete statement/description of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above.
Signed
Director of Building& Codes: 761-8256 (for questions regarding Building Permits, construction
codes or septic systems)
Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
--------------------------------------------
Permission is hereby granted to the above This application / proposed action described
Applicant to erect or alter the building ; herein is found to be in accordance with the
described herein in accordance with said 0 zoning Laws of the Town of Queensbury.
Application: - ,
0 1 /
0
/00 10
,
BUILDING & CODES APPROVAL ; , ZONING APPROVAL
01
DATE
DATE
0 ,
, - -
____________________________________________________- :_.__.___._.___._._.._
QUESTIONS? CALL 761-8256 OR EMAIL
codes(M-gueensburv.net
Office Use OnIV VISIT OUR WEBSITE FOR MORE INFORMATION
www.aueensbury.net
Operating Permit Issued: Yes No
Occupancy Type: Construction Classification:
Assembly Occupancy Limit: Special Conditions:
Towri of Queensbury - Conimunihf Development Office - 742 Bay Road, Queensbury, NY 12804
0
Queensbury Building & Code Enforcement - Residential Final Inspection
2
Office No. (518) 761-8256 Arrive: am/p art: am/pm
Date Inspection request received: Inspector's Initials.
NAME: PERM T#:
LOCATION: DATE:
TYPE OF STRUCTUR :
Comments:
Yes No N/A
4" Building Number Address visible from road � bs-e-
FreshChimne Hei ht/"B"Vent/Direct Vent Location 0 Air Intake ll// 111 \\\
3 inch Plumbing Vent through roof minimum 18 inches `
Roof Complete/Exterior Finish Complete (�C
Platform at all exterior doors O �+ l
Handrail 4 or more risers
Guards at stairs decks, patios more than 30 inches above grade SUIVII
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall ��
Interior/Exterior Railings 34 inches to 38 inches t
Vj
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification/Sticker on Panel
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'/"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
71
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C 10 Temporary/Permanent
LABuilding&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised
January 7,2008; Revised 6/26/08; Revised 12/22/10
Queensbury Building & Code Enforcement - Residential Final Inspection
O r No. (518) 761-8256 Arrive: am/pm Depart:l am/pm
Date Inspection request received: inspector's Initials: Alm
NAME: r C PERMIT#:
LOCATION: S,sr DATE:
TYPE OF STRUCTURE:
Commends•
N NIA )z_ /f1Cr°
C`
4' BuildingNumber Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers ^
Guards at stairs deckspatios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inures or more
Handrail Termination at Newell Post or Wail
interior/Exterlor Railings 34 inches to 38 inches
Deck Bract /Handica Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off sed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches ' �—
Bathroom/Kitchen watertight
SaLeA glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors 1(
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access 1 .ft.-150 sq.ft.vents
Bathroom Fans if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency ress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stains Sheetrock Underside minimum W Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing I%hour fire door/door closer
Duct work Sealed properly
Gas Logo in Sealed or Glass Enclosure
Final Electrical _
Final Survey Plot Plan
Arc Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic Sy stem I Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C 10 Temporary/Permanent
LABuilding&Codes FormslBuilding&Codes\lnspection FormsWesidential Final Inspection Fomr_revised_100405.doc;Revised
January 7,2008;Revised 6/26/08
r
Queensbury Building & Code Enforcement - Re ' ential Final Inspection
-_NN
Office No. (518) 761-8256 Arrive: am/pm Departt,,_i: m/pm
ate Inspection request received: Inspector's Initials:
NAME: PERMIT#:
LOCATION: DATE:
TYPE OF STRUCTU E: f 9 Ff A crr-a--
Comments
WA
4' Building Number Address visible from road y�
Chimney Height i'B'Vent/Direct Vent Location ��= J
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches L
Roof Complete/Exterior Finish Complete
Platform at all exterior doors _
Handrail 4 or more risers
Guards at stairs decks ethos more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck porches 36 inures or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feetIN
6 inch clearance to sill plate
f:/�� "`'�
Gas Valve shut-off!Lxposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Saglazing/W' dow in stairwells safety glazing
Interior Smoke 96tectors/Carbon M oxid etectors
Every level: Ev Bed_ ro0.
Outside every bedroom res: 01
4�✓'
Inter Connected: Batts badku
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access i N.ft..-1 50 sq.ft.vents
Bathroom Fans,if no window s
fixtures FPlumbing
Foundndation insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency ress below grade -
Gas Furnace shut-off within 30 feet or within line of site .-
Oil Furnace shut-off at entrance to fumace area
Fumace/Hot Water Heater opprating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrodc Underside minimum IN Gypsum
Basement stairs dosed rise>4 inches
Garage Floor Pitched 01
Garage fireproof I'/+hour fire door/door doser j---t A4
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical j
Final Survey Plot Plan _
Arc Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Ins ion Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C 10 Temporary/Permanent
�w
LABuilding&Codes FormslBuilding&Codesunspection FornsWesidential Final inspection Forn_revised_100405.doc;Revised
January 7,2008;Revised W6108
Septic Inspection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Rd., Queensbury, NYI 12804 Inspector's Initials:6t-
NAME: lGcCO PERMIT NO.:
LOCATION: INSPECT ON:
RECHECK:
Comments and/or diaciram
Soil T Loam/ Clay
Type of Water: u i ' I/ Well Water �"
le
Waterline se aration distance ft.
Well separation distance ft.
Other wells: ft.
Well Casing Length 50' + - Y N N/A
Absorption Field; Total length 'L- ft.
Length of each trench ft.
Depth of trenches L22 1Z_k'
Size of Stone 2-
Seepage Pits: Number
Size:
Stone Size:
Piping Size Type
Building to tank
Tank to Distribution Box
Distribution Box to Field Pit
Opening Sealed: N
End Cap VY N
Inlet/Outlet Pipes&Baffles Y N -7,
Location/ Separations
Foundation to tank ft.
Foundation to absorption ft.
Separation of Pits ft.
Conforms as per Plot Plan Ye N
E nd As-Built Y N
Location of System on Property:
Front Rear Left Side Right Side Middle Front Middle Rear
Svstem Use S
__Approved
Partial Approved and needs to be re-inspected, please call the Building &Codes Office
Disapproved
Last revised 06/18/07 U\Building&Codes Forms-OLD\Building&Codes\Inspection Forms\Septic Inspection Report.doc
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection uff �l
Queensbury Building & Code Enforcement Arrive: Z a : = S a�
742 Bay Road, Queensbury, NY 12804 inspector's Initial .
NAME: V.R- It4 C U L LC PERMIT #: C� '
LOCATION: INSPECT ON: U
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbing /Nail Plates
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S.1 for 15 minutes
nsulation/Residential Check/Commercial Check
�Tyyek or Similar Exterior Sealant 4
r-
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008
Rough Plumbing / Insulation 1 pection Report
Office No. (518) 761-8256 Date Inspection req _'
Queensbury Building & Code Enforcement Arrive: <�[7 a p art: .7" an9'J'°"
742 Bay Road, Queensbury, NY 12804 Inspector's Initia /
NAME: /aco PE #:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
Rough Plumbing /Nail Plates
Plumbing Vent/Vents in Place
1 %inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S.1 for 15 minutes
/Residential Check/Commerci heck
T ek or Pimilar Exterior Sealant ts,`._..
ent, Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If Leguired unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation Report revised Nov 17 2003, revised February 15,2005, revised January 7,2008
v�S
Rough Plumbing / Insulation Ins ection Report
Office No. (518) 761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: —am/pm Depart: am/pm
742 Bay Road, Queensbury, NY 12804 inspector's Initials:
NAME: PERMIT#:
LOCATION: INSPECT ON: 2
TYPE OF STRUCTURE:
Y N NIA
Rough Plumbing / Nail Plates
Plumbing Vent/Vents in Place
1 % inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain /Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
'5 . or 15 minutes
Insulation Residential Check/Commercial Check
T Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
uct work sealed properly/No duct tape
COMMENTS.
Rough Plumbing Insulation Reportrevised Nov 17 2003, revised February 15,2005, revised.January 7,2008
Framing / Firestopping Inspection Report
1 - 3
Office No. (518)761-8256 Date inspectjprt ed:
Queensbury Building &Code Enforcement Arrive: part: '222 am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's In' .
NAME:_ 'O( C.._ET 1 E ERMIT#:
LOCATION: (o k _K AE VER A� A") NSPECT ON: —
TYPE OF STRUCTURE:
.z
Y N NIA COMMENTS,*
M
Attic Access 22"x 30" minimum
Jack Studs/Headers
Bracing/Bridging \C—
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C. FV-DOk
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
re,separation 1, 2, 3 hour
vvatl 2, 3, 4 hour
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling1wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (V1f)
5.7 sf above/below grade
5.0 sf grade
LABuiidmg&Coded Fortes-=\Building&CodesUrapedion FomisTraming FkntopphV Irapedion Reportdoc Revised Januaq 7,2006
0 Z �.
Framing / Firestopping Ins ion Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building &Code Enforcement Arrive: am/pm Depart: P> c am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE: .
Y N/A COMMENTS:
Framing
AWC'Access 22" x 30" minimum
Jack Studs/Headers 491
Bracing
/Bridging v
Joist hangers ��{Z
Jack Posts/Main Beams
Exterior sheeting nailed properly
12A O.C. �F _ -
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing -Z
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/W 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
r1V
Fire separation 1, 2, 3 hour
Fi 2, , 4 hour
Firestopping
sealed
16 inch insulation in Cavity min.
Garage Fire Separation
House side%inch or 518 inch Type X
Garage side 518 inch Type X
Ceilingfwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Forms-OLMSuilding&CodesVnspection Fo m Tmrr irp Firestopping Irspedion Report doc Revised January 7,2008
�v-/j pr'\
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: 7A/ o/1
Queensbury Building & Code Enforcement Arrive: am/pm Depart: Z- G CL.y am/pm
742 Bay Road, Queensbury, NY- 12804 Inspector's Initials
NAME: C � PERMIT
LOCATION: INSPECT ON: 1 lS
TYPE OF STRUCTURE:
Y N N/A
Rou h P n /Nail Plates
Plumbing Vent/Vents in Place
1 h inch minimum Drain Size
Washing Machine Drain 2 inch minimum
Cleanout every 100 feet/change of direction
Pressure Test
Drain/Vent
Air/Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
Pressure Test
Water Supply Piping
Air/Head
50 P.S.I for 15 minutes
Insulation/Residential Check/Commercial Check
Tyvek or Similar Exterior Sealant
Proper Vent, Attic Vent
Door/Window Sealed No Insulation
Duct/ Hot Water Piping Insulation
If r uired unheated Maces
Combustion Air Supply for Furnace
Duct work sealed properly/No duct tape
COMMENTS:
Rough Plumbing Insulation Report revised Nov 17 2003, revised February 15,2005, revised January 7,2008
Framing / Firestopping Inspection eport
Office No. (518)761-8256 Date In request received:
Queensbury Building&Code Enforcement Arrive: am/ Depart: am/pm
742 Bay Road, Queensbury, NY 12804 inspector's Initials:-
NAME: co _ PERMIT#. �/F—Ir I/C
LOCATI INSPECT ON:
TYPE OF STRUCTURE:
Framing Y N N/A COMMENTS
Attic Access 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
ft. or less on center
Ice and water sh Id 24 inches from wall
ion 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 518 inch Type X
Garage side 518 inch Type X
Ceiling1wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. OM
5.7 sf above/below grade
5.0 sf grade
L:Suilding&Codes Forms-OMBuild ft&CodesUnspection FomaT arning Firestopping Inspection ReporLdoc Revised January 7,2006
Framing / restopping Inspection Recgo�r,req po
Office No. (518)761-8256 Date Inspeuest received:
Queensbury Building&Code Enforcement Arrive:7-�L am/pm part:,�am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:
NAME: PERMIT#:
LOCATION: INSPECT ON: �.
TYPE OF STRUCTURE:
Framing Y N NIA COMMENTS•
Attic Access 22"x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 % w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
6 ft. or less on center _
Ice and water hield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side h inch or 518 inch Type X
Garage side 518 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. i;W)
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Fortes-OLD WIding&CodesUnspedion FamsTnin ing Fi estoppft Inspection Reporidoc Purvised January 7,2008
S�/lJ / urs
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date InWec bop request received:
Queensbury Building &Code Enforcement Arrive:��� am/prr,� Depart: am/pm
742 Bay Road, Queensbury, NY 12804 Ins ctor's nit—ials: 1
NAME: F/ry C a PERMIT#: ( J
LOCATI INSPECT ON:
TYPE OF STRUCTURE:
Framing Y N N/A COMMENTS:
Attic Access 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12" O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %W 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft floor trusses
Bolts . or less on center
Ice and water s 24 inches from wall
on 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side', inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling1wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. K
5.7 sf above/below grade
.0 sf grade
LABuilding&Codes Forms-=\Building&CodesNnspedion FoiryWt rxnp Fires ny Inspedan Reporicioc R®used January 7,2006
Z
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/p Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT#: `r
LOCATION: °INSPECT ON:
TYPE OF STRUCTURE:
Commemb
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
Qnwh�ove footing
mi poj r wet areas under sla t "�--
Backfill App al
-flun*inonder Slab
PVC/Cast/Copper GG�
Foundation Insulation Interior/Exterior `
R-
Rough Grade 6 inch drop within 10 ft. T-1
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspecction Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(518)761-8256 Date Ins on req ve
Queensbury Building&Code Enforcement Arrive: Dep : am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initi -
NAME: ERMIT#: O�- J 3 _
LOCATION: INSPECT ON:
TYPE OF STRUCTURE: r r
COMMen
Y N N/A
Footin
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
3 '7/110r�
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&t Code Enforcement Arrive: am/pm Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: U
NAME: PERMIT CQ �r )
T#:
LOCATION: V� INSPECT ON:
TYPE OF STRUC � „ ,/`_-�-
7��`�' Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 ' above footing
6 '1 Vo for wet areas under slab
Backfill A royal
mg Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\lnspecdon Forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
f
/ - 3
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: �pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: &1�Aco A PERMIT#:
LOCATION: ,,� fiVe INSPECT ON: —
TYPE OF STRU
Commew
Y N NA
Footings k _
Piers
is Slabiw�' jfZ �? J
Reinforce rnt in Place A��
The-contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Roktforcemeut in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
es above footing
6 mi'1'� for wet areas under slab
Bar - val
Plumbing Under Slab i
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Fonms\Building&Codes\Inspection Fonris\Foundattlon Inspecdon Report.doc
Last printed 12/20/2005 9:24:00 AM
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart: L2-.hA11/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: 6 C PERMIT#: Off
LOCATION: "` INSPECT ON:
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings - V
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place 2 S
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection forms\Foundation Inspection Report.doc
Last printed 12/20/2005 9:24:00 AM
P fb f JAN w
�S0
4
t�S}
f
1
a
9W
�_.. ..... �. .... h t
geld x� ,
Sty r.T
rvvi d jO-oo9
J�L",vj 0� , h LfB d
J(4# rip
t-7
�E3
I
r
'Zoo
ciREScheck Software Version 4.2.4
Compliance Certificate
Project Title: COLLETTE CONSTRUCTION, INC.
Energy Code: 2000 IECC
Location: Glens Falls,New York
Construction Type: Single Family
Glazing Area Percentage: 15%
Heating Degree Days: 7635
Construction Site: Owner/Agent: Designer/Contractor:
UPPER SHERMAN AVE.
QUEENSBURY,NY
'Compliance:
Compliance:23.3%Better Than Code Maximum UA:566 Your UA:434
Gross Cavity Cont. Glazing UA
Assembly Area or R-Value R-Value or •..
Perimeter U-Factor
Ceiling 1:Flat Ceiling or Scissor Truss 1732 38.0 0.0 52
Wall 1:Wood Frame,16"o.c. 3145 19.0 0.0 158
Window 1:Vinyl Frame:Double Pane with Low-E 338 0.350 118
Door 1:Glass 120 0.350 42
Door 2:Solid 58 0A00 6
Basement Wall 1:Masonry Block with Empty Cells 458 13.0 0.0 27
Wall height:7.8'
Depth below grade:7.0
Insulation depth:7.8'
Crawl 1:Masonry Block with Empty Cells 488 13.0 0.0 31
Wall height:4.3'
Depth below grade:3.7'
Insulation depth:4.0'
Inside below-grade depth:0.3'
Furnace 1:Forced Hot Air 90 AFUE
Air Conditioner 1:Electric Central Air 13 SEER
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2000 IECC requirements in
REScheck Version 4.2.0 and to comply with the mandatory requirements listed in the REScheck inspection Checklist.
GAR-( NuCot-:5- AO 11-2(3-08
Name-Title Signature r1l Date
Project Title: COLLETTE CONSTRUCTION, INC. _a Report date: 11/20/08
Data filename: Untitled.rck Page 1 of 4
CREScheck Software Version 4.2.0
NJ( Inspection Checklist
Ceilings:
❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation
Comments:
Above-Grade Walls:
❑ Wall 1:Wood Frame,16"o.c.,R-19.0 cavity insulation
Comments:
Basement Walls:
❑ Basement Wall 1:Masonry Block with Empty Cells,7.8'ht/7.0'bg/7.8'insul,R-13.0 cavity insulation
Comments:
Windows:
❑ Window 1:Vinyl Frame:Doub(e Pane with low-E,U-factor:0.350
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break? Yes No
Comments:
Doors:
❑ Door 1:Glass,U-factor:0.350
Comments:
❑ Door 2:Solid,U-factor:0.100
Comments:
Crawl Space Walls:
❑ Crawl 1:Masonry Block with Empty Cells,4.3'ht/3.7'bg/4.0'ext.insul/0.3'inside bg depth,R-13.0 cavity insulation
Comments:
Applies to walls of unventilated crawl spaces.
Heating and Cooling Equipment:
❑ Furnace 1:Forced Hot Air:90 AFUE or higher
Make and Model Number.
❑ Air Conditioner 1:Electric Central Air:13 SEER or higher
Make and Model Number:
Air Leakage:
❑ Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed.
❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible
materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation.
Vapor Retarder:
❑ Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
Materials Identification:
❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment are identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.
❑ Insulation R-values,glazing U-factors,and heating equipment efficiency are clearly marked on the building plans or specifications.
❑ Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner
that achieves the rated R-value without compressing the insulation.
Project Title: COLLETTE CONSTRUCTION, INC. Report date: 11/20/08
Data filename: Unfitled.rck Page 2 of 4
Duct Insulation:
Ducts in unconditioned spaces are insulated to at least R-5.Ducts outside the building are insulated to at least R-8.0.
Duct Construction:
All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,or
tapes.Tapes and mastics are rated UL 181A or UL 181B.
Exceptions:
Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa).
0 The HVAC system provides a means for balancing air and water systems.
Temperature Controls:
Thermostats exist for each separate HVAC system.A manual or automatic means to partially restrict or shut off the heating and/or
cooling input to each zone or floor is provided.
Service Water Heating:
Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or
is part of a circulating system.
Lj Circulating hot water pipes are insulated to the levels in Table 1.
Circulating Hot Water Systems:
Lj Circulating hot water pipes are insulated to the levels in Table 1.
Swimming Pools:
All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable
sources.Pool pumps have a time clock.
Heating and Cooling Piping Insulation:
HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2.
oroiect Title: COLLETTE CONSTRUCTION,INC. Report date: 11/20/08
Page 3 of 4
Data filename: Untitled.rck
Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non-Circulating Runouts Circulating Mains and Runouts
Heated Water Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
Temperature(°F)
170-180 0.5 1.0 1.5 2.0
140-169 0.5 0.5 1.0 1.5
100-139 0.5 0.5 0.5 1.0
Table 2:Minimum Insulation Thickness for HVAC Pipes
Insulation Thickness in Inches by Pipe Sizes
Fluid Temp.
Piping System Types Range("F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0
Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELO:(Building Department Use Only)
Project Title:COLLETTE CONSTRUCTION, INC. Report date: 11/20/08
Data filename: Untitled.rck Page 4 of 4