Loading...
blower door resultsTesting Company: Name:LoCascio Energy Solutions Address:20 Ogden Rd. Queensbury , NEW YORK 12804 Phone: 5188573144 Technician: Name:Anthony LoCascio Credentials:HERS Rater#4242961 Email:tony@locascioenergysolutions.com Building Information: Project ID:45 smoke Address:45 Smoke Ridge Rd Queensbury, NY 12804 Geo-Tag Data:Latitude: 43.307272 Longitude: -73.699639 Timestamp: 2020-02-20 17:15:13 Customer Information: Name:Foothills Builders Address:Queensbury, NY 12804 Measured Leakage:832.9 CFM50 Test ID:45 smoke Purpose of Test:RESNET Multi-Pt Env. Leakage Measured ACH50:2.97 (+/- 0.6%)Effective Leakage Area: 40.5 in² Building Volume:16,800.0 ft³Enclosure Surface Area: 1,978.0 ft² Flow Coefficient (C):54.3 (+/- 2.8%)Exponent (n): 0.698 (+/- 0.008) Correlation Coefficient:0.99998 Test Standard:RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 62 °F Altitude: 382.0 ft Outdoor Temp: 35 °F Time Average Period: 10 seconds Test Date and Time:2020-02-26 11:19:51 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline -1.1 -60.0 -60.9 -59.8 -30.1 999.2 Ring A -48.0 -48.2 -47.1 -203.6 845.1 Ring B -35.0 -37.2 -36.1 -139.4 700.6 Ring B -23.0 -24.9 -23.8 -78.6 527.3 Ring B -10.0 -12.5 -11.4 -27.5 313.2 Ring B Test Equipment: Flow Device:Model 3 110V Fan Serial #: 3173 Custom Calibration Date: 2020-02-10 Pressure Gauge:DG1000 Serial #: 3173 Calibration Date: 2019-02-18 Deviations from Standard: None Comments: Envelope Leakage Test (Page 2) Report generated by TEC Auto Test version 1.6.3 (2), © 2019 by The Energy Conservatory, Inc.